 "pages": {
  "safety": "https://moyneross.com/technical/findings-safety",
  "failure": "https://moyneross.com/technical/findings-failure",
  "condition": "https://moyneross.com/technical/findings-condition",
  "lifecycle": "https://moyneross.com/technical/findings-lifecycle",
  "deadline": "https://moyneross.com/technical/findings-deadline",
  "check": "https://moyneross.com/technical/findings-check",
  "nil": "https://moyneross.com/technical/findings-nil"
 },
 "publisher": "Moyne Ross",
 "updatedAt": "2026-11-14",
 "gradings": {
  "safety": "Can hurt someone now. Made safe at once.",
  "failure": "Failed or failing, and damaging the building. Repaired now.",
  "condition": "Distress present and progressing. Repair programmed for the near term.",
  "lifecycle": "No current distress; renewal falls due with age and exposure.",
  "deadline": "A regulator, ordinance or order sets the date.",
  "check": "The sign calls for investigation before works can be sized.",
  "nil": "Cosmetic or stable. Routine care only."
 },
 "note": "How the library grades findings in general. A grading describes a kind of finding, never the condition of a particular building; the same sign can be graded differently once a building's own evidence is read.",
 "count": 781,
 "rows": [
  {
   "grading": "safety",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Safety edges, pans or interlocks failed or bypassed",
   "impact": "4 Essential",
   "timing": "Take out of service until proved.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-safety-edges-pans-or-interlocks-failed-or-bypass"
  },
  {
   "grading": "safety",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "No working emergency call from the platform, or no emergency lowering",
   "impact": "4 Essential",
   "timing": "Take out of service until restored.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-no-working-emergency-call-from-the-platform-or-n"
  },
  {
   "grading": "safety",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Unit or its rail obstructing an escape stair",
   "impact": "4 Essential",
   "timing": "Clear now.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-unit-or-its-rail-obstructing-an-escape-stair"
  },
  {
   "grading": "safety",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "finding": "Legionella risk from an adiabatic humidifier; heavy microbial growth in a unit serving a healthcare or occupied space; contaminated intake near a cooling tower or exhaust",
   "impact": "4 Essential",
   "timing": "Isolate or clean now; hygiene and engineer review.",
   "url": "https://moyneross.com/technical/air-handling-units#f-legionella-risk-from-an-adiabatic-humidifier-hea"
  },
  {
   "grading": "safety",
   "page": "ancillary-structures",
   "element": "Ancillary Structures",
   "section": "External Elements",
   "finding": "Leaning or damaged structures over occupied areas; damaged asbestos cement; water features with exposed electrics; bin stores against walls with fire risk",
   "impact": "4 Essential",
   "timing": "Exclude, make safe or remove now.",
   "url": "https://moyneross.com/technical/ancillary-structures#f-leaning-or-damaged-structures-over-occupied-area"
  },
  {
   "grading": "safety",
   "page": "architectural-and-decorative-features",
   "element": "Architectural & Decorative Features",
   "section": "Façades",
   "finding": "Loose, cracked or displaced ornament over a public or occupied area; recent fragments fallen",
   "impact": "4 Essential",
   "timing": "Remove loose material and protect below immediately (netting, sidewalk shed, exclusion).",
   "url": "https://moyneross.com/technical/architectural-and-decorative-features#f-loose-cracked-or-displaced-ornament-over-a-publi"
  },
  {
   "grading": "safety",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "finding": "Control valves closed; storage hazard beyond design; heads covered or obstructed over large areas; water supply below design",
   "impact": "4 Essential",
   "timing": "Restore protection or reduce the hazard now; fire watch until done.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#f-control-valves-closed-storage-hazard-beyond-desi"
  },
  {
   "grading": "safety",
   "page": "basement-cellars-and-retaining-walls",
   "element": "Basement, Cellars & Retaining Walls",
   "section": "Substructure",
   "finding": "Retaining wall leaning or moving beside a public area, building or boundary; radon above action levels",
   "impact": "4 Essential",
   "timing": "Exclude people and loads, prop or remediate now.",
   "url": "https://moyneross.com/technical/basement-cellars-and-retaining-walls#f-retaining-wall-leaning-or-moving-beside-a-public"
  },
  {
   "grading": "safety",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "finding": "Water damaging structure, electrical fittings or another dwelling; hot water above safe temperatures for vulnerable occupants",
   "impact": "4 Essential",
   "timing": "Stop use of the shower or fix now.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#f-water-damaging-structure-electrical-fittings-or"
  },
  {
   "grading": "safety",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "finding": "Structural crack, brake fault, failed safety device, or failed inspection item on equipment carrying people",
   "impact": "4 Essential",
   "timing": "Tag out of service immediately; repair before any use.",
   "url": "https://moyneross.com/technical/building-maintenance-units#f-structural-crack-brake-fault-failed-safety-devic"
  },
  {
   "grading": "safety",
   "page": "building-management-and-control-system",
   "element": "Building Management & Control System (BMCS)",
   "section": "Mechanical Services",
   "finding": "BMS exposed to the internet with default credentials; fire interface failing",
   "impact": "4 Essential",
   "timing": "Isolate and secure now; test fire interfaces.",
   "url": "https://moyneross.com/technical/building-management-and-control-system#f-bms-exposed-to-the-internet-with-default-credent"
  },
  {
   "grading": "safety",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "finding": "Sag, slack or failed rod, cracked anchorage, damaged post, or glass breakage over a footpath or entrance",
   "impact": "4 Essential",
   "timing": "Close the footpath below or prop immediately; engineer within days.",
   "url": "https://moyneross.com/technical/canopies-and-awnings#f-sag-slack-or-failed-rod-cracked-anchorage-damage"
  },
  {
   "grading": "safety",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "finding": "Ammonia or large refrigerant leak; plant room without required refrigerant detection or ventilation; pressure relief discharging into the room",
   "impact": "4 Essential",
   "timing": "Isolate and ventilate now; plant room safety measures before restart.",
   "url": "https://moyneross.com/technical/central-cooling-plant#f-ammonia-or-large-refrigerant-leak-plant-room-wit"
  },
  {
   "grading": "safety",
   "page": "central-heating-plant",
   "element": "Central Heating Plant",
   "section": "Mechanical Services",
   "finding": "Gas leak, carbon monoxide or spillage, failed flame safeguard or safety valve, inadequate plant room ventilation",
   "impact": "4 Essential",
   "timing": "Isolate now; gas fitter and engineer before restart.",
   "url": "https://moyneross.com/technical/central-heating-plant#f-gas-leak-carbon-monoxide-or-spillage-failed-flam"
  },
  {
   "grading": "safety",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Stack leaning with open joints or loose upper courses; loose pots; breast removed without support; flue gas leakage",
   "impact": "4 Essential",
   "timing": "Make safe now; appliance out of use.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-stack-leaning-with-open-joints-or-loose-upper-co"
  },
  {
   "grading": "safety",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Working flue with signs of leakage or carbon monoxide alarm activations",
   "impact": "4 Essential",
   "timing": "Take the appliance out of use until the flue is tested.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-working-flue-with-signs-of-leakage-or-carbon-mon"
  },
  {
   "grading": "safety",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Stack over a roof, path or street loose or cracked after a storm or earthquake",
   "impact": "4 Essential",
   "timing": "Make safe now.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-stack-over-a-roof-path-or-street-loose-or-cracke"
  },
  {
   "grading": "safety",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Timbers built into or touching a working flue; combustibles against an unlined flue",
   "impact": "4 Essential",
   "timing": "Take the appliance out of use until separated.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-timbers-built-into-or-touching-a-working-flue-co"
  },
  {
   "grading": "safety",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Loose, cracked or displaced panel or stone over a footpath, entry or occupied area; anchor visibly failed",
   "impact": "4 Essential",
   "timing": "Make safe immediately: remove, net or hoard; engineer within days.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-loose-cracked-or-displaced-panel-or-stone-over-a"
  },
  {
   "grading": "safety",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "finding": "Grease build-up in ducts; suppression not covering appliances; gas interlocks bypassed; cool room releases failed; CO from backdraught",
   "impact": "4 Essential",
   "timing": "Rectify before cooking continues.",
   "url": "https://moyneross.com/technical/commercial-kitchens#f-grease-build-up-in-ducts-suppression-not-coverin"
  },
  {
   "grading": "safety",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "finding": "Rooms without required sprinkler, detection, emergency lighting or exit coverage; egress paths blocked by the fit-out",
   "impact": "4 Essential",
   "timing": "Rectify before occupation continues.",
   "url": "https://moyneross.com/technical/commercial-office-areas#f-rooms-without-required-sprinkler-detection-emerg"
  },
  {
   "grading": "safety",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "finding": "Obstructed escape routes; fire doors not closing; failed emergency lighting; smoke vents not opening",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/common-circulation-areas#f-obstructed-escape-routes-fire-doors-not-closing"
  },
  {
   "grading": "safety",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "finding": "Non-compliant flat entrance doors; storage and charging in escape routes; failed emergency lighting",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/common-internal-areas#f-non-compliant-flat-entrance-doors-storage-and-ch"
  },
  {
   "grading": "safety",
   "page": "communications-security-and-specialist-systems",
   "element": "Communications, Security & Specialist Systems",
   "section": "Electrical Services",
   "finding": "Lift emergency phones or alarm diallers not working; access-controlled escape doors not releasing; nurse call failures",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/communications-security-and-specialist-systems#f-lift-emergency-phones-or-alarm-diallers-not-work"
  },
  {
   "grading": "safety",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "finding": "Lifted tactile indicators or damaged ramps creating trip hazards; no means of evacuation for people with disability",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/disabled-access#f-lifted-tactile-indicators-or-damaged-ramps-creat"
  },
  {
   "grading": "safety",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Free-fall protection failed or absent on a leveller in use",
   "impact": "4 Essential",
   "timing": "Take out of use now; this is the failure that kills.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-free-fall-protection-failed-or-absent-on-a-level"
  },
  {
   "grading": "safety",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Goods hoist landing door opening without the car present",
   "impact": "4 Essential",
   "timing": "Take out of use until the interlock is proved.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-goods-hoist-landing-door-opening-without-the-car"
  },
  {
   "grading": "safety",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Cracked lips, decks or hinges under load",
   "impact": "4 Essential",
   "timing": "Take out of use now.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-cracked-lips-decks-or-hinges-under-load"
  },
  {
   "grading": "safety",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Open dock edges with no barrier, gate or closed door",
   "impact": "4 Essential",
   "timing": "Protect now.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-open-dock-edges-with-no-barrier-gate-or-closed-d"
  },
  {
   "grading": "safety",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "No vehicle restraint or chocking in use at an operating dock",
   "impact": "4 Essential",
   "timing": "Stop loading until a restraint procedure is in place.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-no-vehicle-restraint-or-chocking-in-use-at-an-op"
  },
  {
   "grading": "safety",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Staff riding a goods hoist",
   "impact": "4 Essential",
   "timing": "Stop now; signage alone is not a control.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-staff-riding-a-goods-hoist"
  },
  {
   "grading": "safety",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "finding": "Fire or smoke dampers missing, obstructed, failed or untested; deteriorating asbestos in duct materials",
   "impact": "4 Essential",
   "timing": "Rectify now; fire engineer and licensed asbestos removal.",
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#f-fire-or-smoke-dampers-missing-obstructed-failed"
  },
  {
   "grading": "safety",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "finding": "Overloaded circuits or boards; unsafe installations; extension-lead charging",
   "impact": "4 Essential",
   "timing": "Isolate and rectify now.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#f-overloaded-circuits-or-boards-unsafe-installatio"
  },
  {
   "grading": "safety",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "finding": "Unsealed riser floors; storage in risers; water on electrical equipment",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#f-unsealed-riser-floors-storage-in-risers-water-on"
  },
  {
   "grading": "safety",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "finding": "Escape routes, stairs or exits without working emergency lighting or exit signs; fittings that will not operate on local failure",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/emergency-lighting#f-escape-routes-stairs-or-exits-without-working-em"
  },
  {
   "grading": "safety",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "finding": "Generator serving life-safety loads fails to start or carry load; fuel leak; lithium battery fire risk without separation",
   "impact": "4 Essential",
   "timing": "Rectify now; interim measures.",
   "url": "https://moyneross.com/technical/emergency-power#f-generator-serving-life-safety-loads-fails-to-sta"
  },
  {
   "grading": "safety",
   "page": "energy-efficiency-upgrades",
   "element": "Energy Efficiency Upgrades",
   "section": "Environmental",
   "finding": "Fabric upgrade causing condensation and mould affecting health",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/energy-efficiency-upgrades#f-fabric-upgrade-causing-condensation-and-mould-af"
  },
  {
   "grading": "safety",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Safety devices bypassed, disconnected or failing on test",
   "impact": "4 Essential",
   "timing": "Stop the unit until every device is proved.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-safety-devices-bypassed-disconnected-or-failing"
  },
  {
   "grading": "safety",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Broken comb teeth; step to skirt gaps beyond limit; missing skirt deflectors",
   "impact": "4 Essential",
   "timing": "Stop until fixed.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-broken-comb-teeth-step-to-skirt-gaps-beyond-limi"
  },
  {
   "grading": "safety",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Brake out of its stopping distance limits, or auxiliary brake defective",
   "impact": "4 Essential",
   "timing": "Stop until adjusted and retested.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-brake-out-of-its-stopping-distance-limits-or-aux"
  },
  {
   "grading": "safety",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Handrail speed mismatch, cracked handrail or missing inlet guard",
   "impact": "4 Essential",
   "timing": "Stop or restrict until corrected.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-handrail-speed-mismatch-cracked-handrail-or-miss"
  },
  {
   "grading": "safety",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Cracked or broken steps, or missing demarcation lines",
   "impact": "4 Essential",
   "timing": "Stop until replaced.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-cracked-or-broken-steps-or-missing-demarcation-l"
  },
  {
   "grading": "safety",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "finding": "Loose render over a public or occupied area; deteriorating lead paint where children live or play",
   "impact": "4 Essential",
   "timing": "Remove loose render and protect below; stabilise lead paint under controls immediately.",
   "url": "https://moyneross.com/technical/external-coating-systems#f-loose-render-over-a-public-or-occupied-area-dete"
  },
  {
   "grading": "safety",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "finding": "Powered gate safety devices failing; pool barrier non-compliant; boundary wall leaning toward a public area; exit signs wrong or missing",
   "impact": "4 Essential",
   "timing": "Disable, close or rectify now.",
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#f-powered-gate-safety-devices-failing-pool-barrier"
  },
  {
   "grading": "safety",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "finding": "Zones isolated or detectors covered in occupied areas; alarm signalling not reaching the brigade; inaudible warning; failed interfaces to lifts, doors or smoke control",
   "impact": "4 Essential",
   "timing": "Restore protection now; fire watch until done.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#f-zones-isolated-or-detectors-covered-in-occupied"
  },
  {
   "grading": "safety",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "finding": "Pump fails to start; controller in off or manual; pump supply unprotected; performance well below design",
   "impact": "4 Essential",
   "timing": "Restore now; fire watch and brigade notification.",
   "url": "https://moyneross.com/technical/fire-pumping-systems#f-pump-fails-to-start-controller-in-off-or-manual"
  },
  {
   "grading": "safety",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "finding": "Carbon monoxide or spillage; inadequate clearances; unflued heaters in bedrooms",
   "impact": "4 Essential",
   "timing": "Stop use now.",
   "url": "https://moyneross.com/technical/fireplaces#f-carbon-monoxide-or-spillage-inadequate-clearance"
  },
  {
   "grading": "safety",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "finding": "Trip hazards; slippery floors with incidents; damaged asbestos-containing tiles",
   "impact": "4 Essential",
   "timing": "Make safe now.",
   "url": "https://moyneross.com/technical/flooring#f-trip-hazards-slippery-floors-with-incidents-dama"
  },
  {
   "grading": "safety",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "finding": "Rapid or large movement with wide cracks, distorted openings that threaten egress, or loss of bearing to walls and columns",
   "impact": "4 Essential",
   "timing": "Prop and engineer now.",
   "url": "https://moyneross.com/technical/foundations#f-rapid-or-large-movement-with-wide-cracks-distort"
  },
  {
   "grading": "safety",
   "page": "gas-services",
   "element": "Gas Services",
   "section": "Hydraulic Services",
   "finding": "Gas leak; uncapped live pipe; failed emergency shut-off; LPG separation breached",
   "impact": "4 Essential",
   "timing": "Isolate and rectify now.",
   "url": "https://moyneross.com/technical/gas-services#f-gas-leak-uncapped-live-pipe-failed-emergency-shu"
  },
  {
   "grading": "safety",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "finding": "Broken or loose glass at height over a public or occupied area; SSG glass moving; spontaneous breakage of non-heat-soaked toughened glass above a footpath",
   "impact": "4 Essential",
   "timing": "Make safe immediately: remove, protect below, restrict access; engineer and glazier within days.",
   "url": "https://moyneross.com/technical/glazing-systems#f-broken-or-loose-glass-at-height-over-a-public-or"
  },
  {
   "grading": "safety",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "finding": "Damaged friable asbestos in accessible areas; deteriorating lead paint where children are present; leaking PCBs",
   "impact": "4 Essential",
   "timing": "Isolate and remediate now.",
   "url": "https://moyneross.com/technical/hazardous-materials#f-damaged-friable-asbestos-in-accessible-areas-det"
  },
  {
   "grading": "safety",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "finding": "Legionella above the action levels in the regulation; tower near air intakes or public areas with damaged drift eliminators",
   "impact": "4 Essential",
   "timing": "Disinfect and follow the prescribed response now.",
   "url": "https://moyneross.com/technical/heat-rejection-plant#f-legionella-above-the-action-levels-in-the-regula"
  },
  {
   "grading": "safety",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "finding": "Failed TMVs in healthcare, aged care, childcare or accessible bathrooms; positive Legionella; relief valve blocked; gas heater flue spillage",
   "impact": "4 Essential",
   "timing": "Isolate, disinfect or rectify now.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#f-failed-tmvs-in-healthcare-aged-care-childcare-or"
  },
  {
   "grading": "safety",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "finding": "Booster or hydrants inaccessible or inoperable; dry riser failing pressure test; flow well below requirement",
   "impact": "4 Essential",
   "timing": "Restore now; notify the brigade.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#f-booster-or-hydrants-inaccessible-or-inoperable-d"
  },
  {
   "grading": "safety",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Loose-fill asbestos; foil over damaged wiring; batts over downlights or transformers",
   "impact": "4 Essential",
   "timing": "Isolate and assess now; do not disturb.",
   "url": "https://moyneross.com/technical/insulation#f-loose-fill-asbestos-foil-over-damaged-wiring-bat"
  },
  {
   "grading": "safety",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "finding": "Fire interfaces failing (AHUs, smoke control, lifts, doors, gas)",
   "impact": "4 Essential",
   "timing": "Rectify now; fire watch if needed.",
   "url": "https://moyneross.com/technical/integrated-building-systems#f-fire-interfaces-failing-ahus-smoke-control-lifts"
  },
  {
   "grading": "safety",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "finding": "Exit doors locked or with wrong hardware; electronic locks not releasing; fire doors not closing",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#f-exit-doors-locked-or-with-wrong-hardware-electro"
  },
  {
   "grading": "safety",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "finding": "Propped or failed stair doors; storage in stairs; failed emergency lighting; locked final exits; unsafe locking",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/internal-stairwells#f-propped-or-failed-stair-doors-storage-in-stairs"
  },
  {
   "grading": "safety",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "finding": "Sagging ceilings; damaged asbestos-containing finishes; flaking lead paint where children are present",
   "impact": "4 Essential",
   "timing": "Exclude, make safe and remediate now.",
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#f-sagging-ceilings-damaged-asbestos-containing-fin"
  },
  {
   "grading": "safety",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "finding": "Gas leaks or unsafe clearances; aged flexible hoses; overloaded circuits",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/kitchen#f-gas-leaks-or-unsafe-clearances-aged-flexible-hos"
  },
  {
   "grading": "safety",
   "page": "landscaping-and-irrigation",
   "element": "Landscaping & Irrigation",
   "section": "External Elements",
   "finding": "Defective trees over occupied areas; vegetation creating bushfire risk",
   "impact": "4 Essential",
   "timing": "Prune, remove or exclude now.",
   "url": "https://moyneross.com/technical/landscaping-and-irrigation#f-defective-trees-over-occupied-areas-vegetation-c"
  },
  {
   "grading": "safety",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "finding": "Water in pits affecting safety equipment; machine rooms with unsafe access or storage",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#f-water-in-pits-affecting-safety-equipment-machine"
  },
  {
   "grading": "safety",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "finding": "Columns corroded or damaged at the base; suspended fittings with failed fixings; leaking PCB capacitors",
   "impact": "4 Essential",
   "timing": "Remove, secure or isolate now.",
   "url": "https://moyneross.com/technical/lighting#f-columns-corroded-or-damaged-at-the-base-suspende"
  },
  {
   "grading": "safety",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "finding": "Stairs or egress paths left dark by sensor faults or settings",
   "impact": "4 Essential",
   "timing": "Fix now.",
   "url": "https://moyneross.com/technical/lighting-control-system#f-stairs-or-egress-paths-left-dark-by-sensor-fault"
  },
  {
   "grading": "safety",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "finding": "Loose conductors at height over public areas; protection missing on hazardous stores",
   "impact": "4 Essential",
   "timing": "Secure or rectify now.",
   "url": "https://moyneross.com/technical/lightning-protection#f-loose-conductors-at-height-over-public-areas-pro"
  },
  {
   "grading": "safety",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "finding": "Walls bowing significantly; crushed bearings under beams; bulging stone faces; unreinforced masonry parapets in seismic areas",
   "impact": "4 Essential",
   "timing": "Prop and engineer now.",
   "url": "https://moyneross.com/technical/load-bearing-masonry#f-walls-bowing-significantly-crushed-bearings-unde"
  },
  {
   "grading": "safety",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "finding": "No pedestrian segregation; dock doors with failed safety devices or springs; open edges; fumes entering the building",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#f-no-pedestrian-segregation-dock-doors-with-failed"
  },
  {
   "grading": "safety",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "finding": "Non-laminated overhead glass over occupied areas with breakage history; low or climbable balustrades at upper levels; smoke control failing tests",
   "impact": "4 Essential",
   "timing": "Protect, restrict access or rectify now.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#f-non-laminated-overhead-glass-over-occupied-areas"
  },
  {
   "grading": "safety",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "finding": "Cracked heat exchanger on a gas rooftop unit; refrigerant leak in a small room without detection",
   "impact": "4 Essential",
   "timing": "Isolate now.",
   "url": "https://moyneross.com/technical/localised-hvac#f-cracked-heat-exchanger-on-a-gas-rooftop-unit-ref"
  },
  {
   "grading": "safety",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "finding": "Exposed live parts; burning or overheating; water on or above the board; PCB oil leaking",
   "impact": "4 Essential",
   "timing": "Isolate or protect now.",
   "url": "https://moyneross.com/technical/main-electrical-supply#f-exposed-live-parts-burning-or-overheating-water"
  },
  {
   "grading": "safety",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "finding": "Unsafe automatic or revolving doors; slippery entry with incidents; security that does not release on alarm",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#f-unsafe-automatic-or-revolving-doors-slippery-ent"
  },
  {
   "grading": "safety",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "finding": "Unidentified confined spaces; unguarded hatches; no safe access to plant above ceilings or on roofs",
   "impact": "4 Essential",
   "timing": "Rectify before next access.",
   "url": "https://moyneross.com/technical/maintenance-access-areas#f-unidentified-confined-spaces-unguarded-hatches-n"
  },
  {
   "grading": "safety",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "finding": "Loose, displaced or bulging brickwork over a footpath, entrance or occupied area; parapet or chimney out of plumb; outer leaf detached from ties",
   "impact": "4 Essential",
   "timing": "Make safe immediately (exclusion zone, netting or take-down), engineer within days, repair within months.",
   "url": "https://moyneross.com/technical/masonry-brickwork#f-loose-displaced-or-bulging-brickwork-over-a-foot"
  },
  {
   "grading": "safety",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "finding": "Unprotected access to plant at height; unidentified confined spaces; dangerous glazing; slippery entries",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#f-unprotected-access-to-plant-at-height-unidentifi"
  },
  {
   "grading": "safety",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "finding": "Fire-rated partitions breached; unsafe glazing; operable walls with failing tracks",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/partitioning-systems#f-fire-rated-partitions-breached-unsafe-glazing-op"
  },
  {
   "grading": "safety",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Landing door openable without the car present; car moves with doors open; brake or safety gear defect",
   "impact": "4 Essential",
   "timing": "Remove from service until fixed.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-landing-door-openable-without-the-car-present-ca"
  },
  {
   "grading": "safety",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Emergency communication not working, or reaching no one who answers",
   "impact": "4 Essential",
   "timing": "Remove from service until restored.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-emergency-communication-not-working-or-reaching"
  },
  {
   "grading": "safety",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Levelling errors creating a trip step at a landing",
   "impact": "4 Essential",
   "timing": "Correct now; restrict use if significant.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-levelling-errors-creating-a-trip-step-at-a-landi"
  },
  {
   "grading": "safety",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Fire-fighting or evacuation lift not performing its fire functions",
   "impact": "4 Essential",
   "timing": "Restore now; notify the fire strategy owner.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-fire-fighting-or-evacuation-lift-not-performing"
  },
  {
   "grading": "safety",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "finding": "Stair or escape route doors not closing; breached riser or stair penetrations; fire doors wedged open; flat entrance doors not fire-rated in apartment buildings",
   "impact": "4 Essential",
   "timing": "Rectify now; fire watch or interim measures where needed.",
   "url": "https://moyneross.com/technical/passive-fire-protection#f-stair-or-escape-route-doors-not-closing-breached"
  },
  {
   "grading": "safety",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "finding": "Trip hazards in pedestrian routes; large potholes in traffic areas",
   "impact": "4 Essential",
   "timing": "Make safe now: patch, grind or barricade.",
   "url": "https://moyneross.com/technical/pavements-and-hardstand#f-trip-hazards-in-pedestrian-routes-large-potholes"
  },
  {
   "grading": "safety",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "finding": "Failed refrigerant or gas detection; blocked exits; storage at switchboards; water over switchboards",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/plant-rooms#f-failed-refrigerant-or-gas-detection-blocked-exit"
  },
  {
   "grading": "safety",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Parapet leaning or bowing over a public area; loose copings; screens loose",
   "impact": "4 Essential",
   "timing": "Make safe now: remove, restrain or exclude below.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-parapet-leaning-or-bowing-over-a-public-area-loo"
  },
  {
   "grading": "safety",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Loose copings or screen panels over a street or entrance",
   "impact": "4 Essential",
   "timing": "Secure or remove now.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-loose-copings-or-screen-panels-over-a-street-or"
  },
  {
   "grading": "safety",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Terracotta or ornament with corroded cramps, units loose or cracked, over a street",
   "impact": "4 Essential",
   "timing": "Make safe now: remove loose units, net or hoard below.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-terracotta-or-ornament-with-corroded-cramps-unit"
  },
  {
   "grading": "safety",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "finding": "Wrong type at a high hazard (water at switchboards, none at commercial cooking); discharged units in high-risk areas",
   "impact": "4 Essential",
   "timing": "Replace now.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#f-wrong-type-at-a-high-hazard-water-at-switchboard"
  },
  {
   "grading": "safety",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "finding": "Perished rubber wiring; exposed live parts; scorched accessories; no RCD on wet area or outdoor circuits; aluminium branch wiring without remediation",
   "impact": "4 Essential",
   "timing": "Isolate, make safe or rewire now.",
   "url": "https://moyneross.com/technical/power-distribution#f-perished-rubber-wiring-exposed-live-parts-scorch"
  },
  {
   "grading": "safety",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "finding": "Legionella risk from little-used showers; accessible facilities unavailable",
   "impact": "4 Essential",
   "timing": "Flush, disinfect, restore now.",
   "url": "https://moyneross.com/technical/public-amenities#f-legionella-risk-from-little-used-showers-accessi"
  },
  {
   "grading": "safety",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "finding": "Sump serving switchrooms or lift pits with failed pumps or alarms; sewage pit with no ventilation or failed lid",
   "impact": "4 Essential",
   "timing": "Restore now; temporary pumping.",
   "url": "https://moyneross.com/technical/pumping-systems#f-sump-serving-switchrooms-or-lift-pits-with-faile"
  },
  {
   "grading": "safety",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Ponding on a light roof with visible deflection; blocked outlets with water building against a parapet",
   "impact": "4 Essential",
   "timing": "Clear and relieve now; stop access.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-ponding-on-a-light-roof-with-visible-deflection"
  },
  {
   "grading": "safety",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Gutters, brackets or cast iron loose over entrances and paths",
   "impact": "4 Essential",
   "timing": "Secure or remove now.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-gutters-brackets-or-cast-iron-loose-over-entranc"
  },
  {
   "grading": "safety",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Internal stack or gutter leaking near switchboards, risers or electrical equipment",
   "impact": "4 Essential",
   "timing": "Isolate and repair now.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-internal-stack-or-gutter-leaking-near-switchboar"
  },
  {
   "grading": "safety",
   "page": "recreational-facilities",
   "element": "Recreational Facilities",
   "section": "External Elements",
   "finding": "Inadequate surfacing; entrapment hazards; broken equipment; gas leaks",
   "impact": "4 Essential",
   "timing": "Close and fix now.",
   "url": "https://moyneross.com/technical/recreational-facilities#f-inadequate-surfacing-entrapment-hazards-broken-e"
  },
  {
   "grading": "safety",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "finding": "Missing or failed smoke alarms; entry doors not self-closing in apartment buildings; severe mould",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#f-missing-or-failed-smoke-alarms-entry-doors-not-s"
  },
  {
   "grading": "safety",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "finding": "Fire separation breached between tenancies; sprinkler or detection coverage missing after fit-out",
   "impact": "4 Essential",
   "timing": "Rectify before trading continues.",
   "url": "https://moyneross.com/technical/retail-tenancies#f-fire-separation-breached-between-tenancies-sprin"
  },
  {
   "grading": "safety",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Fragile roof (asbestos cement, translucent sheet) reached without walkways, mesh or edge protection",
   "impact": "4 Essential",
   "timing": "Stop access until controls are in place.",
   "url": "https://moyneross.com/technical/roof-coverings#f-fragile-roof-access"
  },
  {
   "grading": "safety",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Loose sheets, tiles, cappings or flashings above a footpath or entrance",
   "impact": "4 Essential",
   "timing": "Secure or remove now.",
   "url": "https://moyneross.com/technical/roof-coverings#f-loose-material-over-people"
  },
  {
   "grading": "safety",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Plant, gutters or roof lights maintained near an unprotected edge or fragile surface",
   "impact": "4 Essential",
   "timing": "Stop access until protected.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-plant-gutters-or-roof-lights-maintained-near-an"
  },
  {
   "grading": "safety",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Fragile roof lights or sheeting on access routes with no mesh, covers or guardrails",
   "impact": "4 Essential",
   "timing": "Protect or bar access now.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-fragile-roof-lights-or-sheeting-on-access-routes"
  },
  {
   "grading": "safety",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Visible sag with cracking, buckled members or failed connections; RAAC planks showing cracking, deflection or wet",
   "impact": "4 Essential",
   "timing": "Prop and restrict use now.",
   "url": "https://moyneross.com/technical/roof-structure#f-visible-sag-with-cracking-buckled-members-or-fai"
  },
  {
   "grading": "safety",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Ponding on a light roof with visible deflection",
   "impact": "4 Essential",
   "timing": "Relieve the water and restrict access now.",
   "url": "https://moyneross.com/technical/roof-structure#f-ponding-on-a-light-roof-with-visible-deflection"
  },
  {
   "grading": "safety",
   "page": "sanitary-and-drainage-systems",
   "element": "Sanitary & Drainage Systems",
   "section": "Hydraulic Services",
   "finding": "Sewage leaking into occupied spaces; sewer gas in occupied rooms; no backflow protection in flood-prone basements",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/sanitary-and-drainage-systems#f-sewage-leaking-into-occupied-spaces-sewer-gas-in"
  },
  {
   "grading": "safety",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "finding": "Sealant or panels so failed that cladding or glazing is loose",
   "impact": "4 Essential",
   "timing": "Make safe now.",
   "url": "https://moyneross.com/technical/sealants-and-joints#f-sealant-or-panels-so-failed-that-cladding-or-gla"
  },
  {
   "grading": "safety",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "finding": "Exits blocked; exit doors locked; fire doors propped",
   "impact": "4 Essential",
   "timing": "Clear and rectify now.",
   "url": "https://moyneross.com/technical/service-corridors#f-exits-blocked-exit-doors-locked-fire-doors-propp"
  },
  {
   "grading": "safety",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Unprotected fragile roof lights where people work; overhead glass that is not laminated over occupied areas, with breakage history",
   "impact": "4 Essential",
   "timing": "Protect now: mesh, covers, guardrails or restrict access.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-unprotected-fragile-roof-lights-where-people-wor"
  },
  {
   "grading": "safety",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Monolithic toughened or wired glass in overhead positions above occupied space",
   "impact": "4 Essential",
   "timing": "Protect below or replace with laminated glass.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-monolithic-toughened-or-wired-glass-in-overhead"
  },
  {
   "grading": "safety",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "finding": "Trip edges in walkways; settlement under racking causing lean; damaged post-tensioning",
   "impact": "4 Essential",
   "timing": "Isolate area and fix now.",
   "url": "https://moyneross.com/technical/slab-on-ground#f-trip-edges-in-walkways-settlement-under-racking"
  },
  {
   "grading": "safety",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "finding": "System does not start on alarm; stair doors cannot be opened; stair pressurisation failed; AOVs not opening",
   "impact": "4 Essential",
   "timing": "Rectify now; interim measures.",
   "url": "https://moyneross.com/technical/smoke-management-systems#f-system-does-not-start-on-alarm-stair-doors-canno"
  },
  {
   "grading": "safety",
   "page": "solar-photovoltaic-systems",
   "element": "Solar Photovoltaic (PV) Systems",
   "section": "Electrical Services",
   "finding": "Burnt connectors or isolators; exposed live DC; loose modules; battery overheating",
   "impact": "4 Essential",
   "timing": "Isolate now.",
   "url": "https://moyneross.com/technical/solar-photovoltaic-systems#f-burnt-connectors-or-isolators-exposed-live-dc-lo"
  },
  {
   "grading": "safety",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "finding": "Fume cupboards failing containment; untested or blocked safety showers; medical gas faults; ligature points in mental health areas",
   "impact": "4 Essential",
   "timing": "Take out of use and rectify now.",
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#f-fume-cupboards-failing-containment-untested-or-b"
  },
  {
   "grading": "safety",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "finding": "Electrical hazards near water; overloaded floors; pool and spa safety failures",
   "impact": "4 Essential",
   "timing": "Isolate now.",
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#f-electrical-hazards-near-water-overloaded-floors"
  },
  {
   "grading": "safety",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "finding": "Unsafe pool outlets; pool barriers failed; chemical storage able to release chlorine gas; cross-connection to drinking water; Legionella in a spa or feature",
   "impact": "4 Essential",
   "timing": "Close, isolate or rectify now.",
   "url": "https://moyneross.com/technical/specialist-hydraulics#f-unsafe-pool-outlets-pool-barriers-failed-chemica"
  },
  {
   "grading": "safety",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "Carbon dioxide safeguards failed; system isolated in a protected room; kitchen system disabled",
   "impact": "4 Essential",
   "timing": "Rectify now.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-carbon-dioxide-safeguards-failed-system-isolated"
  },
  {
   "grading": "safety",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "finding": "Floor overload; incompatible dangerous goods; storage blocking sprinklers or egress; battery charging in cages",
   "impact": "4 Essential",
   "timing": "Remove or rectify now.",
   "url": "https://moyneross.com/technical/storage-and-archive-areas#f-floor-overload-incompatible-dangerous-goods-stor"
  },
  {
   "grading": "safety",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "finding": "Broken or missing grates in traffic or pedestrian areas; flooding into switchrooms or basements",
   "impact": "4 Essential",
   "timing": "Make safe now.",
   "url": "https://moyneross.com/technical/stormwater-drainage#f-broken-or-missing-grates-in-traffic-or-pedestria"
  },
  {
   "grading": "safety",
   "page": "structural-core",
   "element": "Structural Core",
   "section": "Superstructure",
   "finding": "Bracing removed in a portal frame building; significant openings in cores without engineering; earthquake damage",
   "impact": "4 Essential",
   "timing": "Brace temporarily and engineer now.",
   "url": "https://moyneross.com/technical/structural-core#f-bracing-removed-in-a-portal-frame-building-signi"
  },
  {
   "grading": "safety",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "finding": "Punching shear distress; significant section loss at critical members; spalling over occupied areas; post-fire damage",
   "impact": "4 Essential",
   "timing": "Prop, exclude and engineer now.",
   "url": "https://moyneross.com/technical/structural-frame#f-punching-shear-distress-significant-section-loss"
  },
  {
   "grading": "safety",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "finding": "Floor collapse risk from decay or termites; radon above action levels",
   "impact": "4 Essential",
   "timing": "Prop and remediate now.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#f-floor-collapse-risk-from-decay-or-termites-radon"
  },
  {
   "grading": "safety",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "finding": "Water leaking onto electrical equipment; asbestos in deteriorating induction units",
   "impact": "4 Essential",
   "timing": "Isolate now.",
   "url": "https://moyneross.com/technical/terminal-units#f-water-leaking-onto-electrical-equipment-asbestos"
  },
  {
   "grading": "safety",
   "page": "trade-waste-systems",
   "element": "Trade Waste Systems",
   "section": "Hydraulic Services",
   "finding": "Broken covers in trafficked areas; hydrogen sulphide exposure; oil discharging to stormwater",
   "impact": "4 Essential",
   "timing": "Make safe and contain now.",
   "url": "https://moyneross.com/technical/trade-waste-systems#f-broken-covers-in-trafficked-areas-hydrogen-sulph"
  },
  {
   "grading": "safety",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "finding": "Floors overloaded beyond design; cut tendons; severe decay at joist bearings",
   "impact": "4 Essential",
   "timing": "Remove loads or prop now.",
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#f-floors-overloaded-beyond-design-cut-tendons-seve"
  },
  {
   "grading": "safety",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "finding": "Grease build-up in kitchen ductwork; car park ventilation not responding to CO; fume cupboard failing test; flue spillage from negative pressure",
   "impact": "4 Essential",
   "timing": "Stop use or clean and repair now.",
   "url": "https://moyneross.com/technical/ventilation-systems#f-grease-build-up-in-kitchen-ductwork-car-park-ven"
  },
  {
   "grading": "safety",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Balustrade that moves under hand pressure, missing glass panel, loose post; cantilever rotation or root cracking; decayed or loose deck ledger",
   "impact": "4 Essential",
   "timing": "Close or barricade immediately; engineer within days.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-balustrade-that-moves-under-hand-pressure-missin"
  },
  {
   "grading": "safety",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Cantilever tip dropped with cracking along the wall line; deck ledger separating from the wall",
   "impact": "4 Essential",
   "timing": "Close the balcony or deck now and prop.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-cantilever-tip-dropped-with-cracking-along-the-w"
  },
  {
   "grading": "safety",
   "page": "water-conservation",
   "element": "Water Conservation",
   "section": "Environmental",
   "finding": "Cross-connection of recycled water to drinking water",
   "impact": "4 Essential",
   "timing": "Isolate now.",
   "url": "https://moyneross.com/technical/water-conservation#f-cross-connection-of-recycled-water-to-drinking-w"
  },
  {
   "grading": "safety",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "finding": "Failed backflow device on a high-hazard connection; unprotected cross-connection; lead above drinking water limits; Legionella in cold storage",
   "impact": "4 Essential",
   "timing": "Isolate or rectify now; notify the utility or health authority where required.",
   "url": "https://moyneross.com/technical/water-supply#f-failed-backflow-device-on-a-high-hazard-connecti"
  },
  {
   "grading": "safety",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Membrane torn or lifted by wind; ballast displaced at corners and edges over public areas",
   "impact": "4 Essential",
   "timing": "Secure now.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-membrane-torn-or-lifted-by-wind-ballast-displace"
  },
  {
   "grading": "safety",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Ponding on a light deck with visible deflection; outlets blocked with water rising",
   "impact": "4 Essential",
   "timing": "Clear and relieve now.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-ponding-on-a-light-deck-with-visible-deflection"
  },
  {
   "grading": "failure",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Unit out of service, leaving no step-free route between the levels",
   "impact": "4 Essential",
   "timing": "Restore now, or provide a managed alternative route in the meantime.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-unit-out-of-service-leaving-no-step-free-route-b"
  },
  {
   "grading": "failure",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Repeated long outages amounting to a significant share of the year",
   "impact": "4 Essential",
   "timing": "Treat as an access failure; plan replacement.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-repeated-long-outages-amounting-to-a-significant"
  },
  {
   "grading": "failure",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "finding": "Unit failed serving an occupied or critical space; major leaks",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/air-handling-units#f-unit-failed-serving-an-occupied-or-critical-spac"
  },
  {
   "grading": "failure",
   "page": "ancillary-structures",
   "element": "Ancillary Structures",
   "section": "External Elements",
   "finding": "Structure collapsed or unusable",
   "impact": "2 Planned",
   "timing": "Remove or rebuild.",
   "url": "https://moyneross.com/technical/ancillary-structures#f-structure-collapsed-or-unusable"
  },
  {
   "grading": "failure",
   "page": "architectural-and-decorative-features",
   "element": "Architectural & Decorative Features",
   "section": "Façades",
   "finding": "Stone, terracotta or render units detached or falling",
   "impact": "4 Essential",
   "timing": "Make safe now; public protection until repaired.",
   "url": "https://moyneross.com/technical/architectural-and-decorative-features#f-stone-terracotta-or-render-units-detached-or-fal"
  },
  {
   "grading": "failure",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "finding": "Leaks causing damage; system out of service",
   "impact": "4 Essential",
   "timing": "Repair now with impairment management.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#f-leaks-causing-damage-system-out-of-service"
  },
  {
   "grading": "failure",
   "page": "basement-cellars-and-retaining-walls",
   "element": "Basement, Cellars & Retaining Walls",
   "section": "Substructure",
   "finding": "Basement flooding; wall collapse",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/basement-cellars-and-retaining-walls#f-basement-flooding-wall-collapse"
  },
  {
   "grading": "failure",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "finding": "Active leak to the unit below; rotted floor",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#f-active-leak-to-the-unit-below-rotted-floor"
  },
  {
   "grading": "failure",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "finding": "Equipment out of service with façade maintenance stopped; anchors uncertified",
   "impact": "4 Essential",
   "timing": "Restore now or arrange alternative access; façade inspections and cleaning depend on it.",
   "url": "https://moyneross.com/technical/building-maintenance-units#f-equipment-out-of-service-with-fa-ade-maintenance"
  },
  {
   "grading": "failure",
   "page": "building-management-and-control-system",
   "element": "Building Management & Control System (BMCS)",
   "section": "Mechanical Services",
   "finding": "Head end or controllers failed, plant uncontrolled",
   "impact": "3 Important",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/building-management-and-control-system#f-head-end-or-controllers-failed-plant-uncontrolle"
  },
  {
   "grading": "failure",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "finding": "Ponding on the roof with deflection",
   "impact": "4 Essential",
   "timing": "Clear and relieve the load now; engineer to assess.",
   "url": "https://moyneross.com/technical/canopies-and-awnings#f-ponding-on-the-roof-with-deflection"
  },
  {
   "grading": "failure",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "finding": "Chiller failed with no standby capacity in a building that needs cooling (hospital, data, summer occupancy)",
   "impact": "3 Important",
   "timing": "Restore or hire temporary plant now.",
   "url": "https://moyneross.com/technical/central-cooling-plant#f-chiller-failed-with-no-standby-capacity-in-a-bui"
  },
  {
   "grading": "failure",
   "page": "central-heating-plant",
   "element": "Central Heating Plant",
   "section": "Mechanical Services",
   "finding": "No heating in winter in residential, healthcare or education buildings; major leaks",
   "impact": "3 Important",
   "timing": "Restore now or provide temporary heat.",
   "url": "https://moyneross.com/technical/central-heating-plant#f-no-heating-in-winter-in-residential-healthcare-o"
  },
  {
   "grading": "failure",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Water entering the building through the stack",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-water-entering-the-building-through-the-stack"
  },
  {
   "grading": "failure",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Decay or corrosion found in framing or sheathing behind a face-sealed system",
   "impact": "3 Important",
   "timing": "Remediation now; extent from opening up, often elevation by elevation.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-decay-or-corrosion-found-in-framing-or-sheathing"
  },
  {
   "grading": "failure",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "finding": "Exhaust or refrigeration failed",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/commercial-kitchens#f-exhaust-or-refrigeration-failed"
  },
  {
   "grading": "failure",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "finding": "Leaks damaging finishes and services; air conditioning failed on a floor",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/commercial-office-areas#f-leaks-damaging-finishes-and-services-air-conditi"
  },
  {
   "grading": "failure",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "finding": "Corridor lighting failed",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/common-circulation-areas#f-corridor-lighting-failed"
  },
  {
   "grading": "failure",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "finding": "Intercom or entry security failed",
   "impact": "3 Important",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/common-internal-areas#f-intercom-or-entry-security-failed"
  },
  {
   "grading": "failure",
   "page": "communications-security-and-specialist-systems",
   "element": "Communications, Security & Specialist Systems",
   "section": "Electrical Services",
   "finding": "System failed (CCTV, access control, intercom)",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/communications-security-and-specialist-systems#f-system-failed-cctv-access-control-intercom"
  },
  {
   "grading": "failure",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "finding": "Only accessible route unavailable (lift out of service, ramp blocked)",
   "impact": "3 Important",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/disabled-access#f-only-accessible-route-unavailable-lift-out-of-se"
  },
  {
   "grading": "failure",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Leveller or hoist inoperable at a dock still in use",
   "impact": "4 Essential",
   "timing": "Repair now or take the dock out of service.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-leveller-or-hoist-inoperable-at-a-dock-still-in"
  },
  {
   "grading": "failure",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Leveller rating below the weight of the current forklift fleet",
   "impact": "4 Essential",
   "timing": "Restrict the fleet or replace the leveller.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-leveller-rating-below-the-weight-of-the-current"
  },
  {
   "grading": "failure",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "finding": "Condensation damaging ceilings; disconnected ducts",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#f-condensation-damaging-ceilings-disconnected-duct"
  },
  {
   "grading": "failure",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "finding": "Chargers out of service",
   "impact": "2 Planned",
   "timing": "Repair.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#f-chargers-out-of-service"
  },
  {
   "grading": "failure",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "finding": "Riser equipment failed from heat or water",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#f-riser-equipment-failed-from-heat-or-water"
  },
  {
   "grading": "failure",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "finding": "Emergency lighting failing its full-duration test across a circuit, floor or central battery",
   "impact": "4 Essential",
   "timing": "Repair now; interim measures until done.",
   "url": "https://moyneross.com/technical/emergency-lighting#f-emergency-lighting-failing-its-full-duration-tes"
  },
  {
   "grading": "failure",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "finding": "Generator or UPS failed",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/emergency-power#f-generator-or-ups-failed"
  },
  {
   "grading": "failure",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Chain elongation at or beyond the discard limit",
   "impact": "4 Essential",
   "timing": "Replace now; the unit should not run on.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-chain-elongation-at-or-beyond-the-discard-limit"
  },
  {
   "grading": "failure",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Unit out of service, or stopping unpredictably in service",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-unit-out-of-service-or-stopping-unpredictably-in"
  },
  {
   "grading": "failure",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Truss corrosion found beneath the steps",
   "impact": "4 Essential",
   "timing": "Assess structurally; plan replacement.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-truss-corrosion-found-beneath-the-steps"
  },
  {
   "grading": "failure",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "finding": "Coating failure with concrete spalling and exposed reinforcement",
   "impact": "3 Important",
   "timing": "Concrete repair and recoat now.",
   "url": "https://moyneross.com/technical/external-coating-systems#f-coating-failure-with-concrete-spalling-and-expos"
  },
  {
   "grading": "failure",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "finding": "Gate or fence failed; site insecure",
   "impact": "2 Planned",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#f-gate-or-fence-failed-site-insecure"
  },
  {
   "grading": "failure",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "finding": "Panel failed or out of service",
   "impact": "4 Essential",
   "timing": "Restore now with interim fire watch.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#f-panel-failed-or-out-of-service"
  },
  {
   "grading": "failure",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "finding": "Pump failed or out of service",
   "impact": "4 Essential",
   "timing": "Repair now with impairment management.",
   "url": "https://moyneross.com/technical/fire-pumping-systems#f-pump-failed-or-out-of-service"
  },
  {
   "grading": "failure",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "finding": "Appliance failed",
   "impact": "4 Essential",
   "timing": "Repair or replace.",
   "url": "https://moyneross.com/technical/fireplaces#f-appliance-failed"
  },
  {
   "grading": "failure",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "finding": "Floor failed (lifting, tenting)",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/flooring#f-floor-failed-lifting-tenting"
  },
  {
   "grading": "failure",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "finding": "Progressive movement with cracks of 5 to 15 mm or more",
   "impact": "4 Essential",
   "timing": "Stabilise now: fix the cause and underpin where needed.",
   "url": "https://moyneross.com/technical/foundations#f-progressive-movement-with-cracks-of-5-to-15-mm-o"
  },
  {
   "grading": "failure",
   "page": "gas-services",
   "element": "Gas Services",
   "section": "Hydraulic Services",
   "finding": "Supply disconnected by the network for safety",
   "impact": "4 Essential",
   "timing": "Repair and recommission now.",
   "url": "https://moyneross.com/technical/gas-services#f-supply-disconnected-by-the-network-for-safety"
  },
  {
   "grading": "failure",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "finding": "Active leaks damaging slab edges, finishes or units below; corroded anchors with displacement",
   "impact": "4 Essential",
   "timing": "Repair now; locate the leak path by water testing first.",
   "url": "https://moyneross.com/technical/glazing-systems#f-active-leaks-damaging-slab-edges-finishes-or-uni"
  },
  {
   "grading": "failure",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "finding": "Asbestos released by works",
   "impact": "4 Essential",
   "timing": "Stop work, decontaminate and clear now.",
   "url": "https://moyneross.com/technical/hazardous-materials#f-asbestos-released-by-works"
  },
  {
   "grading": "failure",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "finding": "Tower out of service; fill collapsed; fan failure",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/heat-rejection-plant#f-tower-out-of-service-fill-collapsed-fan-failure"
  },
  {
   "grading": "failure",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "finding": "Heater failed; no hot water",
   "impact": "3 Important",
   "timing": "Replace now.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#f-heater-failed-no-hot-water"
  },
  {
   "grading": "failure",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "finding": "Main burst or leaking under test; riser or hydrant system out of service",
   "impact": "4 Essential",
   "timing": "Repair now; notify the brigade and manage the impairment.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#f-main-burst-or-leaking-under-test-riser-or-hydran"
  },
  {
   "grading": "failure",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Saturated insulation; active condensation decaying the structure",
   "impact": "2 Planned",
   "timing": "Remove wet insulation and fix the cause now.",
   "url": "https://moyneross.com/technical/insulation#f-saturated-insulation-active-condensation-decayin"
  },
  {
   "grading": "failure",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "finding": "Integration failure stopping plant or access",
   "impact": "3 Important",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/integrated-building-systems#f-integration-failure-stopping-plant-or-access"
  },
  {
   "grading": "failure",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "finding": "Doors failed or security breached",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#f-doors-failed-or-security-breached"
  },
  {
   "grading": "failure",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "finding": "Stair unusable through damage or leaks",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/internal-stairwells#f-stair-unusable-through-damage-or-leaks"
  },
  {
   "grading": "failure",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "finding": "Ceiling collapsed or water-damaged",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#f-ceiling-collapsed-or-water-damaged"
  },
  {
   "grading": "failure",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "finding": "Active leaks damaging floors or units below",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/kitchen#f-active-leaks-damaging-floors-or-units-below"
  },
  {
   "grading": "failure",
   "page": "landscaping-and-irrigation",
   "element": "Landscaping & Irrigation",
   "section": "External Elements",
   "finding": "Planter leaks damaging structure or units",
   "impact": "2 Planned",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/landscaping-and-irrigation#f-planter-leaks-damaging-structure-or-units"
  },
  {
   "grading": "failure",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "finding": "Lifts out of service from heat or flooding",
   "impact": "4 Essential",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#f-lifts-out-of-service-from-heat-or-flooding"
  },
  {
   "grading": "failure",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "finding": "Stairs, car parks or paths unlit",
   "impact": "3 Important",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/lighting#f-stairs-car-parks-or-paths-unlit"
  },
  {
   "grading": "failure",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "finding": "System failed, lights stuck on or off",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/lighting-control-system#f-system-failed-lights-stuck-on-or-off"
  },
  {
   "grading": "failure",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "finding": "System broken (continuity lost)",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/lightning-protection#f-system-broken-continuity-lost"
  },
  {
   "grading": "failure",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "finding": "Failed lintels with dropped masonry; unsupported loads after alterations",
   "impact": "4 Essential",
   "timing": "Support and repair now.",
   "url": "https://moyneross.com/technical/load-bearing-masonry#f-failed-lintels-with-dropped-masonry-unsupported"
  },
  {
   "grading": "failure",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "finding": "Dock unusable through door, leveller or flooding failure",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#f-dock-unusable-through-door-leveller-or-flooding"
  },
  {
   "grading": "failure",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "finding": "Leaks damaging finishes; lights and detectors failed at height",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#f-leaks-damaging-finishes-lights-and-detectors-fai"
  },
  {
   "grading": "failure",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "finding": "Unit failed serving a critical space",
   "impact": "3 Important",
   "timing": "Repair or replace now.",
   "url": "https://moyneross.com/technical/localised-hvac#f-unit-failed-serving-a-critical-space"
  },
  {
   "grading": "failure",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "finding": "Main board or transformer failed; building without supply",
   "impact": "4 Essential",
   "timing": "Restore now; temporary supply.",
   "url": "https://moyneross.com/technical/main-electrical-supply#f-main-board-or-transformer-failed-building-withou"
  },
  {
   "grading": "failure",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "finding": "Entry doors failed, building insecure or inaccessible",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#f-entry-doors-failed-building-insecure-or-inaccess"
  },
  {
   "grading": "failure",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "finding": "Access equipment damaged or unusable",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/maintenance-access-areas#f-access-equipment-damaged-or-unusable"
  },
  {
   "grading": "failure",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "finding": "Displaced lintel with dropped brickwork; cracks 15 mm and wider; active water entry damaging the structure behind",
   "impact": "4 Essential",
   "timing": "Repair now; propping where load-bearing.",
   "url": "https://moyneross.com/technical/masonry-brickwork#f-displaced-lintel-with-dropped-brickwork-cracks-1"
  },
  {
   "grading": "failure",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "finding": "Injury-causing defects",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#f-injury-causing-defects"
  },
  {
   "grading": "failure",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "finding": "Partitions damaged or unusable",
   "impact": "3 Important",
   "timing": "Repair.",
   "url": "https://moyneross.com/technical/partitioning-systems#f-partitions-damaged-or-unusable"
  },
  {
   "grading": "failure",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Lift out of service, or entrapments recurring",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-lift-out-of-service-or-entrapments-recurring"
  },
  {
   "grading": "failure",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "The only lift in a building with occupants who depend on it out of service",
   "impact": "4 Essential",
   "timing": "Repair now and make interim arrangements for residents.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-the-only-lift-in-a-building-with-occupants-who-d"
  },
  {
   "grading": "failure",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "finding": "Fire-resisting construction or doors damaged by fire, water or impact and no longer intact",
   "impact": "4 Essential",
   "timing": "Repair now; interim measures until done.",
   "url": "https://moyneross.com/technical/passive-fire-protection#f-fire-resisting-construction-or-doors-damaged-by"
  },
  {
   "grading": "failure",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "finding": "Pavement failure in operational truck areas",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/pavements-and-hardstand#f-pavement-failure-in-operational-truck-areas"
  },
  {
   "grading": "failure",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "finding": "Plant room flooded or overheated causing outages",
   "impact": "3 Important",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/plant-rooms#f-plant-room-flooded-or-overheated-causing-outages"
  },
  {
   "grading": "failure",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Leaks at the roof junction or copings",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-leaks-at-the-roof-junction-or-copings"
  },
  {
   "grading": "failure",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "finding": "Extinguisher failed to discharge in use, or cylinder corroded or damaged",
   "impact": "4 Essential",
   "timing": "Remove from service and replace now.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#f-extinguisher-failed-to-discharge-in-use-or-cylin"
  },
  {
   "grading": "failure",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "finding": "Circuits or boards failed",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/power-distribution#f-circuits-or-boards-failed"
  },
  {
   "grading": "failure",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "finding": "Leaks damaging floors below; amenities closed",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/public-amenities#f-leaks-damaging-floors-below-amenities-closed"
  },
  {
   "grading": "failure",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "finding": "Pumps failed; flooding or no water to upper floors",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/pumping-systems#f-pumps-failed-flooding-or-no-water-to-upper-floor"
  },
  {
   "grading": "failure",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Perforated box gutters or failed internal joints leaking into the building",
   "impact": "3 Important",
   "timing": "Repair now; replace the failed runs.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-perforated-box-gutters-or-failed-internal-joints"
  },
  {
   "grading": "failure",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Siphonic system failing in storms, with water inside",
   "impact": "3 Important",
   "timing": "Restore outlets now; check the design.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-siphonic-system-failing-in-storms-with-water-ins"
  },
  {
   "grading": "failure",
   "page": "recreational-facilities",
   "element": "Recreational Facilities",
   "section": "External Elements",
   "finding": "Facility out of use",
   "impact": "4 Essential",
   "timing": "Repair.",
   "url": "https://moyneross.com/technical/recreational-facilities#f-facility-out-of-use"
  },
  {
   "grading": "failure",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "finding": "Leaks damaging neighbours",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#f-leaks-damaging-neighbours"
  },
  {
   "grading": "failure",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "finding": "Leaks damaging adjacent tenancies or structure",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/retail-tenancies#f-leaks-damaging-adjacent-tenancies-or-structure"
  },
  {
   "grading": "failure",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Active leak wetting structure, insulation, electrics or occupied space",
   "impact": "3 Important",
   "timing": "Repair now; find the junction before condemning the sheet.",
   "url": "https://moyneross.com/technical/roof-coverings#f-junction-leak"
  },
  {
   "grading": "failure",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Perforated sheets",
   "impact": "3 Important",
   "timing": "Repair now; replace the failed bays.",
   "url": "https://moyneross.com/technical/roof-coverings#f-perforated-sheets"
  },
  {
   "grading": "failure",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Slates or tiles already falling, slippage spreading",
   "impact": "3 Important",
   "timing": "Repair now; plan re-slating or re-battening.",
   "url": "https://moyneross.com/technical/roof-coverings#f-spreading-slippage"
  },
  {
   "grading": "failure",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Shingles creased, torn or missing after wind",
   "impact": "3 Important",
   "timing": "Repair now: replace the damaged shingles and check that the shingles around them are sealed.",
   "url": "https://moyneross.com/technical/roof-coverings#f-shingle-wind-damage"
  },
  {
   "grading": "failure",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Anchors or lines uncertified, failed inspection, or energy absorbers deployed",
   "impact": "4 Essential",
   "timing": "Withdraw from use; repair and recertify.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-anchors-or-lines-uncertified-failed-inspection-o"
  },
  {
   "grading": "failure",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Rafter spread pushing walls out; members decayed or corroded through at bearings",
   "impact": "4 Essential",
   "timing": "Repair or strengthen now.",
   "url": "https://moyneross.com/technical/roof-structure#f-rafter-spread-pushing-walls-out-members-decayed"
  },
  {
   "grading": "failure",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Plant, solar or tanks overloading members, with visible deflection",
   "impact": "4 Essential",
   "timing": "Relieve the load; strengthen or relocate.",
   "url": "https://moyneross.com/technical/roof-structure#f-plant-solar-or-tanks-overloading-members-with-vi"
  },
  {
   "grading": "failure",
   "page": "sanitary-and-drainage-systems",
   "element": "Sanitary & Drainage Systems",
   "section": "Hydraulic Services",
   "finding": "Collapsed drains; blocked stacks; wet area leaks damaging structure",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/sanitary-and-drainage-systems#f-collapsed-drains-blocked-stacks-wet-area-leaks-d"
  },
  {
   "grading": "failure",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "finding": "Failed joints with water entering and damaging finishes, fixings or framing",
   "impact": "3 Important",
   "timing": "Repair now; locate leaks by water testing.",
   "url": "https://moyneross.com/technical/sealants-and-joints#f-failed-joints-with-water-entering-and-damaging-f"
  },
  {
   "grading": "failure",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "finding": "Leaks or service damage",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/service-corridors#f-leaks-or-service-damage"
  },
  {
   "grading": "failure",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Leaks damaging interiors",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-leaks-damaging-interiors"
  },
  {
   "grading": "failure",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Smoke vents that do not open, or have been disabled",
   "impact": "4 Essential",
   "timing": "Restore now; the building's fire strategy relies on them.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-smoke-vents-that-do-not-open-or-have-been-disabl"
  },
  {
   "grading": "failure",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "finding": "Slab broken up in operational aisles",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/slab-on-ground#f-slab-broken-up-in-operational-aisles"
  },
  {
   "grading": "failure",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "finding": "Fans or dampers failed",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/smoke-management-systems#f-fans-or-dampers-failed"
  },
  {
   "grading": "failure",
   "page": "solar-photovoltaic-systems",
   "element": "Solar Photovoltaic (PV) Systems",
   "section": "Electrical Services",
   "finding": "Inverter failed; no generation",
   "impact": "3 Important",
   "timing": "Repair or replace now.",
   "url": "https://moyneross.com/technical/solar-photovoltaic-systems#f-inverter-failed-no-generation"
  },
  {
   "grading": "failure",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "finding": "Critical service failed (exhaust, gases, nurse call)",
   "impact": "3 Important",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#f-critical-service-failed-exhaust-gases-nurse-call"
  },
  {
   "grading": "failure",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "finding": "Feature failed; moisture damaging the building",
   "impact": "4 Essential",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#f-feature-failed-moisture-damaging-the-building"
  },
  {
   "grading": "failure",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "finding": "Pool or treatment plant failed; podium pool leaking into structure",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/specialist-hydraulics#f-pool-or-treatment-plant-failed-podium-pool-leaki"
  },
  {
   "grading": "failure",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "Room integrity failed",
   "impact": "4 Essential",
   "timing": "Seal now.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-room-integrity-failed"
  },
  {
   "grading": "failure",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "finding": "Flood or leak damaging stored contents",
   "impact": "3 Important",
   "timing": "Stop the water now.",
   "url": "https://moyneross.com/technical/storage-and-archive-areas#f-flood-or-leak-damaging-stored-contents"
  },
  {
   "grading": "failure",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "finding": "Collapsed pipes; blocked system causing flooding",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/stormwater-drainage#f-collapsed-pipes-blocked-system-causing-flooding"
  },
  {
   "grading": "failure",
   "page": "structural-core",
   "element": "Structural Core",
   "section": "Superstructure",
   "finding": "Shear distress cracking",
   "impact": "4 Essential",
   "timing": "Repair and strengthen now.",
   "url": "https://moyneross.com/technical/structural-core#f-shear-distress-cracking"
  },
  {
   "grading": "failure",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "finding": "Corrosion with loss of section in members; cut tendons",
   "impact": "4 Essential",
   "timing": "Repair or strengthen now.",
   "url": "https://moyneross.com/technical/structural-frame#f-corrosion-with-loss-of-section-in-members-cut-te"
  },
  {
   "grading": "failure",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "finding": "Active termites; dry rot; failed stumps",
   "impact": "4 Essential",
   "timing": "Treat and repair now.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#f-active-termites-dry-rot-failed-stumps"
  },
  {
   "grading": "failure",
   "page": "sub-metering",
   "element": "Sub-metering",
   "section": "Environmental",
   "finding": "Metering system failed; no data for billing",
   "impact": "2 Planned",
   "timing": "Restore now.",
   "url": "https://moyneross.com/technical/sub-metering#f-metering-system-failed-no-data-for-billing"
  },
  {
   "grading": "failure",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "finding": "Widespread leaks damaging fit-outs",
   "impact": "3 Important",
   "timing": "Clear drains and repair now.",
   "url": "https://moyneross.com/technical/terminal-units#f-widespread-leaks-damaging-fit-outs"
  },
  {
   "grading": "failure",
   "page": "trade-waste-systems",
   "element": "Trade Waste Systems",
   "section": "Hydraulic Services",
   "finding": "Arrestor overflowing; sewer blocked",
   "impact": "3 Important",
   "timing": "Pump out and clear now.",
   "url": "https://moyneross.com/technical/trade-waste-systems#f-arrestor-overflowing-sewer-blocked"
  },
  {
   "grading": "failure",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "finding": "Significant deflection or cracking from overload or damage",
   "impact": "4 Essential",
   "timing": "Strengthen or repair now.",
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#f-significant-deflection-or-cracking-from-overload"
  },
  {
   "grading": "failure",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "finding": "Fans failed; exhaust disconnected",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/ventilation-systems#f-fans-failed-exhaust-disconnected"
  },
  {
   "grading": "failure",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Leaks damaging the structure or units below; spalling exposing reinforcement",
   "impact": "4 Essential",
   "timing": "Repair now; extent from investigation.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-leaks-damaging-the-structure-or-units-below-spal"
  },
  {
   "grading": "failure",
   "page": "water-conservation",
   "element": "Water Conservation",
   "section": "Environmental",
   "finding": "Major leak",
   "impact": "2 Planned",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/water-conservation#f-major-leak"
  },
  {
   "grading": "failure",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "finding": "Burst main or major leak; no water to the building",
   "impact": "3 Important",
   "timing": "Repair now.",
   "url": "https://moyneross.com/technical/water-supply#f-burst-main-or-major-leak-no-water-to-the-buildin"
  },
  {
   "grading": "failure",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Active leaks damaging structure, services or occupied space",
   "impact": "3 Important",
   "timing": "Repair now; establish whether the insulation is wet.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-active-leaks-damaging-structure-services-or-occu"
  },
  {
   "grading": "failure",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Wet insulation over a wide area beneath a warm roof",
   "impact": "3 Important",
   "timing": "Plan strip and replace; repairs alone will not stop the leaks.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-wet-insulation-over-a-wide-area-beneath-a-warm-r"
  },
  {
   "grading": "condition",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Worn drives, failing batteries, corrosion at an external unit",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-worn-drives-failing-batteries-corrosion-at-an-ex"
  },
  {
   "grading": "condition",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "No maintenance contract in place",
   "impact": "3 Important",
   "timing": "Put one in place now.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-no-maintenance-contract-in-place"
  },
  {
   "grading": "condition",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Unit works but users cannot operate it independently",
   "impact": "4 Essential",
   "timing": "Fix controls, keys, call points and signage.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-unit-works-but-users-cannot-operate-it-independe"
  },
  {
   "grading": "condition",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "finding": "Outside air below code minimum; failed dampers; corroded drain pans; fouled coils",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/air-handling-units#f-outside-air-below-code-minimum-failed-dampers-co"
  },
  {
   "grading": "condition",
   "page": "ancillary-structures",
   "element": "Ancillary Structures",
   "section": "External Elements",
   "finding": "Decay or corrosion starting; worn shade fabric",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/ancillary-structures#f-decay-or-corrosion-starting-worn-shade-fabric"
  },
  {
   "grading": "condition",
   "page": "architectural-and-decorative-features",
   "element": "Architectural & Decorative Features",
   "section": "Façades",
   "finding": "Active cramp or anchor corrosion cracking units, without displacement; widespread terracotta spalling",
   "impact": "2 Planned",
   "timing": "Programme re-anchoring and repair in the near term.",
   "url": "https://moyneross.com/technical/architectural-and-decorative-features#f-active-cramp-or-anchor-corrosion-cracking-units"
  },
  {
   "grading": "condition",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "finding": "Corrosion, MIC, head defects, coverage gaps after fit-outs",
   "impact": "4 Essential",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#f-corrosion-mic-head-defects-coverage-gaps-after-f"
  },
  {
   "grading": "condition",
   "page": "basement-cellars-and-retaining-walls",
   "element": "Basement, Cellars & Retaining Walls",
   "section": "Substructure",
   "finding": "Seepage, efflorescence, blocked drainage, early rotation",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/basement-cellars-and-retaining-walls#f-seepage-efflorescence-blocked-drainage-early-rot"
  },
  {
   "grading": "condition",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "finding": "Cracked grout, failed sealant, weak exhaust, mould",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#f-cracked-grout-failed-sealant-weak-exhaust-mould"
  },
  {
   "grading": "condition",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "finding": "Corrosion, wear and leaks at fixings without a failed item",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/building-maintenance-units#f-corrosion-wear-and-leaks-at-fixings-without-a-fa"
  },
  {
   "grading": "condition",
   "page": "building-management-and-control-system",
   "element": "Building Management & Control System (BMCS)",
   "section": "Mechanical Services",
   "finding": "Unsupported controllers and software; drifted sensors; overrides",
   "impact": "3 Important",
   "timing": "Upgrade and recommission in the near term.",
   "url": "https://moyneross.com/technical/building-management-and-control-system#f-unsupported-controllers-and-software-drifted-sen"
  },
  {
   "grading": "condition",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "finding": "Rod and frame corrosion without movement; cracked masonry around anchorages without displacement",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/canopies-and-awnings#f-rod-and-frame-corrosion-without-movement-cracked"
  },
  {
   "grading": "condition",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "finding": "Rising approaches, recurring leaks, worn pumps, unsupported drives or controls",
   "impact": "3 Important",
   "timing": "Repair, retube or upgrade in the near term.",
   "url": "https://moyneross.com/technical/central-cooling-plant#f-rising-approaches-recurring-leaks-worn-pumps-uns"
  },
  {
   "grading": "condition",
   "page": "central-heating-plant",
   "element": "Central Heating Plant",
   "section": "Mechanical Services",
   "finding": "Sludge, corrosion, failed expansion vessel, poor combustion",
   "impact": "3 Important",
   "timing": "Repair and treat in the near term.",
   "url": "https://moyneross.com/technical/central-heating-plant#f-sludge-corrosion-failed-expansion-vessel-poor-co"
  },
  {
   "grading": "condition",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Cracked flaunching; eroded pointing; lifted flashings without leaks",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-cracked-flaunching-eroded-pointing-lifted-flashi"
  },
  {
   "grading": "condition",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Spalling precast from reinforcement corrosion; fixing corrosion without displacement; leaks at windows",
   "impact": "3 Important",
   "timing": "Programme repair in the near term; extent from investigation.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-spalling-precast-from-reinforcement-corrosion-fi"
  },
  {
   "grading": "condition",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "finding": "Floor, lining and drainage defects",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/commercial-kitchens#f-floor-lining-and-drainage-defects"
  },
  {
   "grading": "condition",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "finding": "Comfort complaints; worn finishes in common areas; fit-out residue affecting services",
   "impact": "2 Planned",
   "timing": "Repair or rebalance in the near term.",
   "url": "https://moyneross.com/technical/commercial-office-areas#f-comfort-complaints-worn-finishes-in-common-areas"
  },
  {
   "grading": "condition",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "finding": "Worn finishes; wall damage; odours",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/common-circulation-areas#f-worn-finishes-wall-damage-odours"
  },
  {
   "grading": "condition",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "finding": "Worn finishes; security weaknesses",
   "impact": "2 Planned",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/common-internal-areas#f-worn-finishes-security-weaknesses"
  },
  {
   "grading": "condition",
   "page": "communications-security-and-specialist-systems",
   "element": "Communications, Security & Specialist Systems",
   "section": "Electrical Services",
   "finding": "Unsupported systems; cyber exposure; coverage gaps",
   "impact": "3 Important",
   "timing": "Upgrade in the near term.",
   "url": "https://moyneross.com/technical/communications-security-and-specialist-systems#f-unsupported-systems-cyber-exposure-coverage-gaps"
  },
  {
   "grading": "condition",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "finding": "Heavy doors, faded contrast, missing signage, accessible toilets misused",
   "impact": "3 Important",
   "timing": "Fix in the near term.",
   "url": "https://moyneross.com/technical/disabled-access#f-heavy-doors-faded-contrast-missing-signage-acces"
  },
  {
   "grading": "condition",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Hydraulic leaks, deck drift, worn bumpers, broken pit edges, failed dock seals",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-hydraulic-leaks-deck-drift-worn-bumpers-broken-p"
  },
  {
   "grading": "condition",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "No maintenance regime for the goods hoists; no free-fall testing record",
   "impact": "3 Important",
   "timing": "Put a regime in place now.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-no-maintenance-regime-for-the-goods-hoists-no-fr"
  },
  {
   "grading": "condition",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "finding": "Dirty ductwork, poor balance, torn insulation",
   "impact": "3 Important",
   "timing": "Clean, rebalance and repair in the near term.",
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#f-dirty-ductwork-poor-balance-torn-insulation"
  },
  {
   "grading": "condition",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "finding": "Unmetered charging; poor load management; ageing chargers",
   "impact": "2 Planned",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#f-unmetered-charging-poor-load-management-ageing-c"
  },
  {
   "grading": "condition",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "finding": "Congestion; overheating; poor labelling",
   "impact": "3 Important",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#f-congestion-overheating-poor-labelling"
  },
  {
   "grading": "condition",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "finding": "Batteries failing duration tests across the installation",
   "impact": "4 Essential",
   "timing": "Replace batteries or fittings in the near term.",
   "url": "https://moyneross.com/technical/emergency-lighting#f-batteries-failing-duration-tests-across-the-inst"
  },
  {
   "grading": "condition",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "finding": "Batteries at end of life; fuel contaminated; wet stacking; capacity tight",
   "impact": "4 Essential",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/emergency-power#f-batteries-at-end-of-life-fuel-contaminated-wet-s"
  },
  {
   "grading": "condition",
   "page": "energy-efficiency-upgrades",
   "element": "Energy Efficiency Upgrades",
   "section": "Environmental",
   "finding": "Upgrades underperforming; savings drifting",
   "impact": "2 Planned",
   "timing": "Recommission in the near term.",
   "url": "https://moyneross.com/technical/energy-efficiency-upgrades#f-upgrades-underperforming-savings-drifting"
  },
  {
   "grading": "condition",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Chain and roller wear short of the limit; handrail wear; noisy drives; water in the pit",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-chain-and-roller-wear-short-of-the-limit-handrai"
  },
  {
   "grading": "condition",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Maintenance delivered below the contracted scope",
   "impact": "3 Important",
   "timing": "Enforce or re-tender now.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-maintenance-delivered-below-the-contracted-scope"
  },
  {
   "grading": "condition",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "finding": "Widespread peeling, blistering or render debonding without loss; coating failure on steel with spreading rust",
   "impact": "3 Important",
   "timing": "Repair and recoat in the near term.",
   "url": "https://moyneross.com/technical/external-coating-systems#f-widespread-peeling-blistering-or-render-debondin"
  },
  {
   "grading": "condition",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "finding": "Decay, corrosion, worn operators, faded signs",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#f-decay-corrosion-worn-operators-faded-signs"
  },
  {
   "grading": "condition",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "finding": "Contaminated or aged detectors; repeated unwanted alarms; coverage gaps; matrix out of date",
   "impact": "4 Essential",
   "timing": "Repair and recommission in the near term.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#f-contaminated-or-aged-detectors-repeated-unwanted"
  },
  {
   "grading": "condition",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "finding": "Performance decline; jockey cycling; battery or fuel issues; tank deterioration",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/fire-pumping-systems#f-performance-decline-jockey-cycling-battery-or-fu"
  },
  {
   "grading": "condition",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "finding": "Worn seals and glass",
   "impact": "4 Essential",
   "timing": "Repair.",
   "url": "https://moyneross.com/technical/fireplaces#f-worn-seals-and-glass"
  },
  {
   "grading": "condition",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "finding": "Wear; minor cupping; stains",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/flooring#f-wear-minor-cupping-stains"
  },
  {
   "grading": "condition",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "finding": "Seasonal movement causing repeated cracking; decaying stumps",
   "impact": "3 Important",
   "timing": "Address causes and repair in the near term.",
   "url": "https://moyneross.com/technical/foundations#f-seasonal-movement-causing-repeated-cracking-deca"
  },
  {
   "grading": "condition",
   "page": "gas-services",
   "element": "Gas Services",
   "section": "Hydraulic Services",
   "finding": "Corrosion; unprotected pipes; redundant pipework",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/gas-services#f-corrosion-unprotected-pipes-redundant-pipework"
  },
  {
   "grading": "condition",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "finding": "Widespread gasket shrinkage, failed perimeter seals, IGU failure across an elevation, hardware failing",
   "impact": "2 Planned",
   "timing": "Programme repair or replacement in the near term.",
   "url": "https://moyneross.com/technical/glazing-systems#f-widespread-gasket-shrinkage-failed-perimeter-sea"
  },
  {
   "grading": "condition",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "finding": "Bonded asbestos weathering; lead paint flaking",
   "impact": "4 Essential",
   "timing": "Manage or remove in the near term.",
   "url": "https://moyneross.com/technical/hazardous-materials#f-bonded-asbestos-weathering-lead-paint-flaking"
  },
  {
   "grading": "condition",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "finding": "Corrosion, scale, worn mechanicals",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/heat-rejection-plant#f-corrosion-scale-worn-mechanicals"
  },
  {
   "grading": "condition",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "finding": "Loop below temperature; scale; corroding tanks",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#f-loop-below-temperature-scale-corroding-tanks"
  },
  {
   "grading": "condition",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "finding": "Leaks; seized valves; missing caps; aged hoses",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#f-leaks-seized-valves-missing-caps-aged-hoses"
  },
  {
   "grading": "condition",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Mould growth in the roof space or on ceilings from condensation",
   "impact": "2 Planned",
   "timing": "Correct ventilation and vapour control in the near term.",
   "url": "https://moyneross.com/technical/insulation#f-mould-growth-in-the-roof-space-or-on-ceilings-fr"
  },
  {
   "grading": "condition",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Gaps and compression across large areas; condensation without damage yet",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/insulation#f-gaps-and-compression-across-large-areas-condensa"
  },
  {
   "grading": "condition",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Vermin-infested insulation",
   "impact": "2 Planned",
   "timing": "Remove, clean and replace after pest control.",
   "url": "https://moyneross.com/technical/insulation#f-vermin-infested-insulation"
  },
  {
   "grading": "condition",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "finding": "Cyber exposure; poor documentation",
   "impact": "3 Important",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/integrated-building-systems#f-cyber-exposure-poor-documentation"
  },
  {
   "grading": "condition",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "finding": "Worn hardware, binding doors, heavy doors on accessible routes",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#f-worn-hardware-binding-doors-heavy-doors-on-acces"
  },
  {
   "grading": "condition",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "finding": "Worn nosings; missing handrails; dark landings",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/internal-stairwells#f-worn-nosings-missing-handrails-dark-landings"
  },
  {
   "grading": "condition",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "finding": "Cracking, mould, stained tiles, worn paint",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#f-cracking-mould-stained-tiles-worn-paint"
  },
  {
   "grading": "condition",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "finding": "Swollen cabinetry; weak extraction; worn appliances",
   "impact": "2 Planned",
   "timing": "Repair or replace in the near term.",
   "url": "https://moyneross.com/technical/kitchen#f-swollen-cabinetry-weak-extraction-worn-appliance"
  },
  {
   "grading": "condition",
   "page": "landscaping-and-irrigation",
   "element": "Landscaping & Irrigation",
   "section": "External Elements",
   "finding": "Roots affecting drains and paving; bridged damp-proof courses; irrigation overspray",
   "impact": "2 Planned",
   "timing": "Address in the near term.",
   "url": "https://moyneross.com/technical/landscaping-and-irrigation#f-roots-affecting-drains-and-paving-bridged-damp-p"
  },
  {
   "grading": "condition",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "finding": "Worn interiors; hot cars; accessibility gaps",
   "impact": "4 Essential",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#f-worn-interiors-hot-cars-accessibility-gaps"
  },
  {
   "grading": "condition",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "finding": "Widespread failures; levels below standard",
   "impact": "3 Important",
   "timing": "Repair and relamp in the near term.",
   "url": "https://moyneross.com/technical/lighting#f-widespread-failures-levels-below-standard"
  },
  {
   "grading": "condition",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "finding": "Overrides, drift and poor commissioning",
   "impact": "3 Important",
   "timing": "Recommission in the near term.",
   "url": "https://moyneross.com/technical/lighting-control-system#f-overrides-drift-and-poor-commissioning"
  },
  {
   "grading": "condition",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "finding": "High earth resistance; corrosion; unbonded plant",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/lightning-protection#f-high-earth-resistance-corrosion-unbonded-plant"
  },
  {
   "grading": "condition",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "finding": "Early bowing; cracked arches; decaying lintels",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/load-bearing-masonry#f-early-bowing-cracked-arches-decaying-lintels"
  },
  {
   "grading": "condition",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "finding": "Impact damage; slab joints; waste hygiene",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#f-impact-damage-slab-joints-waste-hygiene"
  },
  {
   "grading": "condition",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "finding": "Comfort and acoustic problems; worn finishes",
   "impact": "2 Planned",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#f-comfort-and-acoustic-problems-worn-finishes"
  },
  {
   "grading": "condition",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "finding": "Coil corrosion, leaks, drain faults",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/localised-hvac#f-coil-corrosion-leaks-drain-faults"
  },
  {
   "grading": "condition",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "finding": "Thermographic hot spots; breakers failing tests; unsupported devices; partial discharge",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/main-electrical-supply#f-thermographic-hot-spots-breakers-failing-tests-u"
  },
  {
   "grading": "condition",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "finding": "Worn matting and floors; draughts; outdated directories",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#f-worn-matting-and-floors-draughts-outdated-direct"
  },
  {
   "grading": "condition",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "finding": "Corrosion; missing walkways; poor lighting",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/maintenance-access-areas#f-corrosion-missing-walkways-poor-lighting"
  },
  {
   "grading": "condition",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "finding": "Tie corrosion cracking; lintel corrosion cracking over openings; floor-line bowing on a framed building; cracks 5 to 15 mm; persistent penetrating damp",
   "impact": "2 Planned",
   "timing": "Programme repair in the near term, ahead of the next façade inspection cycle where one applies.",
   "url": "https://moyneross.com/technical/masonry-brickwork#f-tie-corrosion-cracking-lintel-corrosion-cracking"
  },
  {
   "grading": "condition",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "finding": "Worn stairs, faded signs, ageing treatments",
   "impact": "4 Essential",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#f-worn-stairs-faded-signs-ageing-treatments"
  },
  {
   "grading": "condition",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "finding": "Acoustic leakage; cracking; damage",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/partitioning-systems#f-acoustic-leakage-cracking-damage"
  },
  {
   "grading": "condition",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Rising breakdowns, worn doors, rope wear approaching discard criteria, hydraulic leaks",
   "impact": "3 Important",
   "timing": "Repair or modernise in the near term.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-rising-breakdowns-worn-doors-rope-wear-approachi"
  },
  {
   "grading": "condition",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Maintenance delivered below the contracted scope",
   "impact": "3 Important",
   "timing": "Enforce or re-tender the contract now.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-maintenance-delivered-below-the-contracted-scope"
  },
  {
   "grading": "condition",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "finding": "Widespread penetration breaches; walls not to slab; damaged structural protection",
   "impact": "4 Essential",
   "timing": "Remediation programme in the near term.",
   "url": "https://moyneross.com/technical/passive-fire-protection#f-widespread-penetration-breaches-walls-not-to-sla"
  },
  {
   "grading": "condition",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "finding": "Cracking, ruts and ponding without failure",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/pavements-and-hardstand#f-cracking-ruts-and-ponding-without-failure"
  },
  {
   "grading": "condition",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "finding": "Poor housekeeping; noise; worn floors and coatings",
   "impact": "3 Important",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/plant-rooms#f-poor-housekeeping-noise-worn-floors-and-coatings"
  },
  {
   "grading": "condition",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Open coping joints; cracked masonry without lean; corroded screen bases",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-open-coping-joints-cracked-masonry-without-lean"
  },
  {
   "grading": "condition",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Parapet too low to serve as edge protection where people work on the roof",
   "impact": "2 Planned",
   "timing": "Add guardrails before further roof access.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-parapet-too-low-to-serve-as-edge-protection-wher"
  },
  {
   "grading": "condition",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "finding": "Missing, damaged or depressurised units",
   "impact": "3 Important",
   "timing": "Replace in the near term.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#f-missing-damaged-or-depressurised-units"
  },
  {
   "grading": "condition",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "finding": "Overheating terminations; unsupported devices; unsealed penetrations; missing schedules",
   "impact": "4 Essential",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/power-distribution#f-overheating-terminations-unsupported-devices-uns"
  },
  {
   "grading": "condition",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "finding": "Worn fixtures and finishes; odour; partition damage",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/public-amenities#f-worn-fixtures-and-finishes-odour-partition-damag"
  },
  {
   "grading": "condition",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "finding": "Worn pumps, failed pressure vessels, fouled floats",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/pumping-systems#f-worn-pumps-failed-pressure-vessels-fouled-floats"
  },
  {
   "grading": "condition",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Box gutters or parapet roofs without adequate overflows",
   "impact": "3 Important",
   "timing": "Add or enlarge overflows in the near term.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-box-gutters-or-parapet-roofs-without-adequate-ov"
  },
  {
   "grading": "condition",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Gutter soles corroding where water stands; poor falls",
   "impact": "3 Important",
   "timing": "Programme repair or replacement of the affected runs.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-gutter-soles-corroding-where-water-stands-poor-f"
  },
  {
   "grading": "condition",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Lead goods stolen; water discharging against the wall",
   "impact": "3 Important",
   "timing": "Replace the goods (often in a non-lead material) in the near term.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-lead-goods-stolen-water-discharging-against-the"
  },
  {
   "grading": "condition",
   "page": "recreational-facilities",
   "element": "Recreational Facilities",
   "section": "External Elements",
   "finding": "Worn equipment; court cracking",
   "impact": "4 Essential",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/recreational-facilities#f-worn-equipment-court-cracking"
  },
  {
   "grading": "condition",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "finding": "Mould, noise complaints, worn finishes",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#f-mould-noise-complaints-worn-finishes"
  },
  {
   "grading": "condition",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "finding": "Service provisions inadequate for current market; make-good shortfalls",
   "impact": "2 Planned",
   "timing": "Upgrade at vacancy or lease renewal.",
   "url": "https://moyneross.com/technical/retail-tenancies#f-service-provisions-inadequate-for-current-market"
  },
  {
   "grading": "condition",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Lap and edge corrosion short of perforation",
   "impact": "3 Important",
   "timing": "Programme repair or partial replacement in the near term: treat and coat where the metal is intact; replace the lower run above the gutter where it is not.",
   "url": "https://moyneross.com/technical/roof-coverings#f-lap-edge-corrosion"
  },
  {
   "grading": "condition",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Condensation corroding sheets from beneath",
   "impact": "3 Important",
   "timing": "Correct the cause (vapour control, ventilation) before renewing the covering.",
   "url": "https://moyneross.com/technical/roof-coverings#f-underside-condensation"
  },
  {
   "grading": "condition",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Fixings leaking or backing out",
   "impact": "3 Important",
   "timing": "Replace failed fixings with oversized screws and new washers.",
   "url": "https://moyneross.com/technical/roof-coverings#f-fixings-backing-out"
  },
  {
   "grading": "condition",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Loose ridge and hip cappings",
   "impact": "3 Important",
   "timing": "Rebed and repoint the ridges and hips.",
   "url": "https://moyneross.com/technical/roof-coverings#f-loose-ridges"
  },
  {
   "grading": "condition",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Isolated slipped slates",
   "impact": "3 Important",
   "timing": "Refix or replace the slipped slates; where slippage keeps spreading, plan re-slating with stainless steel or copper nails.",
   "url": "https://moyneross.com/technical/roof-coverings#f-nail-sickness"
  },
  {
   "grading": "condition",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "No rescue plan for a fall arrest system in use",
   "impact": "4 Essential",
   "timing": "Prepare the plan and equipment before the next use.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-no-rescue-plan-for-a-fall-arrest-system-in-use"
  },
  {
   "grading": "condition",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Fall arrest relied on for frequent routine access",
   "impact": "3 Important",
   "timing": "Add collective protection along the routes in the near term.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-fall-arrest-relied-on-for-frequent-routine-acces"
  },
  {
   "grading": "condition",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Corrosion without failure; loose guardrail fixings; rigging plan out of date",
   "impact": "3 Important",
   "timing": "Programme repair and update in the near term.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-corrosion-without-failure-loose-guardrail-fixing"
  },
  {
   "grading": "condition",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Cut webs, missing bracing or bridging; corrosion taking section; termite damage short of failure",
   "impact": "3 Important",
   "timing": "Programme repair in the near term.",
   "url": "https://moyneross.com/technical/roof-structure#f-cut-webs-missing-bracing-or-bridging-corrosion-t"
  },
  {
   "grading": "condition",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Bracing slack or removed; fly braces missing",
   "impact": "3 Important",
   "timing": "Restore before the next high-wind season.",
   "url": "https://moyneross.com/technical/roof-structure#f-bracing-slack-or-removed-fly-braces-missing"
  },
  {
   "grading": "condition",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Tie-down well below current requirements in a cyclonic or high-wind region",
   "impact": "3 Important",
   "timing": "Upgrade at the next re-roofing, sooner if exposed.",
   "url": "https://moyneross.com/technical/roof-structure#f-tie-down-well-below-current-requirements-in-a-cy"
  },
  {
   "grading": "condition",
   "page": "sanitary-and-drainage-systems",
   "element": "Sanitary & Drainage Systems",
   "section": "Hydraulic Services",
   "finding": "Root intrusion, corrosion, displaced joints",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/sanitary-and-drainage-systems#f-root-intrusion-corrosion-displaced-joints"
  },
  {
   "grading": "condition",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "finding": "Failed fire-rated joints at slab edges or through fire-separating walls",
   "impact": "2 Planned",
   "timing": "Repair with a tested system in the near term; it is a fire compliance item.",
   "url": "https://moyneross.com/technical/sealants-and-joints#f-failed-fire-rated-joints-at-slab-edges-or-throug"
  },
  {
   "grading": "condition",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "finding": "Widespread adhesive or cohesive failure with no damage yet",
   "impact": "2 Planned",
   "timing": "Programme replacement in the near term, by elevation.",
   "url": "https://moyneross.com/technical/sealants-and-joints#f-widespread-adhesive-or-cohesive-failure-with-no"
  },
  {
   "grading": "condition",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "finding": "Impact damage; hygiene; poor lighting",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/service-corridors#f-impact-damage-hygiene-poor-lighting"
  },
  {
   "grading": "condition",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Embrittled sheets; seals at end of life",
   "impact": "3 Important",
   "timing": "Replace in the near term.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-embrittled-sheets-seals-at-end-of-life"
  },
  {
   "grading": "condition",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Condensation dripping onto finishes or stock",
   "impact": "2 Planned",
   "timing": "Improve ventilation, heating or glazing in the near term.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-condensation-dripping-onto-finishes-or-stock"
  },
  {
   "grading": "condition",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "finding": "Joint deterioration; curling; moisture-driven flooring failures",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/slab-on-ground#f-joint-deterioration-curling-moisture-driven-floo"
  },
  {
   "grading": "condition",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "finding": "Equipment worn; partial interface faults",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/smoke-management-systems#f-equipment-worn-partial-interface-faults"
  },
  {
   "grading": "condition",
   "page": "solar-photovoltaic-systems",
   "element": "Solar Photovoltaic (PV) Systems",
   "section": "Electrical Services",
   "finding": "Degradation, corrosion, leaks",
   "impact": "2 Planned",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/solar-photovoltaic-systems#f-degradation-corrosion-leaks"
  },
  {
   "grading": "condition",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "finding": "Worn finishes; acoustic and ventilation shortfalls",
   "impact": "2 Planned",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#f-worn-finishes-acoustic-and-ventilation-shortfall"
  },
  {
   "grading": "condition",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "finding": "Condensation; ageing plant",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#f-condensation-ageing-plant"
  },
  {
   "grading": "condition",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "finding": "Worn finishes, ageing plant, corroded equipment",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/specialist-hydraulics#f-worn-finishes-ageing-plant-corroded-equipment"
  },
  {
   "grading": "condition",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "Panel or detection ageing",
   "impact": "3 Important",
   "timing": "Repair.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-panel-or-detection-ageing"
  },
  {
   "grading": "condition",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "finding": "Damp, pests, poor housekeeping",
   "impact": "2 Planned",
   "timing": "Improve in the near term.",
   "url": "https://moyneross.com/technical/storage-and-archive-areas#f-damp-pests-poor-housekeeping"
  },
  {
   "grading": "condition",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "finding": "Sediment build-up; roots; failing devices",
   "impact": "3 Important",
   "timing": "Clean and repair in the near term.",
   "url": "https://moyneross.com/technical/stormwater-drainage#f-sediment-build-up-roots-failing-devices"
  },
  {
   "grading": "condition",
   "page": "structural-core",
   "element": "Structural Core",
   "section": "Superstructure",
   "finding": "Corroded bracing connections; minor unengineered penetrations",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/structural-core#f-corroded-bracing-connections-minor-unengineered"
  },
  {
   "grading": "condition",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "finding": "Corrosion and spalling without significant section loss; ASR; failed car park membranes",
   "impact": "3 Important",
   "timing": "Repair programme in the near term.",
   "url": "https://moyneross.com/technical/structural-frame#f-corrosion-and-spalling-without-significant-secti"
  },
  {
   "grading": "condition",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "finding": "Blocked ventilation; damp; decay starting",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#f-blocked-ventilation-damp-decay-starting"
  },
  {
   "grading": "condition",
   "page": "sub-metering",
   "element": "Sub-metering",
   "section": "Environmental",
   "finding": "Mapping errors; ratio and polarity faults; data gaps",
   "impact": "2 Planned",
   "timing": "Correct in the near term.",
   "url": "https://moyneross.com/technical/sub-metering#f-mapping-errors-ratio-and-polarity-faults-data-ga"
  },
  {
   "grading": "condition",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "finding": "Many units with failed actuators, drifted sensors or blocked drains",
   "impact": "3 Important",
   "timing": "Programme in the near term.",
   "url": "https://moyneross.com/technical/terminal-units#f-many-units-with-failed-actuators-drifted-sensors"
  },
  {
   "grading": "condition",
   "page": "trade-waste-systems",
   "element": "Trade Waste Systems",
   "section": "Hydraulic Services",
   "finding": "Corroded baffles and tank; undersized for current use",
   "impact": "3 Important",
   "timing": "Repair or upgrade in the near term.",
   "url": "https://moyneross.com/technical/trade-waste-systems#f-corroded-baffles-and-tank-undersized-for-current"
  },
  {
   "grading": "condition",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "finding": "Decking corrosion; notched joists; creep deflection affecting finishes",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#f-decking-corrosion-notched-joists-creep-deflectio"
  },
  {
   "grading": "condition",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "finding": "Sensors drifting; fans worn; poor balance",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/ventilation-systems#f-sensors-drifting-fans-worn-poor-balance"
  },
  {
   "grading": "condition",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Heavy planters, spas or enclosures on a balcony not designed for them",
   "impact": "4 Essential",
   "timing": "Remove or assess the load before further use.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-heavy-planters-spas-or-enclosures-on-a-balcony-n"
  },
  {
   "grading": "condition",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Post-base corrosion without looseness; membrane leaks without structural damage; fastener corrosion on decks",
   "impact": "3 Important",
   "timing": "Programme repair in the near term.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-post-base-corrosion-without-looseness-membrane-l"
  },
  {
   "grading": "condition",
   "page": "water-conservation",
   "element": "Water Conservation",
   "section": "Environmental",
   "finding": "Leaks, timed urinals, poor tower control",
   "impact": "2 Planned",
   "timing": "Fix in the near term.",
   "url": "https://moyneross.com/technical/water-conservation#f-leaks-timed-urinals-poor-tower-control"
  },
  {
   "grading": "condition",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "finding": "Galvanised corrosion, recurring copper leaks, dezincification, seized valves, high pressure",
   "impact": "3 Important",
   "timing": "Repair in the near term.",
   "url": "https://moyneross.com/technical/water-supply#f-galvanised-corrosion-recurring-copper-leaks-dezi"
  },
  {
   "grading": "condition",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Seams opening, details failing, membrane brittle at upstands",
   "impact": "3 Important",
   "timing": "Programme detail repairs or recover in the near term.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-seams-opening-details-failing-membrane-brittle-a"
  },
  {
   "grading": "condition",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Membrane splits over structural or deck joints",
   "impact": "3 Important",
   "timing": "Install movement joints and repair in the near term.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-membrane-splits-over-structural-or-deck-joints"
  },
  {
   "grading": "condition",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Later penetrations sealed with mastic only",
   "impact": "3 Important",
   "timing": "Flash properly at the next roof works.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-later-penetrations-sealed-with-mastic-only"
  },
  {
   "grading": "lifecycle",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Manufacturer no longer supports the unit",
   "impact": "2 Planned",
   "timing": "Plan replacement; there is no modernisation path.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-manufacturer-no-longer-supports-the-unit"
  },
  {
   "grading": "lifecycle",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "finding": "Units at the end of their life; inefficient fans",
   "impact": "2 Planned",
   "timing": "Plan replacement or refurbishment.",
   "url": "https://moyneross.com/technical/air-handling-units#f-units-at-the-end-of-their-life-inefficient-fans"
  },
  {
   "grading": "lifecycle",
   "page": "ancillary-structures",
   "element": "Ancillary Structures",
   "section": "External Elements",
   "finding": "Structures and fabrics at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/ancillary-structures#f-structures-and-fabrics-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "architectural-and-decorative-features",
   "element": "Architectural & Decorative Features",
   "section": "Façades",
   "finding": "Weatherings and joints at age; surface erosion without loss of detail",
   "impact": "2 Planned",
   "timing": "Renewal on cycle with access for other façade work.",
   "url": "https://moyneross.com/technical/architectural-and-decorative-features#f-weatherings-and-joints-at-age-surface-erosion-wi"
  },
  {
   "grading": "lifecycle",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "finding": "Pipework or heads at end of life; sample testing due",
   "impact": "3 Important",
   "timing": "Plan replacement.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#f-pipework-or-heads-at-end-of-life-sample-testing"
  },
  {
   "grading": "lifecycle",
   "page": "basement-cellars-and-retaining-walls",
   "element": "Basement, Cellars & Retaining Walls",
   "section": "Substructure",
   "finding": "Sleeper walls and pumps at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/basement-cellars-and-retaining-walls#f-sleeper-walls-and-pumps-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "finding": "Bathroom at end of refurbishment cycle, or no membrane in an older bathroom",
   "impact": "2 Planned",
   "timing": "Plan a full strip and re-waterproof.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#f-bathroom-at-end-of-refurbishment-cycle-or-no-mem"
  },
  {
   "grading": "lifecycle",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "finding": "Controls approaching obsolescence; unit approaching end of structural life",
   "impact": "2 Planned",
   "timing": "Plan modernisation or replacement.",
   "url": "https://moyneross.com/technical/building-maintenance-units#f-controls-approaching-obsolescence-unit-approachi"
  },
  {
   "grading": "lifecycle",
   "page": "building-management-and-control-system",
   "element": "Building Management & Control System (BMCS)",
   "section": "Mechanical Services",
   "finding": "System at end of support",
   "impact": "2 Planned",
   "timing": "Plan replacement, preferably open protocol.",
   "url": "https://moyneross.com/technical/building-management-and-control-system#f-system-at-end-of-support"
  },
  {
   "grading": "lifecycle",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "finding": "Roof sheeting, gutters and linings at age",
   "impact": "2 Planned",
   "timing": "Renewal on cycle.",
   "url": "https://moyneross.com/technical/canopies-and-awnings#f-roof-sheeting-gutters-and-linings-at-age"
  },
  {
   "grading": "lifecycle",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "finding": "Chiller approaching end of life on run hours and age with no current faults",
   "impact": "2 Planned",
   "timing": "Plan replacement, sized to current load.",
   "url": "https://moyneross.com/technical/central-cooling-plant#f-chiller-approaching-end-of-life-on-run-hours-and"
  },
  {
   "grading": "lifecycle",
   "page": "central-heating-plant",
   "element": "Central Heating Plant",
   "section": "Mechanical Services",
   "finding": "Boilers at the end of their life; fuel policy affecting replacement choice",
   "impact": "2 Planned",
   "timing": "Plan replacement, including the electrification option.",
   "url": "https://moyneross.com/technical/central-heating-plant#f-boilers-at-the-end-of-their-life-fuel-policy-aff"
  },
  {
   "grading": "lifecycle",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Liners and flashings at age",
   "impact": "2 Planned",
   "timing": "Renew on cycle.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-liners-and-flashings-at-age"
  },
  {
   "grading": "lifecycle",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Coating faded and chalked; weatherboards due for repaint; sealant at age on a sound system",
   "impact": "2 Planned",
   "timing": "Renewal on cycle.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-coating-faded-and-chalked-weatherboards-due-for"
  },
  {
   "grading": "lifecycle",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "finding": "Fit-out and equipment at end of life",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/commercial-kitchens#f-fit-out-and-equipment-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "finding": "Floor at the end of its refurbishment cycle; market grade sliding",
   "impact": "2 Planned",
   "timing": "Plan a base-building refurbishment, ideally at lease expiry.",
   "url": "https://moyneross.com/technical/commercial-office-areas#f-floor-at-the-end-of-its-refurbishment-cycle-mark"
  },
  {
   "grading": "lifecycle",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "finding": "Corridors at end of refurbishment cycle",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/common-circulation-areas#f-corridors-at-end-of-refurbishment-cycle"
  },
  {
   "grading": "lifecycle",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "finding": "Lobby and corridors at end of refurbishment cycle",
   "impact": "2 Planned",
   "timing": "Refurbish from the capital works fund.",
   "url": "https://moyneross.com/technical/common-internal-areas#f-lobby-and-corridors-at-end-of-refurbishment-cycl"
  },
  {
   "grading": "lifecycle",
   "page": "communications-security-and-specialist-systems",
   "element": "Communications, Security & Specialist Systems",
   "section": "Electrical Services",
   "finding": "Systems at end of life",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/communications-security-and-specialist-systems#f-systems-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "finding": "Access features at end of life",
   "impact": "2 Planned",
   "timing": "Renew.",
   "url": "https://moyneross.com/technical/disabled-access#f-access-features-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Equipment at the end of its life, or dock levels unsuited to the current vehicle mix",
   "impact": "2 Planned",
   "timing": "Plan replacement.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-equipment-at-the-end-of-its-life-or-dock-levels"
  },
  {
   "grading": "lifecycle",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "finding": "Ductwork, insulation and flex at end of life",
   "impact": "2 Planned",
   "timing": "Replace with major plant or fit-out works.",
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#f-ductwork-insulation-and-flex-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "finding": "Chargers at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#f-chargers-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "finding": "Capacity exhausted for planned uses",
   "impact": "2 Planned",
   "timing": "Plan new capacity.",
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#f-capacity-exhausted-for-planned-uses"
  },
  {
   "grading": "lifecycle",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "finding": "Fluorescent fittings and old batteries at end of life",
   "impact": "3 Important",
   "timing": "Replace with LED, ideally with self-test.",
   "url": "https://moyneross.com/technical/emergency-lighting#f-fluorescent-fittings-and-old-batteries-at-end-of"
  },
  {
   "grading": "lifecycle",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "finding": "Generator or UPS at end of life",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/emergency-power#f-generator-or-ups-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "energy-efficiency-upgrades",
   "element": "Energy Efficiency Upgrades",
   "section": "Environmental",
   "finding": "Plant at end of life: an opportunity to upgrade",
   "impact": "2 Planned",
   "timing": "Replace with efficient, low-emission plant.",
   "url": "https://moyneross.com/technical/energy-efficiency-upgrades#f-plant-at-end-of-life-an-opportunity-to-upgrade"
  },
  {
   "grading": "lifecycle",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Unit at the end of its life, or its duty class unsuited to current traffic",
   "impact": "3 Important",
   "timing": "Plan modernisation in the truss, or replacement.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-unit-at-the-end-of-its-life-or-its-duty-class-un"
  },
  {
   "grading": "lifecycle",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "finding": "Chalking and fading; coating at the end of its cycle",
   "impact": "2 Planned",
   "timing": "Recoat on cycle.",
   "url": "https://moyneross.com/technical/external-coating-systems#f-chalking-and-fading-coating-at-the-end-of-its-cy"
  },
  {
   "grading": "lifecycle",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "finding": "Fences and operators at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#f-fences-and-operators-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "finding": "Unsupported panel; detectors at end of life",
   "impact": "3 Important",
   "timing": "Plan replacement before the next tenancy change.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#f-unsupported-panel-detectors-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "finding": "Pumps or controllers at end of life",
   "impact": "3 Important",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/fire-pumping-systems#f-pumps-or-controllers-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "finding": "Appliance at end of life",
   "impact": "2 Planned",
   "timing": "Replace or decommission.",
   "url": "https://moyneross.com/technical/fireplaces#f-appliance-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "finding": "Flooring at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/flooring#f-flooring-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "finding": "Timber stumps or piles at the end of their life",
   "impact": "2 Planned",
   "timing": "Plan restumping or replacement.",
   "url": "https://moyneross.com/technical/foundations#f-timber-stumps-or-piles-at-the-end-of-their-life"
  },
  {
   "grading": "lifecycle",
   "page": "gas-services",
   "element": "Gas Services",
   "section": "Hydraulic Services",
   "finding": "Piping at end of life; gas phase-out planned",
   "impact": "2 Planned",
   "timing": "Replace or decommission.",
   "url": "https://moyneross.com/technical/gas-services#f-piping-at-end-of-life-gas-phase-out-planned"
  },
  {
   "grading": "lifecycle",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "finding": "Seals and IGUs at age without failure; single-glazed system below current energy expectations",
   "impact": "2 Planned",
   "timing": "Plan renewal or upgrade, often combined with a façade programme.",
   "url": "https://moyneross.com/technical/glazing-systems#f-seals-and-igus-at-age-without-failure-single-gla"
  },
  {
   "grading": "lifecycle",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "finding": "Removal planned with refurbishment or replacement",
   "impact": "2 Planned",
   "timing": "Plan with the works.",
   "url": "https://moyneross.com/technical/hazardous-materials#f-removal-planned-with-refurbishment-or-replacemen"
  },
  {
   "grading": "lifecycle",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "finding": "Tower at end of life",
   "impact": "2 Planned",
   "timing": "Replace; consider dry or adiabatic alternatives.",
   "url": "https://moyneross.com/technical/heat-rejection-plant#f-tower-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "finding": "Heaters at end of life",
   "impact": "2 Planned",
   "timing": "Replace, considering electrification.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#f-heaters-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "finding": "Pipework and valves at end of life",
   "impact": "3 Important",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#f-pipework-and-valves-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Insulation below current standards, with roof works planned that will require an upgrade",
   "impact": "2 Planned",
   "timing": "Upgrade with the works.",
   "url": "https://moyneross.com/technical/insulation#f-insulation-below-current-standards-with-roof-wor"
  },
  {
   "grading": "lifecycle",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "finding": "Integration platforms unsupported",
   "impact": "2 Planned",
   "timing": "Plan replacement.",
   "url": "https://moyneross.com/technical/integrated-building-systems#f-integration-platforms-unsupported"
  },
  {
   "grading": "lifecycle",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "finding": "Hardware at end of life; obsolete keying",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#f-hardware-at-end-of-life-obsolete-keying"
  },
  {
   "grading": "lifecycle",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "finding": "Finishes at end of life",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/internal-stairwells#f-finishes-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "finding": "Finishes at end of cycle",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#f-finishes-at-end-of-cycle"
  },
  {
   "grading": "lifecycle",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "finding": "Kitchen at end of refurbishment cycle",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/kitchen#f-kitchen-at-end-of-refurbishment-cycle"
  },
  {
   "grading": "lifecycle",
   "page": "landscaping-and-irrigation",
   "element": "Landscaping & Irrigation",
   "section": "External Elements",
   "finding": "Planting, irrigation and green walls at end of life",
   "impact": "2 Planned",
   "timing": "Renew.",
   "url": "https://moyneross.com/technical/landscaping-and-irrigation#f-planting-irrigation-and-green-walls-at-end-of-li"
  },
  {
   "grading": "lifecycle",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "finding": "Interiors at end of life",
   "impact": "2 Planned",
   "timing": "Refurbish, ideally with modernisation.",
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#f-interiors-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "finding": "Fluorescent and HID lighting due for LED conversion",
   "impact": "2 Planned",
   "timing": "Plan conversion, often with controls.",
   "url": "https://moyneross.com/technical/lighting#f-fluorescent-and-hid-lighting-due-for-led-convers"
  },
  {
   "grading": "lifecycle",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "finding": "System unsupported or proprietary at end of life",
   "impact": "2 Planned",
   "timing": "Plan replacement, preferably open protocol.",
   "url": "https://moyneross.com/technical/lighting-control-system#f-system-unsupported-or-proprietary-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "finding": "System at end of life",
   "impact": "2 Planned",
   "timing": "Replace, often with re-roofing.",
   "url": "https://moyneross.com/technical/lightning-protection#f-system-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "finding": "Lintels at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/load-bearing-masonry#f-lintels-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "finding": "Doors, levellers and finishes at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#f-doors-levellers-and-finishes-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "finding": "Finishes and glazing seals at end of life",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#f-finishes-and-glazing-seals-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "finding": "Units at end of life",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/localised-hvac#f-units-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "finding": "Board at end of life; open-bus or fused boards",
   "impact": "2 Planned",
   "timing": "Plan replacement.",
   "url": "https://moyneross.com/technical/main-electrical-supply#f-board-at-end-of-life-open-bus-or-fused-boards"
  },
  {
   "grading": "lifecycle",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "finding": "Entrance at the end of its refurbishment cycle or below market",
   "impact": "2 Planned",
   "timing": "Plan refurbishment with leasing strategy.",
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#f-entrance-at-the-end-of-its-refurbishment-cycle-o"
  },
  {
   "grading": "lifecycle",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "finding": "Access equipment at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/maintenance-access-areas#f-access-equipment-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "finding": "Mortar eroded or friable over large areas; scattered spalling; damp-proof course bridged without salt damage yet; galvanised ties of the at-risk era with no cracking",
   "impact": "2 Planned",
   "timing": "Renewal on a planned cycle; combine with access for other façade work.",
   "url": "https://moyneross.com/technical/masonry-brickwork#f-mortar-eroded-or-friable-over-large-areas-scatte"
  },
  {
   "grading": "lifecycle",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "finding": "Stair finishes and fittings at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#f-stair-finishes-and-fittings-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "finding": "Partitions at end of fit-out life",
   "impact": "2 Planned",
   "timing": "Replace with fit-out.",
   "url": "https://moyneross.com/technical/partitioning-systems#f-partitions-at-end-of-fit-out-life"
  },
  {
   "grading": "lifecycle",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Controls, drives or machines at the end of their life; parts support ended",
   "impact": "3 Important",
   "timing": "Plan staged modernisation.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-controls-drives-or-machines-at-the-end-of-their"
  },
  {
   "grading": "lifecycle",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Waiting times materially worse than the building needs",
   "impact": "3 Important",
   "timing": "Traffic study, then control or capacity works.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-waiting-times-materially-worse-than-the-building"
  },
  {
   "grading": "lifecycle",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "finding": "Doors and hardware at end of life",
   "impact": "3 Important",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/passive-fire-protection#f-doors-and-hardware-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "finding": "Surface at end of life; resealing due",
   "impact": "2 Planned",
   "timing": "Reseal or resurface on cycle.",
   "url": "https://moyneross.com/technical/pavements-and-hardstand#f-surface-at-end-of-life-resealing-due"
  },
  {
   "grading": "lifecycle",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "finding": "No replacement route for major plant",
   "impact": "2 Planned",
   "timing": "Plan the route before the next replacement.",
   "url": "https://moyneross.com/technical/plant-rooms#f-no-replacement-route-for-major-plant"
  },
  {
   "grading": "lifecycle",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Copings, cappings and screens at age",
   "impact": "2 Planned",
   "timing": "Renew on cycle.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-copings-cappings-and-screens-at-age"
  },
  {
   "grading": "lifecycle",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "finding": "Units at end of life or failing pressure tests",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#f-units-at-end-of-life-or-failing-pressure-tests"
  },
  {
   "grading": "lifecycle",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "finding": "Wiring and boards at the end of their life",
   "impact": "2 Planned",
   "timing": "Plan rewiring floor by floor or with fit-outs.",
   "url": "https://moyneross.com/technical/power-distribution#f-wiring-and-boards-at-the-end-of-their-life"
  },
  {
   "grading": "lifecycle",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "finding": "Amenities at end of refurbishment cycle",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/public-amenities#f-amenities-at-end-of-refurbishment-cycle"
  },
  {
   "grading": "lifecycle",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "finding": "Pumps at end of life",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/pumping-systems#f-pumps-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Gutters and downpipes at the end of their life, no current leaks",
   "impact": "2 Planned",
   "timing": "Replace with the roof covering where possible.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-gutters-and-downpipes-at-the-end-of-their-life-n"
  },
  {
   "grading": "lifecycle",
   "page": "recreational-facilities",
   "element": "Recreational Facilities",
   "section": "External Elements",
   "finding": "Equipment and surfaces at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/recreational-facilities#f-equipment-and-surfaces-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "finding": "Kitchens, bathrooms and soft goods at end of cycle",
   "impact": "2 Planned",
   "timing": "Refurbish on cycle.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#f-kitchens-bathrooms-and-soft-goods-at-end-of-cycl"
  },
  {
   "grading": "lifecycle",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "finding": "Shopfronts and centre finishes at end of cycle",
   "impact": "2 Planned",
   "timing": "Refurbish with centre strategy.",
   "url": "https://moyneross.com/technical/retail-tenancies#f-shopfronts-and-centre-finishes-at-end-of-cycle"
  },
  {
   "grading": "lifecycle",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Covering near the end of its life, no current leaks",
   "impact": "2 Planned",
   "timing": "Plan replacement by zone, worst first.",
   "url": "https://moyneross.com/technical/roof-coverings#f-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Asbestos cement weathered to exposed fibre",
   "impact": "2 Planned",
   "timing": "Plan replacement by licensed removal; coating can extend the life of sound sheet but not of eroded sheet.",
   "url": "https://moyneross.com/technical/roof-coverings#f-asbestos-cement-weathered"
  },
  {
   "grading": "lifecycle",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Shingles curled, granules in the gutters",
   "impact": "2 Planned",
   "timing": "Plan replacement; the end is usually determined by an insurance inspection rather than a leak.",
   "url": "https://moyneross.com/technical/roof-coverings#f-shingle-ageing"
  },
  {
   "grading": "lifecycle",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "System at the end of its service life",
   "impact": "2 Planned",
   "timing": "Plan replacement, ideally with re-roofing.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-system-at-the-end-of-its-service-life"
  },
  {
   "grading": "lifecycle",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Coatings on steel portal frames and purlins at the end of their life",
   "impact": "2 Planned",
   "timing": "Plan recoating.",
   "url": "https://moyneross.com/technical/roof-structure#f-coatings-on-steel-portal-frames-and-purlins-at-t"
  },
  {
   "grading": "lifecycle",
   "page": "sanitary-and-drainage-systems",
   "element": "Sanitary & Drainage Systems",
   "section": "Hydraulic Services",
   "finding": "Cast iron and clay at end of life; pitch fibre",
   "impact": "2 Planned",
   "timing": "Plan replacement or relining.",
   "url": "https://moyneross.com/technical/sanitary-and-drainage-systems#f-cast-iron-and-clay-at-end-of-life-pitch-fibre"
  },
  {
   "grading": "lifecycle",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "finding": "Original sealant past 15 years on a panel or precast façade, no programme on record",
   "impact": "2 Planned",
   "timing": "Full programme due; test a sample to confirm timing.",
   "url": "https://moyneross.com/technical/sealants-and-joints#f-original-sealant-past-15-years-on-a-panel-or-pre"
  },
  {
   "grading": "lifecycle",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "finding": "Finishes and protection at end of life",
   "impact": "2 Planned",
   "timing": "Renew.",
   "url": "https://moyneross.com/technical/service-corridors#f-finishes-and-protection-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Roof lights at age",
   "impact": "2 Planned",
   "timing": "Replace on cycle, usually with the roof covering.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-roof-lights-at-age"
  },
  {
   "grading": "lifecycle",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "finding": "Joint sealants and surface treatments at end of life",
   "impact": "2 Planned",
   "timing": "Renew on cycle.",
   "url": "https://moyneross.com/technical/slab-on-ground#f-joint-sealants-and-surface-treatments-at-end-of"
  },
  {
   "grading": "lifecycle",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "finding": "Equipment at end of life",
   "impact": "3 Important",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/smoke-management-systems#f-equipment-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "solar-photovoltaic-systems",
   "element": "Solar Photovoltaic (PV) Systems",
   "section": "Electrical Services",
   "finding": "Inverters at end of life; array at end of life",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/solar-photovoltaic-systems#f-inverters-at-end-of-life-array-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "finding": "Fit-out and specialist equipment at end of life",
   "impact": "2 Planned",
   "timing": "Refurbish.",
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#f-fit-out-and-specialist-equipment-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "finding": "Feature at end of life",
   "impact": "2 Planned",
   "timing": "Replace or remove.",
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#f-feature-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "finding": "Plant and finishes at end of life",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/specialist-hydraulics#f-plant-and-finishes-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "System at end of life",
   "impact": "3 Important",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-system-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "finding": "Shelving and cages at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/storage-and-archive-areas#f-shelving-and-cages-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "finding": "Treatment media and devices at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/stormwater-drainage#f-treatment-media-and-devices-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "structural-core",
   "element": "Structural Core",
   "section": "Superstructure",
   "finding": "Protective coatings on exposed bracing at end of life",
   "impact": "2 Planned",
   "timing": "Recoat on cycle.",
   "url": "https://moyneross.com/technical/structural-core#f-protective-coatings-on-exposed-bracing-at-end-of"
  },
  {
   "grading": "lifecycle",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "finding": "Protective coatings and membranes at end of life",
   "impact": "2 Planned",
   "timing": "Renew on cycle.",
   "url": "https://moyneross.com/technical/structural-frame#f-protective-coatings-and-membranes-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "finding": "Stumps and chemical barriers at end of life",
   "impact": "2 Planned",
   "timing": "Restump; renew barriers.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#f-stumps-and-chemical-barriers-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "sub-metering",
   "element": "Sub-metering",
   "section": "Environmental",
   "finding": "Meters at end of life or on retiring networks",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/sub-metering#f-meters-at-end-of-life-or-on-retiring-networks"
  },
  {
   "grading": "lifecycle",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "finding": "Units at end of life; unsupported controllers",
   "impact": "2 Planned",
   "timing": "Plan replacement, often floor by floor.",
   "url": "https://moyneross.com/technical/terminal-units#f-units-at-end-of-life-unsupported-controllers"
  },
  {
   "grading": "lifecycle",
   "page": "trade-waste-systems",
   "element": "Trade Waste Systems",
   "section": "Hydraulic Services",
   "finding": "Arrestor at end of life",
   "impact": "2 Planned",
   "timing": "Replace.",
   "url": "https://moyneross.com/technical/trade-waste-systems#f-arrestor-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "finding": "Screeds and toppings at end of life",
   "impact": "2 Planned",
   "timing": "Renew.",
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#f-screeds-and-toppings-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "finding": "Systems at end of life",
   "impact": "2 Planned",
   "timing": "Replace on cycle.",
   "url": "https://moyneross.com/technical/ventilation-systems#f-systems-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Membranes and coatings at age without leaks",
   "impact": "2 Planned",
   "timing": "Renewal on cycle.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-membranes-and-coatings-at-age-without-leaks"
  },
  {
   "grading": "lifecycle",
   "page": "water-conservation",
   "element": "Water Conservation",
   "section": "Environmental",
   "finding": "Fixtures at end of life",
   "impact": "2 Planned",
   "timing": "Replace with efficient fixtures.",
   "url": "https://moyneross.com/technical/water-conservation#f-fixtures-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "finding": "Pipework at end of life",
   "impact": "2 Planned",
   "timing": "Plan replacement, often riser by riser.",
   "url": "https://moyneross.com/technical/water-supply#f-pipework-at-end-of-life"
  },
  {
   "grading": "lifecycle",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Membrane at the end of its expected life, no leaks",
   "impact": "2 Planned",
   "timing": "Plan replacement with the insulation, falls and drainage.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-membrane-at-the-end-of-its-expected-life-no-leak"
  },
  {
   "grading": "deadline",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Thorough examination or periodic inspection due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-thorough-examination-or-periodic-inspection-due"
  },
  {
   "grading": "deadline",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Emergency call device on a network being retired",
   "impact": "4 Essential",
   "timing": "Migrate before the line is withdrawn.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-emergency-call-device-on-a-network-being-retired"
  },
  {
   "grading": "deadline",
   "page": "ancillary-structures",
   "element": "Ancillary Structures",
   "section": "External Elements",
   "finding": "Approval or compliance required by an authority",
   "impact": "3 Important",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/ancillary-structures#f-approval-or-compliance-required-by-an-authority"
  },
  {
   "grading": "deadline",
   "page": "architectural-and-decorative-features",
   "element": "Architectural & Decorative Features",
   "section": "Façades",
   "finding": "Ordinance finding of unsafe condition",
   "impact": "3 Important",
   "timing": "Timing set by the ordinance; protection immediately.",
   "url": "https://moyneross.com/technical/architectural-and-decorative-features#f-ordinance-finding-of-unsafe-condition"
  },
  {
   "grading": "deadline",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "finding": "Routine and long-interval inspections due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#f-routine-and-long-interval-inspections-due"
  },
  {
   "grading": "deadline",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "finding": "Defect warranty or tribunal deadlines",
   "impact": "4 Essential",
   "timing": "Act within the period.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#f-defect-warranty-or-tribunal-deadlines"
  },
  {
   "grading": "deadline",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "finding": "Periodic inspection or certification due",
   "impact": "4 Essential",
   "timing": "Timing set by the regulation or standard.",
   "url": "https://moyneross.com/technical/building-maintenance-units#f-periodic-inspection-or-certification-due"
  },
  {
   "grading": "deadline",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "finding": "Council notice requiring certification",
   "impact": "3 Important",
   "timing": "Timing set by the council.",
   "url": "https://moyneross.com/technical/canopies-and-awnings#f-council-notice-requiring-certification"
  },
  {
   "grading": "deadline",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "finding": "Refrigerant service restrictions in force for the refrigerant used",
   "impact": "4 Essential",
   "timing": "Plan replacement or conversion before the next major leak or repair.",
   "url": "https://moyneross.com/technical/central-cooling-plant#f-refrigerant-service-restrictions-in-force-for-th"
  },
  {
   "grading": "deadline",
   "page": "central-heating-plant",
   "element": "Central Heating Plant",
   "section": "Mechanical Services",
   "finding": "Pressure vessel inspection or gas safety check due",
   "impact": "4 Essential",
   "timing": "Timing set by the regulation.",
   "url": "https://moyneross.com/technical/central-heating-plant#f-pressure-vessel-inspection-or-gas-safety-check-d"
  },
  {
   "grading": "deadline",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Kitchen exhaust cleaning overdue against the required frequency",
   "impact": "4 Essential",
   "timing": "Clean by the due date.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-kitchen-exhaust-cleaning-overdue-against-the-req"
  },
  {
   "grading": "deadline",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Gas safety check due under landlord rules",
   "impact": "4 Essential",
   "timing": "Annual.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-gas-safety-check-due-under-landlord-rules"
  },
  {
   "grading": "deadline",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Combustible cladding identified where a regulator, scheme or order sets a remediation date",
   "impact": "4 Essential",
   "timing": "Timing set by the regulator; interim fire safety measures until done.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-combustible-cladding-identified-where-a-regulato"
  },
  {
   "grading": "deadline",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "finding": "Duct cleaning, suppression servicing or food inspection due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/commercial-kitchens#f-duct-cleaning-suppression-servicing-or-food-insp"
  },
  {
   "grading": "deadline",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "finding": "Rating, letting standard or lease obligation requiring upgrade by a date",
   "impact": "3 Important",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/commercial-office-areas#f-rating-letting-standard-or-lease-obligation-requ"
  },
  {
   "grading": "deadline",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "finding": "Fire door checks and certification due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/common-circulation-areas#f-fire-door-checks-and-certification-due"
  },
  {
   "grading": "deadline",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "finding": "Fire safety certification or capital works plan due",
   "impact": "3 Important",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/common-internal-areas#f-fire-safety-certification-or-capital-works-plan"
  },
  {
   "grading": "deadline",
   "page": "communications-security-and-specialist-systems",
   "element": "Communications, Security & Specialist Systems",
   "section": "Electrical Services",
   "finding": "Copper line retirement scheduled for devices still on copper",
   "impact": "4 Essential",
   "timing": "Migrate before the switch-off date.",
   "url": "https://moyneross.com/technical/communications-security-and-specialist-systems#f-copper-line-retirement-scheduled-for-devices-sti"
  },
  {
   "grading": "deadline",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "finding": "Upgrade required by an alteration approval or a complaint resolution",
   "impact": "4 Essential",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/disabled-access#f-upgrade-required-by-an-alteration-approval-or-a"
  },
  {
   "grading": "deadline",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Goods hoist registration, inspection or thorough examination due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-goods-hoist-registration-inspection-or-thorough"
  },
  {
   "grading": "deadline",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "finding": "Fire damper testing due",
   "impact": "4 Essential",
   "timing": "At the interval the standard sets.",
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#f-fire-damper-testing-due"
  },
  {
   "grading": "deadline",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "finding": "New-building or approval requirements for EV provision",
   "impact": "4 Essential",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#f-new-building-or-approval-requirements-for-ev-pro"
  },
  {
   "grading": "deadline",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "finding": "Fire stopping certification due with annual statements",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#f-fire-stopping-certification-due-with-annual-stat"
  },
  {
   "grading": "deadline",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "finding": "Periodic testing due",
   "impact": "4 Essential",
   "timing": "Six-monthly duration test in Australia; monthly functional and annual duration tests in Britain and the United States.",
   "url": "https://moyneross.com/technical/emergency-lighting#f-periodic-testing-due"
  },
  {
   "grading": "deadline",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "finding": "Mandatory testing due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/emergency-power#f-mandatory-testing-due"
  },
  {
   "grading": "deadline",
   "page": "energy-efficiency-upgrades",
   "element": "Energy Efficiency Upgrades",
   "section": "Environmental",
   "finding": "Building below a legal minimum for letting or facing performance standard penalties",
   "impact": "4 Essential",
   "timing": "By the regulatory date.",
   "url": "https://moyneross.com/technical/energy-efficiency-upgrades#f-building-below-a-legal-minimum-for-letting-or-fa"
  },
  {
   "grading": "deadline",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Periodic inspection or statutory test due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-periodic-inspection-or-statutory-test-due"
  },
  {
   "grading": "deadline",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "finding": "Lead-safe work requirements on pre-1978 housing in the United States before works",
   "impact": "3 Important",
   "timing": "Works must follow the rule; timing set by the works.",
   "url": "https://moyneross.com/technical/external-coating-systems#f-lead-safe-work-requirements-on-pre-1978-housing"
  },
  {
   "grading": "deadline",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "finding": "Pool barrier inspection or registration due",
   "impact": "3 Important",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#f-pool-barrier-inspection-or-registration-due"
  },
  {
   "grading": "deadline",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "finding": "Routine service, annual certification or domestic alarm requirements due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval or date.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#f-routine-service-annual-certification-or-domestic"
  },
  {
   "grading": "deadline",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "finding": "Weekly runs and annual flow tests due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/fire-pumping-systems#f-weekly-runs-and-annual-flow-tests-due"
  },
  {
   "grading": "deadline",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "finding": "Gas safety checks due in rented homes",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/fireplaces#f-gas-safety-checks-due-in-rented-homes"
  },
  {
   "grading": "deadline",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "finding": "By-law or tribunal orders on noise",
   "impact": "3 Important",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/flooring#f-by-law-or-tribunal-orders-on-noise"
  },
  {
   "grading": "deadline",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "finding": "Mine subsidence or heritage obligations requiring action by a date",
   "impact": "4 Essential",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/foundations#f-mine-subsidence-or-heritage-obligations-requirin"
  },
  {
   "grading": "deadline",
   "page": "gas-services",
   "element": "Gas Services",
   "section": "Hydraulic Services",
   "finding": "Landlord gas safety checks or periodic inspections due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/gas-services#f-landlord-gas-safety-checks-or-periodic-inspectio"
  },
  {
   "grading": "deadline",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "finding": "Façade ordinance finding of unsafe or safe with repair",
   "impact": "4 Essential",
   "timing": "Timing set by the ordinance.",
   "url": "https://moyneross.com/technical/glazing-systems#f-fa-ade-ordinance-finding-of-unsafe-or-safe-with"
  },
  {
   "grading": "deadline",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "finding": "Register review or management plan update due; no register in a workplace of the relevant era",
   "impact": "4 Essential",
   "timing": "At the required interval.",
   "url": "https://moyneross.com/technical/hazardous-materials#f-register-review-or-management-plan-update-due-no"
  },
  {
   "grading": "deadline",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "finding": "Tower not registered, no risk management plan, sampling or audit overdue",
   "impact": "4 Essential",
   "timing": "Comply immediately.",
   "url": "https://moyneross.com/technical/heat-rejection-plant#f-tower-not-registered-no-risk-management-plan-sam"
  },
  {
   "grading": "deadline",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "finding": "TMV servicing and Legionella testing due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#f-tmv-servicing-and-legionella-testing-due"
  },
  {
   "grading": "deadline",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "finding": "Routine service and flow testing due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#f-routine-service-and-flow-testing-due"
  },
  {
   "grading": "deadline",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Let commercial premises in England or Wales below the minimum energy efficiency standard, where insulation is part of the fix",
   "impact": "4 Essential",
   "timing": "Improve before the letting restrictions apply.",
   "url": "https://moyneross.com/technical/insulation#f-let-commercial-premises-in-england-or-wales-belo"
  },
  {
   "grading": "deadline",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "finding": "Integrated testing due under standards or certification",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/integrated-building-systems#f-integrated-testing-due-under-standards-or-certif"
  },
  {
   "grading": "deadline",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "finding": "Fire door and egress hardware inspections due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#f-fire-door-and-egress-hardware-inspections-due"
  },
  {
   "grading": "deadline",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "finding": "Fire door and emergency lighting checks due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/internal-stairwells#f-fire-door-and-emergency-lighting-checks-due"
  },
  {
   "grading": "deadline",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "finding": "Asbestos register review due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#f-asbestos-register-review-due"
  },
  {
   "grading": "deadline",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "finding": "Tenancy or sale requirements for gas or electrical safety",
   "impact": "3 Important",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/kitchen#f-tenancy-or-sale-requirements-for-gas-or-electric"
  },
  {
   "grading": "deadline",
   "page": "landscaping-and-irrigation",
   "element": "Landscaping & Irrigation",
   "section": "External Elements",
   "finding": "Irrigation backflow testing due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/landscaping-and-irrigation#f-irrigation-backflow-testing-due"
  },
  {
   "grading": "deadline",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "finding": "Statutory lift inspections",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#f-statutory-lift-inspections"
  },
  {
   "grading": "deadline",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "finding": "Inspection and testing due",
   "impact": "4 Essential",
   "timing": "At the interval the standard sets.",
   "url": "https://moyneross.com/technical/lightning-protection#f-inspection-and-testing-due"
  },
  {
   "grading": "deadline",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "finding": "Seismic retrofit required by ordinance",
   "impact": "4 Essential",
   "timing": "By the ordinance date.",
   "url": "https://moyneross.com/technical/load-bearing-masonry#f-seismic-retrofit-required-by-ordinance"
  },
  {
   "grading": "deadline",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "finding": "Statutory inspections of doors, lifts or equipment due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#f-statutory-inspections-of-doors-lifts-or-equipmen"
  },
  {
   "grading": "deadline",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "finding": "Smoke control testing due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#f-smoke-control-testing-due"
  },
  {
   "grading": "deadline",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "finding": "R22 equipment where servicing is restricted",
   "impact": "4 Essential",
   "timing": "Replace before the next major repair.",
   "url": "https://moyneross.com/technical/localised-hvac#f-r22-equipment-where-servicing-is-restricted"
  },
  {
   "grading": "deadline",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "finding": "Periodic inspection and testing due",
   "impact": "4 Essential",
   "timing": "At the interval set by the regulation or standard.",
   "url": "https://moyneross.com/technical/main-electrical-supply#f-periodic-inspection-and-testing-due"
  },
  {
   "grading": "deadline",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "finding": "Access or security requirements triggered by works or a complaint",
   "impact": "3 Important",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#f-access-or-security-requirements-triggered-by-wor"
  },
  {
   "grading": "deadline",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "finding": "Certification of anchors, ladders or platforms due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/maintenance-access-areas#f-certification-of-anchors-ladders-or-platforms-du"
  },
  {
   "grading": "deadline",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "finding": "Register reviews and statutory inspections due",
   "impact": "4 Essential",
   "timing": "At the required interval.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#f-register-reviews-and-statutory-inspections-due"
  },
  {
   "grading": "deadline",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "finding": "Fire certification requiring rectification",
   "impact": "3 Important",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/partitioning-systems#f-fire-certification-requiring-rectification"
  },
  {
   "grading": "deadline",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Periodic inspection, thorough examination or registration due",
   "impact": "4 Essential",
   "timing": "At the prescribed date.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-periodic-inspection-thorough-examination-or-regi"
  },
  {
   "grading": "deadline",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Emergency phone on a network being retired",
   "impact": "4 Essential",
   "timing": "Migrate before the line is withdrawn.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-emergency-phone-on-a-network-being-retired"
  },
  {
   "grading": "deadline",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "finding": "Fire door checks and annual certification due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/passive-fire-protection#f-fire-door-checks-and-annual-certification-due"
  },
  {
   "grading": "deadline",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "finding": "Accessible parking or routes not compliant",
   "impact": "3 Important",
   "timing": "Rectify as required.",
   "url": "https://moyneross.com/technical/pavements-and-hardstand#f-accessible-parking-or-routes-not-compliant"
  },
  {
   "grading": "deadline",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "finding": "Detector calibration and lifting equipment certification due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/plant-rooms#f-detector-calibration-and-lifting-equipment-certi"
  },
  {
   "grading": "deadline",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Annual parapet observation due (New York)",
   "impact": "4 Essential",
   "timing": "Annual.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-annual-parapet-observation-due-new-york"
  },
  {
   "grading": "deadline",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Façade inspection under a city ordinance due or overdue",
   "impact": "4 Essential",
   "timing": "Inspect and file by the due date.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-fa-ade-inspection-under-a-city-ordinance-due-or"
  },
  {
   "grading": "deadline",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "finding": "Routine service due",
   "impact": "4 Essential",
   "timing": "Six-monthly in Australia; annually in Britain and the United States, with monthly checks.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#f-routine-service-due"
  },
  {
   "grading": "deadline",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "finding": "Periodic inspection and testing due",
   "impact": "4 Essential",
   "timing": "At the interval set by the regulation or standard.",
   "url": "https://moyneross.com/technical/power-distribution#f-periodic-inspection-and-testing-due"
  },
  {
   "grading": "deadline",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "finding": "Fixture numbers below code for current occupancy",
   "impact": "3 Important",
   "timing": "Before occupancy increases or as required.",
   "url": "https://moyneross.com/technical/public-amenities#f-fixture-numbers-below-code-for-current-occupancy"
  },
  {
   "grading": "deadline",
   "page": "recreational-facilities",
   "element": "Recreational Facilities",
   "section": "External Elements",
   "finding": "Periodic inspections due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/recreational-facilities#f-periodic-inspections-due"
  },
  {
   "grading": "deadline",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "finding": "Rental minimum standards, smoke alarm laws or brand deadlines",
   "impact": "3 Important",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#f-rental-minimum-standards-smoke-alarm-laws-or-bra"
  },
  {
   "grading": "deadline",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "finding": "Lease, health or trade waste obligations requiring works",
   "impact": "3 Important",
   "timing": "By the required date.",
   "url": "https://moyneross.com/technical/retail-tenancies#f-lease-health-or-trade-waste-obligations-requirin"
  },
  {
   "grading": "deadline",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Asbestos cement roof with no register: a workplace in Australia, a non-domestic building in the United Kingdom",
   "impact": "4 Essential",
   "timing": "The duty applies now; register and plan before any roof work.",
   "url": "https://moyneross.com/technical/roof-coverings#f-asbestos-no-register"
  },
  {
   "grading": "deadline",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Periodic inspection or recertification due",
   "impact": "4 Essential",
   "timing": "Inspect by the due date.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-periodic-inspection-or-recertification-due"
  },
  {
   "grading": "deadline",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Fixed ladders above the height at which the asset’s market requires ladder safety or personal fall arrest, without either",
   "impact": "4 Essential",
   "timing": "Fit ladder safety systems before 18 November 2036, sooner when replaced.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-fixed-ladders-over-24-feet-7-3-m-in-the-united-s"
  },
  {
   "grading": "deadline",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "finding": "Fire safety inspections due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/service-corridors#f-fire-safety-inspections-due"
  },
  {
   "grading": "deadline",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Smoke vent testing overdue under the fire safety maintenance regime",
   "impact": "4 Essential",
   "timing": "Test by the due date.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-smoke-vent-testing-overdue-under-the-fire-safety"
  },
  {
   "grading": "deadline",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "finding": "Routine and integrated testing due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/smoke-management-systems#f-routine-and-integrated-testing-due"
  },
  {
   "grading": "deadline",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "finding": "Statutory testing, certification or accreditation due",
   "impact": "3 Important",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#f-statutory-testing-certification-or-accreditation"
  },
  {
   "grading": "deadline",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "finding": "Statutory inspections of pools or lifts due",
   "impact": "3 Important",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#f-statutory-inspections-of-pools-or-lifts-due"
  },
  {
   "grading": "deadline",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "finding": "Pool barrier inspection or registration due",
   "impact": "4 Essential",
   "timing": "By the regulatory date.",
   "url": "https://moyneross.com/technical/specialist-hydraulics#f-pool-barrier-inspection-or-registration-due"
  },
  {
   "grading": "deadline",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "Halon, HFC or PFAS foam requiring decommissioning or replacement under rules",
   "impact": "4 Essential",
   "timing": "By the regulatory date.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-halon-hfc-or-pfas-foam-requiring-decommissioning"
  },
  {
   "grading": "deadline",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "Servicing and integrity testing due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-servicing-and-integrity-testing-due"
  },
  {
   "grading": "deadline",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "finding": "Dangerous goods notification or manifest due",
   "impact": "3 Important",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/storage-and-archive-areas#f-dangerous-goods-notification-or-manifest-due"
  },
  {
   "grading": "deadline",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "finding": "On-site detention maintenance required by title or council",
   "impact": "4 Essential",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/stormwater-drainage#f-on-site-detention-maintenance-required-by-title"
  },
  {
   "grading": "deadline",
   "page": "structural-core",
   "element": "Structural Core",
   "section": "Superstructure",
   "finding": "Seismic retrofit required by ordinance",
   "impact": "4 Essential",
   "timing": "By the ordinance date.",
   "url": "https://moyneross.com/technical/structural-core#f-seismic-retrofit-required-by-ordinance"
  },
  {
   "grading": "deadline",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "finding": "Statutory car park or milestone inspection due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/structural-frame#f-statutory-car-park-or-milestone-inspection-due"
  },
  {
   "grading": "deadline",
   "page": "sub-metering",
   "element": "Sub-metering",
   "section": "Environmental",
   "finding": "Billing with unapproved meters or under embedded network rules not met",
   "impact": "4 Essential",
   "timing": "Rectify to the legal requirement.",
   "url": "https://moyneross.com/technical/sub-metering#f-billing-with-unapproved-meters-or-under-embedded"
  },
  {
   "grading": "deadline",
   "page": "trade-waste-systems",
   "element": "Trade Waste Systems",
   "section": "Hydraulic Services",
   "finding": "Utility notice or agreement requiring upgrade or sampling",
   "impact": "4 Essential",
   "timing": "By the utility's date.",
   "url": "https://moyneross.com/technical/trade-waste-systems#f-utility-notice-or-agreement-requiring-upgrade-or"
  },
  {
   "grading": "deadline",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "finding": "Kitchen exhaust cleaning, fume cupboard or LEV testing due",
   "impact": "4 Essential",
   "timing": "At the prescribed interval.",
   "url": "https://moyneross.com/technical/ventilation-systems#f-kitchen-exhaust-cleaning-fume-cupboard-or-lev-te"
  },
  {
   "grading": "deadline",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "California exterior elevated element inspection due; strata order",
   "impact": "4 Essential",
   "timing": "Timing set by the statute or order.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-california-exterior-elevated-element-inspection"
  },
  {
   "grading": "deadline",
   "page": "water-conservation",
   "element": "Water Conservation",
   "section": "Environmental",
   "finding": "Water restrictions or rating requirements",
   "impact": "4 Essential",
   "timing": "As required.",
   "url": "https://moyneross.com/technical/water-conservation#f-water-restrictions-or-rating-requirements"
  },
  {
   "grading": "deadline",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "finding": "Backflow testing due; lead service line replacement under a programme",
   "impact": "4 Essential",
   "timing": "At the prescribed interval or date.",
   "url": "https://moyneross.com/technical/water-supply#f-backflow-testing-due-lead-service-line-replaceme"
  },
  {
   "grading": "check",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "No access audit; no evacuation arrangement for users",
   "impact": "3 Important",
   "timing": "Assess with an access consultant and the fire strategy.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-no-access-audit-no-evacuation-arrangement-for-us"
  },
  {
   "grading": "check",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "finding": "No hygiene inspection; outside air not measured",
   "impact": "2 Planned",
   "timing": "Inspect and measure.",
   "url": "https://moyneross.com/technical/air-handling-units#f-no-hygiene-inspection-outside-air-not-measured"
  },
  {
   "grading": "check",
   "page": "ancillary-structures",
   "element": "Ancillary Structures",
   "section": "External Elements",
   "finding": "Unapproved structures; no engineering",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/ancillary-structures#f-unapproved-structures-no-engineering"
  },
  {
   "grading": "check",
   "page": "architectural-and-decorative-features",
   "element": "Architectural & Decorative Features",
   "section": "Façades",
   "finding": "Heritage façade over a footpath with no close-up survey on record",
   "impact": "2 Planned",
   "timing": "Close-up hammer survey before sizing works.",
   "url": "https://moyneross.com/technical/architectural-and-decorative-features#f-heritage-fa-ade-over-a-footpath-with-no-close-up"
  },
  {
   "grading": "check",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "finding": "No design certificate; use changed; no recent flow test",
   "impact": "3 Important",
   "timing": "Design review and testing.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#f-no-design-certificate-use-changed-no-recent-flow"
  },
  {
   "grading": "check",
   "page": "basement-cellars-and-retaining-walls",
   "element": "Basement, Cellars & Retaining Walls",
   "section": "Substructure",
   "finding": "Walls without design approval; radon untested in affected areas",
   "impact": "3 Important",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/basement-cellars-and-retaining-walls#f-walls-without-design-approval-radon-untested-in"
  },
  {
   "grading": "check",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "finding": "Moisture readings elevated with no visible damage",
   "impact": "3 Important",
   "timing": "Investigate further.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#f-moisture-readings-elevated-with-no-visible-damag"
  },
  {
   "grading": "check",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "finding": "Unit more than ten years old with no major inspection; coverage of the current façade unknown",
   "impact": "3 Important",
   "timing": "Major inspection and coverage study.",
   "url": "https://moyneross.com/technical/building-maintenance-units#f-unit-more-than-ten-years-old-with-no-major-inspe"
  },
  {
   "grading": "check",
   "page": "building-management-and-control-system",
   "element": "Building Management & Control System (BMCS)",
   "section": "Mechanical Services",
   "finding": "No documentation or security assessment",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/building-management-and-control-system#f-no-documentation-or-security-assessment"
  },
  {
   "grading": "check",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "finding": "Tied awning more than ten years old with no engineer's certificate on record",
   "impact": "2 Planned",
   "timing": "Structural inspection with opening up of anchorages.",
   "url": "https://moyneross.com/technical/canopies-and-awnings#f-tied-awning-more-than-ten-years-old-with-no-engi"
  },
  {
   "grading": "check",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "finding": "No tube testing, oil analysis or load study on record; capacity questioned after tenancy changes",
   "impact": "2 Planned",
   "timing": "Plant condition and load assessment before sizing works.",
   "url": "https://moyneross.com/technical/central-cooling-plant#f-no-tube-testing-oil-analysis-or-load-study-on-re"
  },
  {
   "grading": "check",
   "page": "central-heating-plant",
   "element": "Central Heating Plant",
   "section": "Mechanical Services",
   "finding": "No water treatment records; no assessment of heat pump readiness",
   "impact": "2 Planned",
   "timing": "Assess before replacing.",
   "url": "https://moyneross.com/technical/central-heating-plant#f-no-water-treatment-records-no-assessment-of-heat"
  },
  {
   "grading": "check",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Working flue with no inspection record; appliance changed",
   "impact": "2 Planned",
   "timing": "Inspect and test before use.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-working-flue-with-no-inspection-record-appliance"
  },
  {
   "grading": "check",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Combustible cladding identified with no order yet",
   "impact": "2 Planned",
   "timing": "External wall fire risk assessment by a fire engineer sets whether and how soon it must be remediated.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-combustible-cladding-identified-with-no-order-ye"
  },
  {
   "grading": "check",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Face-sealed system on framing of the at-risk era with no investigation on record",
   "impact": "2 Planned",
   "timing": "Probe and open up before sizing works.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-face-sealed-system-on-framing-of-the-at-risk-era"
  },
  {
   "grading": "check",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "finding": "Services capacity unknown for the current menu",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/commercial-kitchens#f-services-capacity-unknown-for-the-current-menu"
  },
  {
   "grading": "check",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "finding": "Grade, air, light and amenities never assessed against the market",
   "impact": "2 Planned",
   "timing": "Assess fitness for purpose.",
   "url": "https://moyneross.com/technical/commercial-office-areas#f-grade-air-light-and-amenities-never-assessed-aga"
  },
  {
   "grading": "check",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "finding": "No fire door register; layout changes unreviewed",
   "impact": "2 Planned",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/common-circulation-areas#f-no-fire-door-register-layout-changes-unreviewed"
  },
  {
   "grading": "check",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "finding": "No capital works plan or door survey",
   "impact": "2 Planned",
   "timing": "Prepare.",
   "url": "https://moyneross.com/technical/common-internal-areas#f-no-capital-works-plan-or-door-survey"
  },
  {
   "grading": "check",
   "page": "communications-security-and-specialist-systems",
   "element": "Communications, Security & Specialist Systems",
   "section": "Electrical Services",
   "finding": "Line types unknown; no security assessment",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/communications-security-and-specialist-systems#f-line-types-unknown-no-security-assessment"
  },
  {
   "grading": "check",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "finding": "No access audit; alterations planned",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/disabled-access#f-no-access-audit-alterations-planned"
  },
  {
   "grading": "check",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Forklift weights unknown; vehicle movements unknown; asbestos status unknown",
   "impact": "3 Important",
   "timing": "Establish before sizing works.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-forklift-weights-unknown-vehicle-movements-unkno"
  },
  {
   "grading": "check",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "finding": "No hygiene inspection; fire damper register incomplete",
   "impact": "2 Planned",
   "timing": "Inspect.",
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#f-no-hygiene-inspection-fire-damper-register-incom"
  },
  {
   "grading": "check",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "finding": "No capacity study; tenant or resident demand rising",
   "impact": "2 Planned",
   "timing": "Assess capacity.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#f-no-capacity-study-tenant-or-resident-demand-risi"
  },
  {
   "grading": "check",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "finding": "No capacity or fire stopping records",
   "impact": "2 Planned",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#f-no-capacity-or-fire-stopping-records"
  },
  {
   "grading": "check",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "finding": "No test records; layout not checked after fit-outs",
   "impact": "3 Important",
   "timing": "Test every fitting and review coverage.",
   "url": "https://moyneross.com/technical/emergency-lighting#f-no-test-records-layout-not-checked-after-fit-out"
  },
  {
   "grading": "check",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "finding": "No load bank test or load study",
   "impact": "3 Important",
   "timing": "Test and study.",
   "url": "https://moyneross.com/technical/emergency-power#f-no-load-bank-test-or-load-study"
  },
  {
   "grading": "check",
   "page": "energy-efficiency-upgrades",
   "element": "Energy Efficiency Upgrades",
   "section": "Environmental",
   "finding": "No audit; ratings unknown",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/energy-efficiency-upgrades#f-no-audit-ratings-unknown"
  },
  {
   "grading": "check",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "No audit, no injury analysis, duty unknown, asbestos status unknown",
   "impact": "3 Important",
   "timing": "Audit before sizing works.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-no-audit-no-injury-analysis-duty-unknown-asbesto"
  },
  {
   "grading": "check",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "finding": "Pre-1970 paint layers with unknown lead content; coating on concrete with unknown carbonation depth",
   "impact": "2 Planned",
   "timing": "Test before specifying works.",
   "url": "https://moyneross.com/technical/external-coating-systems#f-pre-1970-paint-layers-with-unknown-lead-content"
  },
  {
   "grading": "check",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "finding": "No gate safety test records; signage not reviewed after changes",
   "impact": "2 Planned",
   "timing": "Inspect.",
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#f-no-gate-safety-test-records-signage-not-reviewed"
  },
  {
   "grading": "check",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "finding": "No interface test on record; system not reviewed after fit-outs",
   "impact": "3 Important",
   "timing": "Audit and full integrated test.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#f-no-interface-test-on-record-system-not-reviewed"
  },
  {
   "grading": "check",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "finding": "No flow test record; town main pressure not checked recently",
   "impact": "3 Important",
   "timing": "Flow test and supply check.",
   "url": "https://moyneross.com/technical/fire-pumping-systems#f-no-flow-test-record-town-main-pressure-not-check"
  },
  {
   "grading": "check",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "finding": "Service history unknown",
   "impact": "3 Important",
   "timing": "Service and test.",
   "url": "https://moyneross.com/technical/fireplaces#f-service-history-unknown"
  },
  {
   "grading": "check",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "finding": "Moisture or asbestos status unknown",
   "impact": "2 Planned",
   "timing": "Test before works.",
   "url": "https://moyneross.com/technical/flooring#f-moisture-or-asbestos-status-unknown"
  },
  {
   "grading": "check",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "finding": "Cracks of unknown cause; trees near a building on clay",
   "impact": "3 Important",
   "timing": "Monitor for twelve months and investigate.",
   "url": "https://moyneross.com/technical/foundations#f-cracks-of-unknown-cause-trees-near-a-building-on"
  },
  {
   "grading": "check",
   "page": "gas-services",
   "element": "Gas Services",
   "section": "Hydraulic Services",
   "finding": "Installation never tested; alterations unrecorded",
   "impact": "3 Important",
   "timing": "Tightness test and inspection.",
   "url": "https://moyneross.com/technical/gas-services#f-installation-never-tested-alterations-unrecorded"
  },
  {
   "grading": "check",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "finding": "SSG with no adhesion test record; toughened glass at height with no heat-soak record; recurring leaks of unknown path",
   "impact": "2 Planned",
   "timing": "Test before sizing works.",
   "url": "https://moyneross.com/technical/glazing-systems#f-ssg-with-no-adhesion-test-record-toughened-glass"
  },
  {
   "grading": "check",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "finding": "Areas not accessed; refurbishment planned",
   "impact": "3 Important",
   "timing": "Survey before works.",
   "url": "https://moyneross.com/technical/hazardous-materials#f-areas-not-accessed-refurbishment-planned"
  },
  {
   "grading": "check",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "finding": "Condenser capacity in doubt on hot days",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/heat-rejection-plant#f-condenser-capacity-in-doubt-on-hot-days"
  },
  {
   "grading": "check",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "finding": "No risk assessment or temperature records",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#f-no-risk-assessment-or-temperature-records"
  },
  {
   "grading": "check",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "finding": "No flow test on record",
   "impact": "3 Important",
   "timing": "Flow test.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#f-no-flow-test-on-record"
  },
  {
   "grading": "check",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Insulation upgrade planned without a condensation risk assessment",
   "impact": "2 Planned",
   "timing": "Assess the build-up before the work is specified.",
   "url": "https://moyneross.com/technical/insulation#f-insulation-upgrade-planned-without-a-condensatio"
  },
  {
   "grading": "check",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Possible vermiculite or spray foam with no records",
   "impact": "2 Planned",
   "timing": "Identify and assess first.",
   "url": "https://moyneross.com/technical/insulation#f-possible-vermiculite-or-spray-foam-with-no-recor"
  },
  {
   "grading": "check",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "finding": "No integrated test since major changes",
   "impact": "2 Planned",
   "timing": "Test.",
   "url": "https://moyneross.com/technical/integrated-building-systems#f-no-integrated-test-since-major-changes"
  },
  {
   "grading": "check",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "finding": "No door schedule or interface test",
   "impact": "2 Planned",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#f-no-door-schedule-or-interface-test"
  },
  {
   "grading": "check",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "finding": "No review of locking and re-entry",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/internal-stairwells#f-no-review-of-locking-and-re-entry"
  },
  {
   "grading": "check",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "finding": "Hazardous content unknown in older finishes",
   "impact": "2 Planned",
   "timing": "Sample before works.",
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#f-hazardous-content-unknown-in-older-finishes"
  },
  {
   "grading": "check",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "finding": "Gas and electrical compliance unknown",
   "impact": "2 Planned",
   "timing": "Inspect.",
   "url": "https://moyneross.com/technical/kitchen#f-gas-and-electrical-compliance-unknown"
  },
  {
   "grading": "check",
   "page": "landscaping-and-irrigation",
   "element": "Landscaping & Irrigation",
   "section": "External Elements",
   "finding": "No tree risk assessment",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/landscaping-and-irrigation#f-no-tree-risk-assessment"
  },
  {
   "grading": "check",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "finding": "Machine room conditions unknown",
   "impact": "3 Important",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#f-machine-room-conditions-unknown"
  },
  {
   "grading": "check",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "finding": "No column testing; PCB status unknown; no lux survey",
   "impact": "2 Planned",
   "timing": "Inspect and survey.",
   "url": "https://moyneross.com/technical/lighting#f-no-column-testing-pcb-status-unknown-no-lux-surv"
  },
  {
   "grading": "check",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "finding": "No documentation; energy data not reviewed",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/lighting-control-system#f-no-documentation-energy-data-not-reviewed"
  },
  {
   "grading": "check",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "finding": "No risk assessment; ESE system; no records",
   "impact": "3 Important",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/lightning-protection#f-no-risk-assessment-ese-system-no-records"
  },
  {
   "grading": "check",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "finding": "Alterations with no engineering on record",
   "impact": "3 Important",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/load-bearing-masonry#f-alterations-with-no-engineering-on-record"
  },
  {
   "grading": "check",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "finding": "No traffic management plan or capacity review",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#f-no-traffic-management-plan-or-capacity-review"
  },
  {
   "grading": "check",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "finding": "Glass types and smoke design unknown",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#f-glass-types-and-smoke-design-unknown"
  },
  {
   "grading": "check",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "finding": "Refrigerant type unknown; VRF compliance unknown",
   "impact": "2 Planned",
   "timing": "Inspect.",
   "url": "https://moyneross.com/technical/localised-hvac#f-refrigerant-type-unknown-vrf-compliance-unknown"
  },
  {
   "grading": "check",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "finding": "Capacity unknown for electrification or EV charging; no recent thermography",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/main-electrical-supply#f-capacity-unknown-for-electrification-or-ev-charg"
  },
  {
   "grading": "check",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "finding": "No access audit; door safety unchecked",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#f-no-access-audit-door-safety-unchecked"
  },
  {
   "grading": "check",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "finding": "No access audit",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/maintenance-access-areas#f-no-access-audit"
  },
  {
   "grading": "check",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "finding": "Tie-era cavity wall in exposed or marine position with no record of tie condition; cracks of unknown cause; damp of unknown source",
   "impact": "2 Planned",
   "timing": "Investigate first; size the works from what the investigation finds.",
   "url": "https://moyneross.com/technical/masonry-brickwork#f-tie-era-cavity-wall-in-exposed-or-marine-positio"
  },
  {
   "grading": "check",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "finding": "No registers or building safety file",
   "impact": "3 Important",
   "timing": "Compile.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#f-no-registers-or-building-safety-file"
  },
  {
   "grading": "check",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "finding": "Rated partitions not identified",
   "impact": "2 Planned",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/partitioning-systems#f-rated-partitions-not-identified"
  },
  {
   "grading": "check",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "No condition audit; modernisation history unknown; asbestos status unknown",
   "impact": "3 Important",
   "timing": "Audit before sizing works.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-no-condition-audit-modernisation-history-unknown"
  },
  {
   "grading": "check",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "finding": "No fire strategy; compartmentation unknown",
   "impact": "3 Important",
   "timing": "Fire strategy and compartmentation survey.",
   "url": "https://moyneross.com/technical/passive-fire-protection#f-no-fire-strategy-compartmentation-unknown"
  },
  {
   "grading": "check",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "finding": "Pavement capacity for current traffic unknown",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/pavements-and-hardstand#f-pavement-capacity-for-current-traffic-unknown"
  },
  {
   "grading": "check",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "finding": "Plant room conditions never assessed",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/plant-rooms#f-plant-room-conditions-never-assessed"
  },
  {
   "grading": "check",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Screens with no engineering; parapet used as roof edge protection with unknown height",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-screens-with-no-engineering-parapet-used-as-roof"
  },
  {
   "grading": "check",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "finding": "No register; placement not reviewed after fit-outs",
   "impact": "3 Important",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#f-no-register-placement-not-reviewed-after-fit-out"
  },
  {
   "grading": "check",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "finding": "No periodic inspection on record; wiring type unknown",
   "impact": "3 Important",
   "timing": "Inspect and test.",
   "url": "https://moyneross.com/technical/power-distribution#f-no-periodic-inspection-on-record-wiring-type-unk"
  },
  {
   "grading": "check",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "finding": "Occupancy against fixtures unknown",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/public-amenities#f-occupancy-against-fixtures-unknown"
  },
  {
   "grading": "check",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "finding": "No backup power or alarm monitoring; capacity unknown",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/pumping-systems#f-no-backup-power-or-alarm-monitoring-capacity-unk"
  },
  {
   "grading": "check",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Storm-only leaks of unknown cause; roof altered since design",
   "impact": "3 Important",
   "timing": "Capacity check against current rainfall data before sizing works.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-storm-only-leaks-of-unknown-cause-roof-altered-s"
  },
  {
   "grading": "check",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Siphonic system with no maintenance records",
   "impact": "3 Important",
   "timing": "Inspect outlets and verify the design before relying on it.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-siphonic-system-with-no-maintenance-records"
  },
  {
   "grading": "check",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Asbestos cement gutters or downpipes of unknown status",
   "impact": "3 Important",
   "timing": "Identify before any work.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-asbestos-cement-gutters-or-downpipes-of-unknown"
  },
  {
   "grading": "check",
   "page": "recreational-facilities",
   "element": "Recreational Facilities",
   "section": "External Elements",
   "finding": "No inspection records",
   "impact": "2 Planned",
   "timing": "Inspect.",
   "url": "https://moyneross.com/technical/recreational-facilities#f-no-inspection-records"
  },
  {
   "grading": "check",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "finding": "No unit sample inspected",
   "impact": "2 Planned",
   "timing": "Inspect.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#f-no-unit-sample-inspected"
  },
  {
   "grading": "check",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "finding": "Services capacity per tenancy unknown",
   "impact": "2 Planned",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/retail-tenancies#f-services-capacity-per-tenancy-unknown"
  },
  {
   "grading": "check",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Sheet that may be asbestos cement, with no register entry",
   "impact": "3 Important",
   "timing": "Identify by sampling before any work; it sets the method and the cost.",
   "url": "https://moyneross.com/technical/roof-coverings#f-suspected-asbestos-cement"
  },
  {
   "grading": "check",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Water entering at a point not yet found",
   "impact": "3 Important",
   "timing": "Investigate before sizing works.",
   "url": "https://moyneross.com/technical/roof-coverings#f-unknown-water-entry"
  },
  {
   "grading": "check",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "No system on a roof that needs maintenance access",
   "impact": "3 Important",
   "timing": "Design the system to the work on the roof.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-no-system-on-a-roof-that-needs-maintenance-acces"
  },
  {
   "grading": "check",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Fire-damaged members never assessed",
   "impact": "3 Important",
   "timing": "Engineer's assessment before reliance.",
   "url": "https://moyneross.com/technical/roof-structure#f-fire-damaged-members-never-assessed"
  },
  {
   "grading": "check",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Plant or solar added with no engineering; RAAC possible from the building's era and type",
   "impact": "3 Important",
   "timing": "Assess before sizing works.",
   "url": "https://moyneross.com/technical/roof-structure#f-plant-or-solar-added-with-no-engineering-raac-po"
  },
  {
   "grading": "check",
   "page": "sanitary-and-drainage-systems",
   "element": "Sanitary & Drainage Systems",
   "section": "Hydraulic Services",
   "finding": "No CCTV; repeated blockages of unknown cause",
   "impact": "3 Important",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/sanitary-and-drainage-systems#f-no-cctv-repeated-blockages-of-unknown-cause"
  },
  {
   "grading": "check",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "finding": "Sealants on a building of the PCB era with no hazardous materials survey",
   "impact": "2 Planned",
   "timing": "Test before any removal; sets the method of the programme.",
   "url": "https://moyneross.com/technical/sealants-and-joints#f-sealants-on-a-building-of-the-pcb-era-with-no-ha"
  },
  {
   "grading": "check",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "finding": "Egress role of corridors not documented",
   "impact": "2 Planned",
   "timing": "Review.",
   "url": "https://moyneross.com/technical/service-corridors#f-egress-role-of-corridors-not-documented"
  },
  {
   "grading": "check",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Overhead glass of unknown type in an atrium",
   "impact": "2 Planned",
   "timing": "Identify glass type.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-overhead-glass-of-unknown-type-in-an-atrium"
  },
  {
   "grading": "check",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "finding": "Slab capacity or flatness unknown for a new use",
   "impact": "3 Important",
   "timing": "Survey and assess.",
   "url": "https://moyneross.com/technical/slab-on-ground#f-slab-capacity-or-flatness-unknown-for-a-new-use"
  },
  {
   "grading": "check",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "finding": "No integrated test since changes",
   "impact": "3 Important",
   "timing": "Integrated test.",
   "url": "https://moyneross.com/technical/smoke-management-systems#f-no-integrated-test-since-changes"
  },
  {
   "grading": "check",
   "page": "solar-photovoltaic-systems",
   "element": "Solar Photovoltaic (PV) Systems",
   "section": "Electrical Services",
   "finding": "Roof structure not assessed; PPA terms unknown",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/solar-photovoltaic-systems#f-roof-structure-not-assessed-ppa-terms-unknown"
  },
  {
   "grading": "check",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "finding": "Use changed without a review of services",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#f-use-changed-without-a-review-of-services"
  },
  {
   "grading": "check",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "finding": "Feature undocumented",
   "impact": "2 Planned",
   "timing": "Record and assess.",
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#f-feature-undocumented"
  },
  {
   "grading": "check",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "finding": "No water management plan; no barrier certificate",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/specialist-hydraulics#f-no-water-management-plan-no-barrier-certificate"
  },
  {
   "grading": "check",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "Design basis unknown after change of use",
   "impact": "3 Important",
   "timing": "Review.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-design-basis-unknown-after-change-of-use"
  },
  {
   "grading": "check",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "finding": "Storage loads and contents unknown",
   "impact": "2 Planned",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/storage-and-archive-areas#f-storage-loads-and-contents-unknown"
  },
  {
   "grading": "check",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "finding": "No drawings; detention obligations unknown",
   "impact": "3 Important",
   "timing": "Investigate.",
   "url": "https://moyneross.com/technical/stormwater-drainage#f-no-drawings-detention-obligations-unknown"
  },
  {
   "grading": "check",
   "page": "structural-core",
   "element": "Structural Core",
   "section": "Superstructure",
   "finding": "Lateral system unknown; seismic adequacy unassessed in seismic regions",
   "impact": "3 Important",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/structural-core#f-lateral-system-unknown-seismic-adequacy-unassess"
  },
  {
   "grading": "check",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "finding": "Problem concretes possible; alterations unengineered; no survey of a car park",
   "impact": "3 Important",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/structural-frame#f-problem-concretes-possible-alterations-unenginee"
  },
  {
   "grading": "check",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "finding": "No timber pest inspection; inaccessible sub-floor",
   "impact": "3 Important",
   "timing": "Inspect.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#f-no-timber-pest-inspection-inaccessible-sub-floor"
  },
  {
   "grading": "check",
   "page": "sub-metering",
   "element": "Sub-metering",
   "section": "Environmental",
   "finding": "No reconciliation or metering schedule",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/sub-metering#f-no-reconciliation-or-metering-schedule"
  },
  {
   "grading": "check",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "finding": "No sample inspection; controls data unavailable",
   "impact": "2 Planned",
   "timing": "Sample inspection and controls audit.",
   "url": "https://moyneross.com/technical/terminal-units#f-no-sample-inspection-controls-data-unavailable"
  },
  {
   "grading": "check",
   "page": "trade-waste-systems",
   "element": "Trade Waste Systems",
   "section": "Hydraulic Services",
   "finding": "No trade waste agreement; capacity not checked after tenancy changes",
   "impact": "2 Planned",
   "timing": "Assess.",
   "url": "https://moyneross.com/technical/trade-waste-systems#f-no-trade-waste-agreement-capacity-not-checked-af"
  },
  {
   "grading": "check",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "finding": "Design loads unknown for current or proposed use",
   "impact": "3 Important",
   "timing": "Assess capacity.",
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#f-design-loads-unknown-for-current-or-proposed-use"
  },
  {
   "grading": "check",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "finding": "No records for safety-related systems",
   "impact": "2 Planned",
   "timing": "Test and inspect.",
   "url": "https://moyneross.com/technical/ventilation-systems#f-no-records-for-safety-related-systems"
  },
  {
   "grading": "check",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Balustrades below current height or with climbable rails, compliant when built; monolithic toughened glass balustrades at height",
   "impact": "3 Important",
   "timing": "Assess risk by use and fall height; upgrade where children use the space or where the risk warrants.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-balustrades-below-current-height-or-with-climbab"
  },
  {
   "grading": "check",
   "page": "water-conservation",
   "element": "Water Conservation",
   "section": "Environmental",
   "finding": "No water audit",
   "impact": "2 Planned",
   "timing": "Audit.",
   "url": "https://moyneross.com/technical/water-conservation#f-no-water-audit"
  },
  {
   "grading": "check",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "finding": "Pipe materials unknown; no backflow register",
   "impact": "3 Important",
   "timing": "Survey.",
   "url": "https://moyneross.com/technical/water-supply#f-pipe-materials-unknown-no-backflow-register"
  },
  {
   "grading": "check",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Planted or paved roof with leaks and no access to the membrane",
   "impact": "3 Important",
   "timing": "Locate the breach (electronic leak detection) before lifting the build-up.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-planted-or-paved-roof-with-leaks-and-no-access-t"
  },
  {
   "grading": "check",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Leak history on a warm roof with no moisture survey",
   "impact": "3 Important",
   "timing": "Survey before choosing repair, recover or replace.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-leak-history-on-a-warm-roof-with-no-moisture-sur"
  },
  {
   "grading": "check",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Pre-1990s bitumen felts and mastics of unknown status",
   "impact": "3 Important",
   "timing": "Sample before cutting, coring or stripping.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-pre-1990s-bitumen-felts-and-mastics-of-unknown-s"
  },
  {
   "grading": "nil",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "finding": "Cosmetic wear to platform finishes",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/accessibility-lifts#f-cosmetic-wear-to-platform-finishes"
  },
  {
   "grading": "nil",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "finding": "Normal wear",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/air-handling-units#f-normal-wear"
  },
  {
   "grading": "nil",
   "page": "ancillary-structures",
   "element": "Ancillary Structures",
   "section": "External Elements",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/ancillary-structures#f-normal"
  },
  {
   "grading": "nil",
   "page": "architectural-and-decorative-features",
   "element": "Architectural & Decorative Features",
   "section": "Façades",
   "finding": "Surface soiling, minor erosion",
   "impact": "1 Routine",
   "timing": "Cleaning by appropriate method when warranted.",
   "url": "https://moyneross.com/technical/architectural-and-decorative-features#f-surface-soiling-minor-erosion"
  },
  {
   "grading": "nil",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "basement-cellars-and-retaining-walls",
   "element": "Basement, Cellars & Retaining Walls",
   "section": "Substructure",
   "finding": "Minor damp",
   "impact": "1 Routine",
   "timing": "Monitor.",
   "url": "https://moyneross.com/technical/basement-cellars-and-retaining-walls#f-minor-damp"
  },
  {
   "grading": "nil",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine resealing.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#f-normal"
  },
  {
   "grading": "nil",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "finding": "Minor wear in a maintained, certified system",
   "impact": "1 Routine",
   "timing": "Routine servicing.",
   "url": "https://moyneross.com/technical/building-maintenance-units#f-minor-wear-in-a-maintained-certified-system"
  },
  {
   "grading": "nil",
   "page": "building-management-and-control-system",
   "element": "Building Management & Control System (BMCS)",
   "section": "Mechanical Services",
   "finding": "Normal maintenance",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/building-management-and-control-system#f-normal-maintenance"
  },
  {
   "grading": "nil",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "finding": "Fabric wear, minor coating wear",
   "impact": "1 Routine",
   "timing": "Routine care.",
   "url": "https://moyneross.com/technical/canopies-and-awnings#f-fabric-wear-minor-coating-wear"
  },
  {
   "grading": "nil",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "finding": "Normal wear in a maintained plant",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/central-cooling-plant#f-normal-wear-in-a-maintained-plant"
  },
  {
   "grading": "nil",
   "page": "central-heating-plant",
   "element": "Central Heating Plant",
   "section": "Mechanical Services",
   "finding": "Normal wear",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/central-heating-plant#f-normal-wear"
  },
  {
   "grading": "nil",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "finding": "Minor weathering",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#f-minor-weathering"
  },
  {
   "grading": "nil",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "finding": "Isolated hairline cracks in render; minor coating wear",
   "impact": "1 Routine",
   "timing": "Routine care.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#f-isolated-hairline-cracks-in-render-minor-coating"
  },
  {
   "grading": "nil",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/commercial-kitchens#f-normal"
  },
  {
   "grading": "nil",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "finding": "Normal tenant wear within a lease",
   "impact": "1 Routine",
   "timing": "Recovered through make-good.",
   "url": "https://moyneross.com/technical/commercial-office-areas#f-normal-tenant-wear-within-a-lease"
  },
  {
   "grading": "nil",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/common-circulation-areas#f-normal"
  },
  {
   "grading": "nil",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/common-internal-areas#f-normal"
  },
  {
   "grading": "nil",
   "page": "communications-security-and-specialist-systems",
   "element": "Communications, Security & Specialist Systems",
   "section": "Electrical Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/communications-security-and-specialist-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/disabled-access#f-normal"
  },
  {
   "grading": "nil",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "finding": "Scuffing and cosmetic damage to dock doors and finishes",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#f-scuffing-and-cosmetic-damage-to-dock-doors-and-f"
  },
  {
   "grading": "nil",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "finding": "Minor dust",
   "impact": "1 Routine",
   "timing": "Routine cleaning.",
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#f-minor-dust"
  },
  {
   "grading": "nil",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "finding": "Working, metered, managed",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#f-working-metered-managed"
  },
  {
   "grading": "nil",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#f-normal"
  },
  {
   "grading": "nil",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "finding": "Isolated faults found and fixed at testing",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/emergency-lighting#f-isolated-faults-found-and-fixed-at-testing"
  },
  {
   "grading": "nil",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/emergency-power#f-normal"
  },
  {
   "grading": "nil",
   "page": "energy-efficiency-upgrades",
   "element": "Energy Efficiency Upgrades",
   "section": "Environmental",
   "finding": "Upgrades performing",
   "impact": "1 Routine",
   "timing": "Monitor.",
   "url": "https://moyneross.com/technical/energy-efficiency-upgrades#f-upgrades-performing"
  },
  {
   "grading": "nil",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "finding": "Cosmetic damage to balustrade panels and decking",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#f-cosmetic-damage-to-balustrade-panels-and-decking"
  },
  {
   "grading": "nil",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "finding": "Isolated scuffs, minor mould on shaded walls",
   "impact": "1 Routine",
   "timing": "Clean and touch up.",
   "url": "https://moyneross.com/technical/external-coating-systems#f-isolated-scuffs-minor-mould-on-shaded-walls"
  },
  {
   "grading": "nil",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#f-normal"
  },
  {
   "grading": "nil",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "finding": "Isolated faults found and fixed at service",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#f-isolated-faults-found-and-fixed-at-service"
  },
  {
   "grading": "nil",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/fire-pumping-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/fireplaces#f-normal"
  },
  {
   "grading": "nil",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/flooring#f-normal"
  },
  {
   "grading": "nil",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "finding": "Hairline cracks shown stable",
   "impact": "1 Routine",
   "timing": "Cosmetic repair.",
   "url": "https://moyneross.com/technical/foundations#f-hairline-cracks-shown-stable"
  },
  {
   "grading": "nil",
   "page": "gas-services",
   "element": "Gas Services",
   "section": "Hydraulic Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/gas-services#f-normal"
  },
  {
   "grading": "nil",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "finding": "Isolated misted unit; minor hardware wear",
   "impact": "1 Routine",
   "timing": "Replace or adjust in routine maintenance.",
   "url": "https://moyneross.com/technical/glazing-systems#f-isolated-misted-unit-minor-hardware-wear"
  },
  {
   "grading": "nil",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "finding": "Sound and managed materials",
   "impact": "1 Routine",
   "timing": "Manage in place.",
   "url": "https://moyneross.com/technical/hazardous-materials#f-sound-and-managed-materials"
  },
  {
   "grading": "nil",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "finding": "Normal wear",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/heat-rejection-plant#f-normal-wear"
  },
  {
   "grading": "nil",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#f-normal"
  },
  {
   "grading": "nil",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "finding": "Small gaps",
   "impact": "1 Routine",
   "timing": "Top up in routine maintenance.",
   "url": "https://moyneross.com/technical/insulation#f-small-gaps"
  },
  {
   "grading": "nil",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/integrated-building-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#f-normal"
  },
  {
   "grading": "nil",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/internal-stairwells#f-normal"
  },
  {
   "grading": "nil",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#f-normal"
  },
  {
   "grading": "nil",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/kitchen#f-normal"
  },
  {
   "grading": "nil",
   "page": "landscaping-and-irrigation",
   "element": "Landscaping & Irrigation",
   "section": "External Elements",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/landscaping-and-irrigation#f-normal"
  },
  {
   "grading": "nil",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#f-normal"
  },
  {
   "grading": "nil",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "finding": "Isolated failures",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/lighting#f-isolated-failures"
  },
  {
   "grading": "nil",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "finding": "Minor adjustments",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/lighting-control-system#f-minor-adjustments"
  },
  {
   "grading": "nil",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/lightning-protection#f-normal"
  },
  {
   "grading": "nil",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "finding": "Stable minor cracks",
   "impact": "1 Routine",
   "timing": "Monitor.",
   "url": "https://moyneross.com/technical/load-bearing-masonry#f-stable-minor-cracks"
  },
  {
   "grading": "nil",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#f-normal"
  },
  {
   "grading": "nil",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#f-normal"
  },
  {
   "grading": "nil",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "finding": "Normal wear",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/localised-hvac#f-normal-wear"
  },
  {
   "grading": "nil",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "finding": "Normal maintenance",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/main-electrical-supply#f-normal-maintenance"
  },
  {
   "grading": "nil",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#f-normal"
  },
  {
   "grading": "nil",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/maintenance-access-areas#f-normal"
  },
  {
   "grading": "nil",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "finding": "Hairline to 1 mm cracks of even width; historic movement shown stable; efflorescence on new work",
   "impact": "1 Routine",
   "timing": "Monitor; cosmetic repair once shown stable.",
   "url": "https://moyneross.com/technical/masonry-brickwork#f-hairline-to-1-mm-cracks-of-even-width-historic-m"
  },
  {
   "grading": "nil",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#f-normal"
  },
  {
   "grading": "nil",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/partitioning-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "finding": "Cosmetic wear to car interiors and fixtures",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#f-cosmetic-wear-to-car-interiors-and-fixtures"
  },
  {
   "grading": "nil",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "finding": "Minor door adjustments",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/passive-fire-protection#f-minor-door-adjustments"
  },
  {
   "grading": "nil",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "finding": "Minor wear",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/pavements-and-hardstand#f-minor-wear"
  },
  {
   "grading": "nil",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/plant-rooms#f-normal"
  },
  {
   "grading": "nil",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "finding": "Minor weathering",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#f-minor-weathering"
  },
  {
   "grading": "nil",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#f-normal"
  },
  {
   "grading": "nil",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "finding": "Minor defects",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/power-distribution#f-minor-defects"
  },
  {
   "grading": "nil",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/public-amenities#f-normal"
  },
  {
   "grading": "nil",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/pumping-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Debris in gutters, minor staining",
   "impact": "1 Routine",
   "timing": "Cleaning regime.",
   "url": "https://moyneross.com/technical/rainwater-systems#f-debris-in-gutters-minor-staining"
  },
  {
   "grading": "nil",
   "page": "recreational-facilities",
   "element": "Recreational Facilities",
   "section": "External Elements",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/recreational-facilities#f-normal"
  },
  {
   "grading": "nil",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#f-normal"
  },
  {
   "grading": "nil",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/retail-tenancies#f-normal"
  },
  {
   "grading": "nil",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "finding": "Chalking, minor lichen, swarf, algae streaks, a single cracked tile",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/roof-coverings#f-cosmetic"
  },
  {
   "grading": "nil",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "finding": "Minor wear, faded signage",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/roof-safety-systems#f-minor-wear-faded-signage"
  },
  {
   "grading": "nil",
   "page": "roof-structure",
   "element": "Roof Structure",
   "section": "Roofs & Rainwater Goods",
   "finding": "Truss uplift gaps; minor surface rust",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/roof-structure#f-truss-uplift-gaps-minor-surface-rust"
  },
  {
   "grading": "nil",
   "page": "sanitary-and-drainage-systems",
   "element": "Sanitary & Drainage Systems",
   "section": "Hydraulic Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/sanitary-and-drainage-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "finding": "Isolated failures at a few joints",
   "impact": "1 Routine",
   "timing": "Local repair in routine maintenance.",
   "url": "https://moyneross.com/technical/sealants-and-joints#f-isolated-failures-at-a-few-joints"
  },
  {
   "grading": "nil",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/service-corridors#f-normal"
  },
  {
   "grading": "nil",
   "page": "skylights-dormers-and-glazed-atria",
   "element": "Skylights, Dormers & Glazed Atria",
   "section": "Roofs & Rainwater Goods",
   "finding": "Minor discolouration",
   "impact": "1 Routine",
   "timing": "Clean.",
   "url": "https://moyneross.com/technical/skylights-dormers-and-glazed-atria#f-minor-discolouration"
  },
  {
   "grading": "nil",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "finding": "Fine shrinkage cracks",
   "impact": "1 Routine",
   "timing": "Seal where needed.",
   "url": "https://moyneross.com/technical/slab-on-ground#f-fine-shrinkage-cracks"
  },
  {
   "grading": "nil",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/smoke-management-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "solar-photovoltaic-systems",
   "element": "Solar Photovoltaic (PV) Systems",
   "section": "Electrical Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Clean and maintain.",
   "url": "https://moyneross.com/technical/solar-photovoltaic-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#f-normal"
  },
  {
   "grading": "nil",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#f-normal"
  },
  {
   "grading": "nil",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/specialist-hydraulics#f-normal"
  },
  {
   "grading": "nil",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "finding": "Minor faults found and fixed at service",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/specialist-suppression-systems#f-minor-faults-found-and-fixed-at-service"
  },
  {
   "grading": "nil",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/storage-and-archive-areas#f-normal"
  },
  {
   "grading": "nil",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine cleaning.",
   "url": "https://moyneross.com/technical/stormwater-drainage#f-normal"
  },
  {
   "grading": "nil",
   "page": "structural-core",
   "element": "Structural Core",
   "section": "Superstructure",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/structural-core#f-normal"
  },
  {
   "grading": "nil",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "finding": "Isolated minor cracking",
   "impact": "1 Routine",
   "timing": "Monitor.",
   "url": "https://moyneross.com/technical/structural-frame#f-isolated-minor-cracking"
  },
  {
   "grading": "nil",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine inspection.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#f-normal"
  },
  {
   "grading": "nil",
   "page": "sub-metering",
   "element": "Sub-metering",
   "section": "Environmental",
   "finding": "Accurate and reconciled",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/sub-metering#f-accurate-and-reconciled"
  },
  {
   "grading": "nil",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "finding": "Isolated faults",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/terminal-units#f-isolated-faults"
  },
  {
   "grading": "nil",
   "page": "trade-waste-systems",
   "element": "Trade Waste Systems",
   "section": "Hydraulic Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine pump-outs.",
   "url": "https://moyneross.com/technical/trade-waste-systems#f-normal"
  },
  {
   "grading": "nil",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "finding": "Minor shrinkage cracking",
   "impact": "1 Routine",
   "timing": "Monitor.",
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#f-minor-shrinkage-cracking"
  },
  {
   "grading": "nil",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "finding": "Normal wear",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/ventilation-systems#f-normal-wear"
  },
  {
   "grading": "nil",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "finding": "Cosmetic coating wear, isolated drummy tile",
   "impact": "1 Routine",
   "timing": "Routine care.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#f-cosmetic-coating-wear-isolated-drummy-tile"
  },
  {
   "grading": "nil",
   "page": "water-conservation",
   "element": "Water Conservation",
   "section": "Environmental",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Monitor.",
   "url": "https://moyneross.com/technical/water-conservation#f-normal"
  },
  {
   "grading": "nil",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "finding": "Normal",
   "impact": "1 Routine",
   "timing": "Routine.",
   "url": "https://moyneross.com/technical/water-supply#f-normal"
  },
  {
   "grading": "nil",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "finding": "Minor surface ageing, isolated dry blisters",
   "impact": "1 Routine",
   "timing": "Routine maintenance.",
   "url": "https://moyneross.com/technical/waterproofing-membranes#f-minor-surface-ageing-isolated-dry-blisters"
  }
 ]
}