 "rows": [
  {
   "market": "AU",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "id": "au-platform-lift-travel",
   "measure": "Travel limits by lift type",
   "threshold": "Low-rise platform lift: no more than 1000 mm; low-rise, low-speed constant pressure lift: no more than 2 m unenclosed or 4 m enclosed",
   "source": "NCC 2025 Volume One, Part E3 Lift installations",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations",
   "clause": "E3D7",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/accessibility-lifts#au-platform-lift-travel"
  },
  {
   "market": "AU",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "id": "au-sprinkler-trigger",
   "measure": "When sprinklers are required",
   "threshold": "Throughout a building where any part has an effective height of more than 25 m; new apartment buildings of four storeys and more since the 2019 amendments",
   "source": "NCC 2025 Volume One, Part E1 Fire fighting equipment",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment",
   "clause": "E1D5",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#au-sprinkler-trigger"
  },
  {
   "market": "AU",
   "page": "basement-cellars-and-retaining-walls",
   "element": "Basement, Cellars & Retaining Walls",
   "section": "Substructure",
   "id": "au-wall-cracks",
   "measure": "Wall crack categories (AS 2870)",
   "threshold": "Negligible under 0.1 mm; very slight under 1 mm; slight under 5 mm; moderate 5 to 15 mm; severe 15 to 25 mm",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/basement-cellars-and-retaining-walls#au-wall-cracks"
  },
  {
   "market": "AU",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "id": "au-hot-water-delivery",
   "measure": "Hot water at sanitary fixtures",
   "threshold": "No more than 45 °C in aged care, healthcare, early childhood centres and schools; 50 °C in most other buildings",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B2 Heated water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b2-heated-water-services",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#au-hot-water-delivery"
  },
  {
   "market": "AU",
   "page": "canopies-and-awnings",
   "element": "Canopies & Awnings",
   "section": "Façades",
   "id": "au-awning-inspection",
   "measure": "Awnings over public footways (New South Wales)",
   "threshold": "Awnings more than 10 years old inspected by a structural engineer",
   "source": "Planning Circular BS 13-001 Safety of awnings over public lands",
   "publisher": "NSW Department of Planning",
   "sourceUrl": "https://www.planning.nsw.gov.au/sites/default/files/2023-03/planning-circular-bs-13-001-safety-of-awnings-over-public-lands.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/canopies-and-awnings#au-awning-inspection"
  },
  {
   "market": "AU",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "id": "au-r22-supply",
   "measure": "R22 supply",
   "threshold": "From 1 January 2020, bulk R22 imports may only service existing equipment, within about 45 tonnes (45,000 kg) a year until 2029; from 1 January 2030 imports are banned and servicing relies on reclaimed refrigerant",
   "source": "R22 phase out fact sheet",
   "publisher": "Australian Government Department of Agriculture, Water and the Environment",
   "sourceUrl": "https://www.agriculture.gov.au/sites/default/files/documents/fs-r22-phase-out.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/central-cooling-plant#au-r22-supply"
  },
  {
   "market": "AU",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "id": "au-chimney-height",
   "measure": "Chimney or flue terminal height",
   "threshold": "At least 300 mm above any part of the building within 3.6 m horizontally",
   "source": "NCC 2025 Housing Provisions, Part 12.4 Heating appliances, fireplaces, chimneys and flues",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/12-ancillary-provisions/part-124-heating-appliances-fireplaces-chimneys-and-flues",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#au-chimney-height"
  },
  {
   "market": "AU",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "id": "au-hearth-extent",
   "measure": "Hearth extent, open fireplaces",
   "threshold": "At least 300 mm in front of the opening and 150 mm beyond each side",
   "source": "NCC 2025 Housing Provisions, Part 12.4 Heating appliances, fireplaces, chimneys and flues",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/12-ancillary-provisions/part-124-heating-appliances-fireplaces-chimneys-and-flues",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#au-hearth-extent"
  },
  {
   "market": "AU",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "id": "au-cladding-ground-clearance",
   "measure": "Cladding clearance to ground (houses)",
   "threshold": "150 mm to finished ground; 100 mm in low-rainfall or sandy, well-drained areas; 50 mm above paving that falls away; cladding taken 50 mm below the lowest floor framing",
   "source": "NCC 2025 Housing Provisions, Part 7.5 Timber and composite wall cladding",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/7-roof-and-wall-cladding/part-75-timber-and-composite-wall-cladding",
   "clause": "7.5.7",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#au-cladding-ground-clearance"
  },
  {
   "market": "AU",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "id": "au-travel-distance",
   "measure": "Travel distance, Class 5 to 9",
   "threshold": "No more than 20 m to an exit or point of choice, and no more than 40 m to one of two exits",
   "source": "NCC 2025 Volume One, Part D2 Provision for escape",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape",
   "clause": "D2D5",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/common-circulation-areas#au-travel-distance"
  },
  {
   "market": "AU",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "id": "au-apartment-entry-distance",
   "measure": "Apartment entry doors to an exit",
   "threshold": "Within 6 m of an exit or point of choice",
   "source": "NCC 2025 Volume One, Part D2 Provision for escape",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape",
   "clause": "D2D5",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/common-circulation-areas#au-apartment-entry-distance"
  },
  {
   "market": "AU",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "id": "au-fire-door-gaps",
   "measure": "Fire door gaps (AS 1905.1)",
   "threshold": "3 mm at the top and sides; no more than 10 mm at the bottom",
   "source": "Fire door intumescent seal regulations (quoting AS 1905.1 clearances)",
   "publisher": "LookUpStrata",
   "sourceUrl": "https://www.lookupstrata.com.au/q-a/nsw/fire-door-intumescent-seal-regulations",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/common-circulation-areas#au-fire-door-gaps"
  },
  {
   "market": "AU",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "id": "au-fire-door-gaps",
   "measure": "Fire door gaps (AS 1905.1)",
   "threshold": "3 mm at the top and sides; no more than 10 mm at the bottom",
   "source": "Fire door intumescent seal regulations (quoting AS 1905.1 clearances)",
   "publisher": "LookUpStrata",
   "sourceUrl": "https://www.lookupstrata.com.au/q-a/nsw/fire-door-intumescent-seal-regulations",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/common-internal-areas#au-fire-door-gaps"
  },
  {
   "market": "AU",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "id": "au-ev-boards",
   "measure": "EV charging readiness in car parks",
   "threshold": "Dedicated EV boards on each storey, sized for future 7 kW (32 A) chargers in 10 per cent of spaces (Class 5 and 6) or 20 per cent (Class 3, 7b, 8 and 9)",
   "source": "NCC 2025 Volume One, Part J9 Energy monitoring and on-site distributed energy resources",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources",
   "clause": "J9D4",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#au-ev-boards"
  },
  {
   "market": "AU",
   "page": "electric-vehicle-charging",
   "element": "Electric Vehicle (EV) Charging",
   "section": "Environmental",
   "id": "au-ev-din-rail",
   "measure": "Sub-metering space on EV boards",
   "threshold": "At least 36 mm of DIN rail per circuit",
   "source": "NCC 2025 Volume One, Part J9 Energy monitoring and on-site distributed energy resources",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources",
   "clause": "J9D4",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/electric-vehicle-charging#au-ev-din-rail"
  },
  {
   "market": "AU",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "id": "au-fire-door-gaps",
   "measure": "Fire door gaps (AS 1905.1)",
   "threshold": "3 mm at the top and sides; no more than 10 mm at the bottom",
   "source": "Fire door intumescent seal regulations (quoting AS 1905.1 clearances)",
   "publisher": "LookUpStrata",
   "sourceUrl": "https://www.lookupstrata.com.au/q-a/nsw/fire-door-intumescent-seal-regulations",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#au-fire-door-gaps"
  },
  {
   "market": "AU",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "id": "au-el-duration",
   "measure": "Rated duration",
   "threshold": "Typically 90 minutes",
   "source": "AS/NZS 2293.1:2026 Emergency lighting and exit signs for buildings, Part 1: System design, installation and operation",
   "publisher": "Standards Australia",
   "sourceUrl": "https://store.standards.org.au/product/as-nzs-2293-1-2026",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/emergency-lighting#au-el-duration"
  },
  {
   "market": "AU",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "id": "au-el-coverage",
   "measure": "Where emergency lighting is required",
   "threshold": "Every path of travel on a storey over 300 m²; rooms over 100 m² that do not open to a lit corridor or open space; rooms over 300 m²",
   "source": "NCC 2025 Volume One, Part E4 Visibility in an emergency, exit signs and warning systems",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems",
   "clause": "E4D2",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/emergency-lighting#au-el-coverage"
  },
  {
   "market": "AU",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "id": "au-pool-barrier",
   "measure": "Pool barriers (Queensland)",
   "threshold": "At least 1200 mm high; no more than 100 mm under the barrier; a 900 mm non-climbable zone; 300 mm clear inside",
   "source": "Pool fences: requirements for pool barriers",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://qbcc.qld.gov.au/home-owner-hub/swimming-pools/pool-safety-standard/pool-fences",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#au-pool-barrier"
  },
  {
   "market": "AU",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "id": "au-unit-entry-sound",
   "measure": "Alarm level at unit entry doors (Class 2 and 3)",
   "threshold": "85 dB(A) at the entry door with a smoke alarm system, or 100 dB(A) with a smoke detection system, in place of measuring inside the unit",
   "source": "NCC 2025 Volume One, Specification 20 Smoke detection and alarm systems",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#au-unit-entry-sound"
  },
  {
   "market": "AU",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "id": "au-boosted-hydrant-pressure",
   "measure": "Boosted hydrant pressure (New South Wales, AS 2419.1:2021)",
   "threshold": "700 kPa at the most hydraulically disadvantaged outlet in each pressure zone",
   "source": "Position statement summary: FRNSW pump performance for high rise buildings",
   "publisher": "Fire and Rescue NSW",
   "sourceUrl": "https://fire.nsw.gov.au/gallery/files/pdf/bfs/Position%20statement%20summary%20-%20FRNSW%20pump%20performance%20for%20high%20rise%20buildings.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/fire-pumping-systems#au-boosted-hydrant-pressure"
  },
  {
   "market": "AU",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "id": "au-hearth-extent",
   "measure": "Hearth extent, open fireplaces",
   "threshold": "At least 300 mm in front of the opening and 150 mm beyond each side",
   "source": "NCC 2025 Housing Provisions, Part 12.4 Heating appliances, fireplaces, chimneys and flues",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/12-ancillary-provisions/part-124-heating-appliances-fireplaces-chimneys-and-flues",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/fireplaces#au-hearth-extent"
  },
  {
   "market": "AU",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "id": "au-chimney-height",
   "measure": "Chimney or flue terminal height",
   "threshold": "At least 300 mm above any part of the building within 3.6 m horizontally",
   "source": "NCC 2025 Housing Provisions, Part 12.4 Heating appliances, fireplaces, chimneys and flues",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/12-ancillary-provisions/part-124-heating-appliances-fireplaces-chimneys-and-flues",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/fireplaces#au-chimney-height"
  },
  {
   "market": "AU",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "id": "au-wall-cracks",
   "measure": "Wall crack categories (AS 2870)",
   "threshold": "Negligible under 0.1 mm; very slight under 1 mm; slight under 5 mm; moderate 5 to 15 mm; severe 15 to 25 mm",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/foundations#au-wall-cracks"
  },
  {
   "market": "AU",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "id": "au-floor-offsets",
   "measure": "Floor offset from a 3 m straight edge (AS 2870)",
   "threshold": "Negligible under 8 mm; very slight under 10 mm; slight under 15 mm; moderate 15 to 25 mm; severe over 25 mm",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/foundations#au-floor-offsets"
  },
  {
   "market": "AU",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "id": "au-floor-slopes",
   "measure": "Floor slopes (AS 2870)",
   "threshold": "Local slopes steeper than 1 in 100 (10 mm per metre) are clearly visible; overall slopes beyond 1 in 150 (about 6.7 mm per metre) are undesirable",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/foundations#au-floor-slopes"
  },
  {
   "market": "AU",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "id": "au-side-panel-glass",
   "measure": "Side panels beside doorways (houses)",
   "threshold": "Framed side panels within 300 mm of a doorway: Grade A safety glass",
   "source": "NCC 2025 Housing Provisions, Part 8.4 Glazing: human impact",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/8-glazing/part-84-glazing-human-impact",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/glazing-systems#au-side-panel-glass"
  },
  {
   "market": "AU",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "id": "au-hot-water-delivery",
   "measure": "Hot water at sanitary fixtures",
   "threshold": "No more than 45 °C in aged care, healthcare patient areas, early childhood centres and schools; 50 °C in most other cases",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B2 Heated water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b2-heated-water-services",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#au-hot-water-delivery"
  },
  {
   "market": "AU",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "id": "au-relief-valve",
   "measure": "Storage heater relief",
   "threshold": "Rated working pressure, or 1400 kPa if lower, not exceeded; water kept below 99 °C",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B2 Heated water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b2-heated-water-services",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#au-relief-valve"
  },
  {
   "market": "AU",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "id": "au-boosted-hydrant-pressure",
   "measure": "Boosted hydrant pressure (AS 2419.1:2021, as applied in New South Wales)",
   "threshold": "700 kPa at the most disadvantaged outlet",
   "source": "Position statement summary: FRNSW pump performance for high rise buildings",
   "publisher": "Fire and Rescue NSW",
   "sourceUrl": "https://fire.nsw.gov.au/gallery/files/pdf/bfs/Position%20statement%20summary%20-%20FRNSW%20pump%20performance%20for%20high%20rise%20buildings.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#au-boosted-hydrant-pressure"
  },
  {
   "market": "AU",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "id": "au-feed-hydrant-residual",
   "measure": "Unassisted residual pressure at a feed hydrant flowing 10 L/s (AS 2419.1)",
   "threshold": "150 kPa in New South Wales; 200 kPa in the other states and territories",
   "source": "Fire and Rescue NSW fire hydrant testing 2017 (report MHL2534)",
   "publisher": "Fire and Rescue NSW",
   "sourceUrl": "https://www.fire.nsw.gov.au/gallery/files/pdf/bfs/MHL2534_Fire%20And%20Rescue%20Hydrant%20Testing.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#au-feed-hydrant-residual"
  },
  {
   "market": "AU",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "id": "au-hose-reel-coverage",
   "measure": "Hose reels",
   "threshold": "Within 4 m of an exit; a hose reel system serves any fire compartment over 500 m² without internal hydrants",
   "source": "NCC 2025 Volume One, Part E1 Fire fighting equipment",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#au-hose-reel-coverage"
  },
  {
   "market": "AU",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "id": "au-downlight-allowance",
   "measure": "Downlight clearances as lost insulation",
   "threshold": "About 20 downlights with 50 mm clearance, or 3 with 200 mm, use up 0.5 per cent of a 200 m² ceiling",
   "source": "NCC 2025 Housing Provisions, Part 13.2 Building fabric",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/13-energy-efficiency/part-132-building-fabric",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/insulation#au-downlight-allowance"
  },
  {
   "market": "AU",
   "page": "insulation",
   "element": "Insulation",
   "section": "Roofs & Rainwater Goods",
   "id": "au-insulation-laps",
   "measure": "Installed insulation",
   "threshold": "Bulk insulation kept at full thickness; reflective sheets lapped at least 150 mm or taped",
   "source": "NCC 2025 Housing Provisions, Part 13.2 Building fabric",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/13-energy-efficiency/part-132-building-fabric",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/insulation#au-insulation-laps"
  },
  {
   "market": "AU",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "id": "au-stair-door-force",
   "measure": "Stair pressurisation (AS 1668.1)",
   "threshold": "Door opening force at the handle no more than 110 N; air flowing through open stair doors at 1 m/s",
   "source": "Stair pressurisation performance in high-rise buildings (Fire, 2023, 6(4), 132)",
   "publisher": "MDPI",
   "sourceUrl": "https://www.mdpi.com/2571-6255/6/4/132",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/integrated-building-systems#au-stair-door-force"
  },
  {
   "market": "AU",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "id": "au-unit-entry-sound",
   "measure": "Alarm level at unit entry doors (Class 2 and 3)",
   "threshold": "85 dB(A) with a smoke alarm system, or 100 dB(A) with a smoke detection system",
   "source": "NCC 2025 Volume One, Specification 20 Smoke detection and alarm systems",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/integrated-building-systems#au-unit-entry-sound"
  },
  {
   "market": "AU",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "id": "au-fire-door-gaps",
   "measure": "Fire door gaps (AS 1905.1)",
   "threshold": "3 mm at the top and sides; no more than 10 mm at the bottom",
   "source": "Fire door intumescent seal regulations (quoting AS 1905.1 clearances)",
   "publisher": "LookUpStrata",
   "sourceUrl": "https://www.lookupstrata.com.au/q-a/nsw/fire-door-intumescent-seal-regulations",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#au-fire-door-gaps"
  },
  {
   "market": "AU",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "au-stair-risers-goings",
   "measure": "Risers and goings, public stairs",
   "threshold": "Risers 115 to 190 mm and goings 250 to 355 mm, constant through each flight; 2R + G between 550 and 700 mm; no more than 18 risers a flight",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": "D3D14",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/internal-stairwells#au-stair-risers-goings"
  },
  {
   "market": "AU",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "au-stair-handrails",
   "measure": "Handrails",
   "threshold": "On at least one side, and on both sides where the stair is 2 m wide or more; at least 865 mm above the nosings; continuous between landings",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": "D3D22",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/internal-stairwells#au-stair-handrails"
  },
  {
   "market": "AU",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "au-stair-barriers",
   "measure": "Barrier height",
   "threshold": "At least 865 mm above the nosings on a flight, and 1 m at landings and floors",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": "D3D17",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/internal-stairwells#au-stair-barriers"
  },
  {
   "market": "AU",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "au-stair-openings",
   "measure": "Openings between treads",
   "threshold": "Risers must not let a 125 mm sphere pass between treads",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": "D3D19",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/internal-stairwells#au-stair-openings"
  },
  {
   "market": "AU",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "au-fire-door-gaps",
   "measure": "Fire door gaps (AS 1905.1)",
   "threshold": "3 mm at the top and sides; no more than 10 mm at the bottom",
   "source": "Fire door intumescent seal regulations (quoting AS 1905.1 clearances)",
   "publisher": "LookUpStrata",
   "sourceUrl": "https://www.lookupstrata.com.au/q-a/nsw/fire-door-intumescent-seal-regulations",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-stairwells#au-fire-door-gaps"
  },
  {
   "market": "AU",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "id": "au-hot-water-delivery",
   "measure": "Hot water at sanitary fixtures",
   "threshold": "No more than 45 °C in aged care, healthcare, early childhood centres and schools; 50 °C in most other buildings",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B2 Heated water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b2-heated-water-services",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/kitchen#au-hot-water-delivery"
  },
  {
   "market": "AU",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "id": "au-control-zone",
   "measure": "Area per lighting control",
   "threshold": "No more than 250 m² of lighting per demand-operated control, other than in a single functional space",
   "source": "NCC 2025 Volume One, Part J7 Artificial lighting and power",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/lighting-control-system#au-control-zone"
  },
  {
   "market": "AU",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "id": "au-daylight-zone",
   "measure": "Daylight zone control",
   "threshold": "Separate control of the natural lighting zone in Class 5, 6 or 8 buildings over 250 m²",
   "source": "NCC 2025 Volume One, Part J7 Artificial lighting and power",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/lighting-control-system#au-daylight-zone"
  },
  {
   "market": "AU",
   "page": "lighting-control-system",
   "element": "Lighting Control System",
   "section": "Electrical Services",
   "id": "au-time-switch",
   "measure": "Time switches",
   "threshold": "Only where a space is regularly occupied: more than 1 person per 40 m², or used more than once every 15 minutes",
   "source": "NCC 2025 Volume One, Part J7 Artificial lighting and power",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/lighting-control-system#au-time-switch"
  },
  {
   "market": "AU",
   "page": "load-bearing-masonry",
   "element": "Load-Bearing Masonry",
   "section": "Superstructure",
   "id": "au-wall-cracks",
   "measure": "Wall crack categories (AS 2870)",
   "threshold": "Negligible under 0.1 mm; very slight under 1 mm; slight under 5 mm; moderate 5 to 15 mm; severe 15 to 25 mm; limits half as wide again for plasterboard partitions",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/load-bearing-masonry#au-wall-cracks"
  },
  {
   "market": "AU",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "id": "au-balustrade",
   "measure": "Barriers at upper levels",
   "threshold": "At least 1 m high where the floor is 1 m or more above the level below; openings that will not pass a 125 mm sphere",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/lobbies-and-atria#au-balustrade"
  },
  {
   "market": "AU",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "id": "au-crack-categories",
   "measure": "Masonry damage categories (AS 2870, Appendix C)",
   "threshold": "Category 0 under 0.1 mm; 1 under 1 mm; 2 under 5 mm; 3 from 5 to 15 mm; 4 from 15 to 25 mm",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/masonry-brickwork#au-crack-categories"
  },
  {
   "market": "AU",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "id": "au-stair-risers-goings",
   "measure": "Risers and goings, public stairs",
   "threshold": "Risers 115 to 190 mm; goings 250 to 355 mm",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": "D3D14",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/occupational-health-and-safety#au-stair-risers-goings"
  },
  {
   "market": "AU",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "id": "au-stretcher-lift",
   "measure": "Stretcher-sized lift",
   "threshold": "Where lifts serve storeys above an effective height of 12 m, at least one takes a raised stretcher in a space 600 mm by 2000 mm by 1400 mm high",
   "source": "NCC 2025 Volume One, Part E3 Lift installations",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations",
   "clause": "E3D3",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#au-stretcher-lift"
  },
  {
   "market": "AU",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "id": "au-fire-door-gaps",
   "measure": "Fire door gaps (AS 1905.1)",
   "threshold": "3 mm at the top and sides; no more than 10 mm at the bottom",
   "source": "Fire door intumescent seal regulations (quoting AS 1905.1 clearances)",
   "publisher": "LookUpStrata",
   "sourceUrl": "https://www.lookupstrata.com.au/q-a/nsw/fire-door-intumescent-seal-regulations",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/passive-fire-protection#au-fire-door-gaps"
  },
  {
   "market": "AU",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "id": "au-smoke-door-leaf",
   "measure": "Smoke door leaves",
   "threshold": "Solid-core leaves at least 35 mm thick, or leaves able to resist smoke at 200 °C for 30 minutes, with smoke seals",
   "source": "NCC 2025 Volume One, Specification 12 Fire doors, smoke doors, fire windows and shutters",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/c-fire-resistance/12-fire-doors-smoke-doors-fire-windows-and-shutters",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/passive-fire-protection#au-smoke-door-leaf"
  },
  {
   "market": "AU",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "id": "au-roof-edge-barrier",
   "measure": "Roof edge barrier",
   "threshold": "At least 1 m high where a roof with general access is 1 m or more above the surface below",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": "D3D17",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#au-roof-edge-barrier"
  },
  {
   "market": "AU",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "id": "au-apartment-extinguisher",
   "measure": "Extinguishers in apartment buildings",
   "threshold": "An ABE extinguisher of at least 2.5 kg within 10 m of each unit’s entry door",
   "source": "NCC 2025 Volume One, Part E1 Fire fighting equipment",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/portable-fire-equipment#au-apartment-extinguisher"
  },
  {
   "market": "AU",
   "page": "power-distribution",
   "element": "Power Distribution",
   "section": "Electrical Services",
   "id": "au-rcd-testing",
   "measure": "Fixed RCD testing (Victoria, after AS/NZS 3760)",
   "threshold": "Push-button test every 6 months; operating-time test every 12 months in high and medium risk areas, every 2 years in low risk areas",
   "source": "Electrical safety (inspection and testing timeframes)",
   "publisher": "WorkSafe Victoria",
   "sourceUrl": "https://www.worksafe.vic.gov.au/electrical-safety",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/power-distribution#au-rcd-testing"
  },
  {
   "market": "AU",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "id": "au-hot-water-delivery",
   "measure": "Hot water at sanitary fixtures",
   "threshold": "No more than 45 °C in aged care, healthcare, early childhood centres and schools; 50 °C in most other buildings",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B2 Heated water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b2-heated-water-services",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/public-amenities#au-hot-water-delivery"
  },
  {
   "market": "AU",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "id": "au-water-pressure",
   "measure": "Water pressure",
   "threshold": "Working pressure at least 50 kPa at outlets; static pressure no more than 500 kPa within the building",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B1 Cold water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b1-cold-water-services",
   "clause": "B1P6",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/pumping-systems#au-water-pressure"
  },
  {
   "market": "AU",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "au-design-storm",
   "measure": "Design storm",
   "threshold": "Eaves gutters: 5 per cent annual chance (1 in 20); box gutters: 1 per cent annual chance (1 in 100)",
   "source": "AS/NZS 3500.3:2025 Plumbing and drainage, Part 3: Stormwater drainage",
   "publisher": "Standards Australia",
   "sourceUrl": "https://store.standards.org.au/product/as-nzs-3500-3-2025",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/rainwater-systems#au-design-storm"
  },
  {
   "market": "AU",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "au-eaves-gutter-falls",
   "measure": "Eaves gutters on houses",
   "threshold": "Fall at least 1:500 unless designed to AS/NZS 3500.3; brackets at no more than 1.2 m centres",
   "source": "NCC 2025 Housing Provisions, Part 7.4 Gutters and downpipes",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/7-roof-and-wall-cladding/part-74-gutters-and-downpipes",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/rainwater-systems#au-eaves-gutter-falls"
  },
  {
   "market": "AU",
   "page": "rainwater-systems",
   "element": "Rainwater Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "au-eaves-gutter-overflow",
   "measure": "Eaves gutter overflow on houses, at 150 mm/h",
   "threshold": "0.17 L/s per metre of gutter for a 4 m ridge-to-gutter length; 0.25 L/s for 6 m; 0.33 L/s for 8 m",
   "source": "NCC 2025 Housing Provisions, Part 7.4 Gutters and downpipes",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/7-roof-and-wall-cladding/part-74-gutters-and-downpipes",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/rainwater-systems#au-eaves-gutter-overflow"
  },
  {
   "market": "AU",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "id": "au-unit-entry-sound",
   "measure": "Alarm level at unit entry doors (Class 2 and 3)",
   "threshold": "85 dB(A) with a smoke alarm system, or 100 dB(A) with a smoke detection system",
   "source": "NCC 2025 Volume One, Specification 20 Smoke detection and alarm systems",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#au-unit-entry-sound"
  },
  {
   "market": "AU",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "id": "au-hot-water-delivery",
   "measure": "Hot water at sanitary fixtures",
   "threshold": "No more than 45 °C in aged care, healthcare, early childhood centres and schools; 50 °C in most other buildings",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B2 Heated water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b2-heated-water-services",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#au-hot-water-delivery"
  },
  {
   "market": "AU",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "id": "au-sheet-end-laps",
   "measure": "Sheet roofing end laps",
   "threshold": "At least 150 mm above 15 degrees; 200 mm from 5 to 15 degrees",
   "source": "NCC 2025 Housing Provisions, Part 7.2 Sheet roofing",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/7-roof-and-wall-cladding/part-72-sheet-roofing",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/roof-coverings#au-sheet-end-laps"
  },
  {
   "market": "AU",
   "page": "roof-coverings",
   "element": "Roof Coverings",
   "section": "Roofs & Rainwater Goods",
   "id": "au-sarking",
   "measure": "Sarking under tiles",
   "threshold": "Laps at least 150 mm; fixed at no more than 300 mm centres; sags no deeper than 40 mm",
   "source": "NCC 2025 Housing Provisions, Part 7.3 Roof tiles and shingles",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/7-roof-and-wall-cladding/part-73-roof-tiles-and-shingles",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/roof-coverings#au-sarking"
  },
  {
   "market": "AU",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "au-roof-edge-barrier",
   "measure": "Roof edge barrier",
   "threshold": "At least 1 m high where a roof with general access is 1 m or more above the surface below",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": "D3D17",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/roof-safety-systems#au-roof-edge-barrier"
  },
  {
   "market": "AU",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "id": "au-travel-distance",
   "measure": "Travel distance, Class 5 to 9",
   "threshold": "No more than 20 m to an exit or point of choice, and no more than 40 m to one of two exits",
   "source": "NCC 2025 Volume One, Part D2 Provision for escape",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape",
   "clause": "D2D5",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/service-corridors#au-travel-distance"
  },
  {
   "market": "AU",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "id": "au-floor-offsets",
   "measure": "Floor offset from a 3 m straight edge (AS 2870)",
   "threshold": "Negligible under 8 mm; very slight under 10 mm; slight under 15 mm; moderate 15 to 25 mm; severe over 25 mm",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/slab-on-ground#au-floor-offsets"
  },
  {
   "market": "AU",
   "page": "slab-on-ground",
   "element": "Slab on Ground",
   "section": "Substructure",
   "id": "au-slab-cracks",
   "measure": "Crack width in house slabs (AS 2870)",
   "threshold": "Negligible under 0.3 mm; very slight under 1 mm; slight under 2 mm; moderate 2 to 4 mm; severe 4 to 10 mm",
   "source": "Standards and Tolerances Guide (December 2023), reproducing the AS 2870 damage categories",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://www.qbcc.qld.gov.au/sites/default/files/documents/guide-standards-tolerances.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/slab-on-ground#au-slab-cracks"
  },
  {
   "market": "AU",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "id": "au-stair-door-force",
   "measure": "Stair pressurisation (AS 1668.1)",
   "threshold": "Door opening force at the handle no more than 110 N; air flowing through open stair doors at 1 m/s",
   "source": "Stair pressurisation performance in high-rise buildings (Fire, 2023, 6(4), 132)",
   "publisher": "MDPI",
   "sourceUrl": "https://www.mdpi.com/2571-6255/6/4/132",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/smoke-management-systems#au-stair-door-force"
  },
  {
   "market": "AU",
   "page": "specialised-occupancy-areas",
   "element": "Specialised Occupancy Areas",
   "section": "Internal Areas",
   "id": "au-fume-cupboard",
   "measure": "Fume cupboard face velocity (AS/NZS 2243.8)",
   "threshold": "Average of 0.5 m/s, with no reading below 0.3 m/s; tested at least every 12 months",
   "source": "Local exhaust ventilation (LEV)",
   "publisher": "WorkSafe Queensland",
   "sourceUrl": "https://worksafe.qld.gov.au/safety-and-prevention/creating-safe-work/managing-risks/local-exhaust-ventilation-lev",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/specialised-occupancy-areas#au-fume-cupboard"
  },
  {
   "market": "AU",
   "page": "specialist-and-non-standard-features",
   "element": "Specialist & Non-Standard Features",
   "section": "Internal Areas",
   "id": "au-pool-barrier",
   "measure": "Pool barriers (Queensland)",
   "threshold": "At least 1200 mm high; no more than 100 mm under the barrier; a 900 mm non-climbable zone; 300 mm clear inside; boundary fences used as barriers at least 1800 mm",
   "source": "Pool fences: requirements for pool barriers",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://qbcc.qld.gov.au/home-owner-hub/swimming-pools/pool-safety-standard/pool-fences",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/specialist-and-non-standard-features#au-pool-barrier"
  },
  {
   "market": "AU",
   "page": "specialist-hydraulics",
   "element": "Specialist Hydraulics",
   "section": "Hydraulic Services",
   "id": "au-pool-barrier",
   "measure": "Pool barriers (Queensland)",
   "threshold": "At least 1200 mm high; no more than 100 mm under the barrier; a 900 mm non-climbable zone; 300 mm clear inside; boundary fences used as barriers at least 1800 mm",
   "source": "Pool fences: requirements for pool barriers",
   "publisher": "Queensland Building and Construction Commission",
   "sourceUrl": "https://qbcc.qld.gov.au/home-owner-hub/swimming-pools/pool-safety-standard/pool-fences",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/specialist-hydraulics#au-pool-barrier"
  },
  {
   "market": "AU",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "id": "au-subfloor-clearance",
   "measure": "Subfloor ground clearance",
   "threshold": "At least 150 mm under the lowest member; 400 mm where termite management relies on inspection",
   "source": "NCC 2025 Housing Provisions, Part 6.2 Subfloor ventilation",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/6-framing/part-62-subfloor-ventilation",
   "clause": "6.2.1",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#au-subfloor-clearance"
  },
  {
   "market": "AU",
   "page": "sub-floor-and-crawlspace",
   "element": "Sub-floor & Crawlspace",
   "section": "Substructure",
   "id": "au-subfloor-vents",
   "measure": "Subfloor ventilation openings",
   "threshold": "At least 2,000, 4,000 or 6,000 mm² per metre of wall in climate zones A, B and C; half where the ground is sealed with a membrane; 50 per cent more where excessively damp; spaced evenly, no more than 600 mm from corners",
   "source": "NCC 2025 Housing Provisions, Part 6.2 Subfloor ventilation",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/6-framing/part-62-subfloor-ventilation",
   "clause": "6.2.1",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/sub-floor-and-crawlspace#au-subfloor-vents"
  },
  {
   "market": "AU",
   "page": "sub-metering",
   "element": "Sub-metering",
   "section": "Environmental",
   "id": "au-energy-metering",
   "measure": "Energy metering",
   "threshold": "Over 500 m²: time-of-use metering of gas and electricity; over 2500 m²: separate meters for air conditioning, lighting, appliance power, central hot water and lifts",
   "source": "NCC 2025 Volume One, Part J9 Energy monitoring and on-site distributed energy resources",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources",
   "clause": "J9D3",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/sub-metering#au-energy-metering"
  },
  {
   "market": "AU",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "id": "au-fume-cupboard",
   "measure": "Fume cupboard face velocity (AS/NZS 2243.8)",
   "threshold": "Average of 0.5 m/s, with no reading below 0.3 m/s; tested at least every 12 months",
   "source": "Local exhaust ventilation (LEV): WorkSafe Queensland guidance",
   "publisher": "WorkSafe Queensland",
   "sourceUrl": "https://worksafe.qld.gov.au/safety-and-prevention/creating-safe-work/managing-risks/local-exhaust-ventilation-lev",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/ventilation-systems#au-fume-cupboard"
  },
  {
   "market": "AU",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "id": "au-balcony-barrier",
   "measure": "Barriers",
   "threshold": "Required where the surface is 1 m or more above the ground beneath; at least 1 m high; openings that will not pass a 125 mm sphere; above 4 m, no climbable horizontal elements between 150 mm and 760 mm",
   "source": "NCC 2025 Volume One, Part D3 Construction of exits",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits",
   "clause": null,
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#au-balcony-barrier"
  },
  {
   "market": "AU",
   "page": "water-supply",
   "element": "Water Supply",
   "section": "Hydraulic Services",
   "id": "au-water-pressure",
   "measure": "Water pressure",
   "threshold": "Working pressure at least 50 kPa at outlets; static pressure no more than 500 kPa within the building",
   "source": "NCC 2025 Volume Three (Plumbing Code), Part B1 Cold water services",
   "publisher": "Australian Building Codes Board",
   "sourceUrl": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-three/b-water-services/part-b1-cold-water-services",
   "clause": "B1P6",
   "basis": "primary",
   "note": "NCC 2025 value. NCC 2022 still governs in New South Wales, Queensland, South Australia, Tasmania and the Northern Territory until at least May 2027; check the edition in force where the asset is.",
   "url": "https://moyneross.com/technical/water-supply#au-water-pressure"
  },
  {
   "market": "AU",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "id": "au-membrane-fall",
   "measure": "Minimum fall, external membranes",
   "threshold": "1 in 100 (10 mm per metre)",
   "source": "AS 4654.2-2012 Waterproofing membranes for external above-ground use, Part 2: Design and installation",
   "publisher": "Standards Australia",
   "sourceUrl": "https://store.standards.org.au/product/as-4654-2-2012",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/waterproofing-membranes#au-membrane-fall"
  },
  {
   "market": "UK",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "id": "uk-lifting-platform-speed",
   "measure": "Lifting platform speed (England)",
   "threshold": "Rated speed no more than 0.15 m/s",
   "source": "Approved Document M, Volume 2: Buildings other than dwellings (with 2024 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/66f6c5eec71e42688b65ee11/ADM__V2_with_2024_amendments.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/accessibility-lifts#uk-lifting-platform-speed"
  },
  {
   "market": "UK",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "id": "uk-lift-examination",
   "measure": "Thorough examination (lifting equipment)",
   "threshold": "At least every 6 months for equipment that lifts people; every 12 months for other lifting equipment, unless an examination scheme sets otherwise",
   "source": "Thorough examination of lifting equipment (INDG422)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/indg422.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/accessibility-lifts#uk-lift-examination"
  },
  {
   "market": "UK",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "id": "uk-office-outside-air",
   "measure": "Outside air, offices (England)",
   "threshold": "10 L/s per person",
   "source": "Approved Document F, Volume 2: Buildings other than dwellings",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/62a761edd3bf7f03667c667e/ADF2_revised.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/air-handling-units#uk-office-outside-air"
  },
  {
   "market": "UK",
   "page": "air-handling-units",
   "element": "Air Handling Units (AHUs)",
   "section": "Mechanical Services",
   "id": "uk-office-co2",
   "measure": "Carbon dioxide in occupied spaces",
   "threshold": "Below 800 ppm suggests good ventilation; consistently above 1500 ppm calls for action",
   "source": "Approved Document F, Volume 2: Buildings other than dwellings",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/62a761edd3bf7f03667c667e/ADF2_revised.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/air-handling-units#uk-office-co2"
  },
  {
   "market": "UK",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "id": "uk-sprinkler-trigger",
   "measure": "When sprinklers are required (England)",
   "threshold": "New residential buildings with a storey more than 11 m above ground, since 2020",
   "source": "Approved Document B: Fire safety, volumes 1 and 2",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-approved-document-b",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#uk-sprinkler-trigger"
  },
  {
   "market": "UK",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "id": "uk-bathroom-extract",
   "measure": "Bathroom extract (England, dwellings)",
   "threshold": "At least 15 L/s run intermittently, or 8 L/s on a continuous system’s high rate",
   "source": "Approved Document F, Volume 1: Dwellings (2021 edition)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/61deba42d3bf7f054fcc243d/ADF1.pdf",
   "clause": "Table 1.1 and 1.2",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#uk-bathroom-extract"
  },
  {
   "market": "UK",
   "page": "bathrooms-and-wet-areas",
   "element": "Bathrooms & Wet Areas",
   "section": "Internal Areas",
   "id": "uk-hot-water-legionella",
   "measure": "Hot water temperatures (Legionella control)",
   "threshold": "Stored at 60 °C or more; 50 °C at outlets within one minute (55 °C in healthcare)",
   "source": "HSG274 Legionnaires’ disease: Technical guidance, Part 2: Hot and cold water systems",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg274part2.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/bathrooms-and-wet-areas#uk-hot-water-legionella"
  },
  {
   "market": "UK",
   "page": "chimney-stacks-and-flues",
   "element": "Chimney Stacks & Flues",
   "section": "Roofs & Rainwater Goods",
   "id": "uk-extract-grease",
   "measure": "Kitchen extract grease (TR19 Grease)",
   "threshold": "Deposits of no more than 200 microns; cleaning every 3, 6 or 12 months for heavy, moderate or light use",
   "source": "Ventilation hygiene standards (TR19)",
   "publisher": "Building Engineering Services Association",
   "sourceUrl": "https://www.thebesa.com/besa-blogs/ventilation-hygiene-standards",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/chimney-stacks-and-flues#uk-extract-grease"
  },
  {
   "market": "UK",
   "page": "cladding-and-wall-systems",
   "element": "Cladding & Wall Systems",
   "section": "Façades",
   "id": "uk-external-wall-class",
   "measure": "External wall surfaces, residential buildings (England)",
   "threshold": "Class A2-s1, d0 or better where a storey is more than 11 m above ground",
   "source": "Approved Document B, Volume 1: Dwellings (2026 online version)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/6aa3bb335f6e942efe37f150/AD_B1_2026.pdf",
   "clause": "Table 10.1",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/cladding-and-wall-systems#uk-external-wall-class"
  },
  {
   "market": "UK",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "id": "uk-hot-water-legionella",
   "measure": "Hot water temperatures (Legionella control)",
   "threshold": "Stored at 60 °C or more; 50 °C at outlets within one minute (55 °C in healthcare)",
   "source": "HSG274 Legionnaires’ disease: Technical guidance, Part 2: Hot and cold water systems",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg274part2.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/commercial-kitchens#uk-hot-water-legionella"
  },
  {
   "market": "UK",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "id": "uk-extract-grease",
   "measure": "Grease in kitchen extract ductwork (TR19 Grease)",
   "threshold": "Deposits of no more than 200 microns",
   "source": "Ventilation hygiene standards (TR19)",
   "publisher": "Building Engineering Services Association",
   "sourceUrl": "https://www.thebesa.com/besa-blogs/ventilation-hygiene-standards",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/commercial-kitchens#uk-extract-grease"
  },
  {
   "market": "UK",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "id": "uk-office-outside-air",
   "measure": "Outside air, offices (England)",
   "threshold": "10 L/s per person",
   "source": "Approved Document F, Volume 2: Buildings other than dwellings",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/62a761edd3bf7f03667c667e/ADF2_revised.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/commercial-office-areas#uk-office-outside-air"
  },
  {
   "market": "UK",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "id": "uk-office-co2",
   "measure": "Carbon dioxide in occupied spaces",
   "threshold": "Below 800 ppm suggests good ventilation; consistently above 1500 ppm calls for action",
   "source": "Approved Document F, Volume 2: Buildings other than dwellings",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/62a761edd3bf7f03667c667e/ADF2_revised.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/commercial-office-areas#uk-office-co2"
  },
  {
   "market": "UK",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "id": "uk-office-lighting",
   "measure": "Lighting at desks",
   "threshold": "Average 200 lux, with no point below 100 lux",
   "source": "Lighting at work (HSG38)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg38.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/commercial-office-areas#uk-office-lighting"
  },
  {
   "market": "UK",
   "page": "commercial-office-areas",
   "element": "Commercial Office Areas (Base-Build)",
   "section": "Internal Areas",
   "id": "uk-workroom-temperature",
   "measure": "Workroom temperature",
   "threshold": "Usually at least 16 °C",
   "source": "Temperature in the workplace: managing",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/temperature/employer/managing.htm",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/commercial-office-areas#uk-workroom-temperature"
  },
  {
   "market": "UK",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "id": "uk-fire-door-gaps",
   "measure": "Fire door gaps (England)",
   "threshold": "No more than 4 mm, except at the bottom",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/common-circulation-areas#uk-fire-door-gaps"
  },
  {
   "market": "UK",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "id": "uk-fire-door-checks",
   "measure": "Fire door checks (England, storey over 11 m)",
   "threshold": "Communal fire doors at least every 3 months; flat entrance doors every 12 months",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/common-circulation-areas#uk-fire-door-checks"
  },
  {
   "market": "UK",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "id": "uk-corridor-smoke-vent",
   "measure": "Corridor smoke vent free area (England)",
   "threshold": "At least 1.5 m² on an external wall, or 1 m² into a smoke shaft",
   "source": "Approved Document B, Volume 1: Dwellings (2026 online version)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/6aa3bb335f6e942efe37f150/AD_B1_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/common-circulation-areas#uk-corridor-smoke-vent"
  },
  {
   "market": "UK",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "id": "uk-fire-door-gaps",
   "measure": "Fire door gaps (England)",
   "threshold": "No more than 4 mm, except at the bottom",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/common-internal-areas#uk-fire-door-gaps"
  },
  {
   "market": "UK",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "id": "uk-fire-door-checks",
   "measure": "Fire door checks (England, storey over 11 m)",
   "threshold": "Communal fire doors at least every 3 months; flat entrance doors every 12 months",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/common-internal-areas#uk-fire-door-checks"
  },
  {
   "market": "UK",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "id": "uk-door-opening-force",
   "measure": "Opening force at the leading edge (England)",
   "threshold": "No more than 30 N from 0 to 30 degrees, and 22.5 N from 30 to 60 degrees",
   "source": "Approved Document M, Volume 2: Buildings other than dwellings (with 2024 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/66f6c5eec71e42688b65ee11/ADM__V2_with_2024_amendments.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/disabled-access#uk-door-opening-force"
  },
  {
   "market": "UK",
   "page": "dock-levellers-and-goods-hoists",
   "element": "Dock Levellers & Goods Hoists",
   "section": "Vertical Transportation",
   "id": "uk-lift-examination",
   "measure": "Thorough examination (lifting equipment)",
   "threshold": "At least every 6 months for equipment that lifts people; every 12 months for other lifting equipment, unless an examination scheme sets otherwise",
   "source": "Thorough examination of lifting equipment (INDG422)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/indg422.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/dock-levellers-and-goods-hoists#uk-lift-examination"
  },
  {
   "market": "UK",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "id": "uk-extract-grease",
   "measure": "Kitchen extract grease (TR19 Grease)",
   "threshold": "Deposits of no more than 200 microns",
   "source": "Ventilation hygiene standards (TR19)",
   "publisher": "Building Engineering Services Association",
   "sourceUrl": "https://www.thebesa.com/besa-blogs/ventilation-hygiene-standards",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#uk-extract-grease"
  },
  {
   "market": "UK",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "id": "uk-fire-door-gaps",
   "measure": "Fire door gaps (England)",
   "threshold": "No more than 4 mm, except at the bottom",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#uk-fire-door-gaps"
  },
  {
   "market": "UK",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "id": "uk-el-duration",
   "measure": "Rated duration",
   "threshold": "Designed for 1 to 3 hours, most often 3 hours where premises may be re-occupied straight after a failure",
   "source": "Fire safety risk assessment: offices and shops",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-risk-assessment-offices-and-shops",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/emergency-lighting#uk-el-duration"
  },
  {
   "market": "UK",
   "page": "emergency-power",
   "element": "Emergency Power",
   "section": "Electrical Services",
   "id": "uk-generator-run",
   "measure": "Routine generator runs",
   "threshold": "Standby diesel engines run for 30 minutes each week",
   "source": "Fire safety risk assessment: offices and shops",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-risk-assessment-offices-and-shops",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/emergency-power#uk-generator-run"
  },
  {
   "market": "UK",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "id": "uk-escalator-skirt-gap",
   "measure": "Step-to-skirt gap (BS EN 115)",
   "threshold": "No more than 4 mm on either side of a step; 7 mm in total across both sides",
   "source": "Innovative technologies that improve escalator passenger safety (Symposium on Lift and Escalator Technologies)",
   "publisher": "Rory S. Smith, University of Northampton",
   "sourceUrl": "https://liftescalatorlibrary.org/paper_indexing/papers/00000567.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#uk-escalator-skirt-gap"
  },
  {
   "market": "UK",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "id": "uk-escalator-speed",
   "measure": "Rated speed at a 30° incline (BS EN 115-1)",
   "threshold": "Up to 0.75 m/s",
   "source": "Innovative technologies that improve escalator passenger safety (Symposium on Lift and Escalator Technologies)",
   "publisher": "Rory S. Smith, University of Northampton",
   "sourceUrl": "https://liftescalatorlibrary.org/paper_indexing/papers/00000567.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#uk-escalator-speed"
  },
  {
   "market": "UK",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "id": "uk-bedhead-sound",
   "measure": "Alarm level in sleeping rooms",
   "threshold": "75 dB(A) at the bedhead",
   "source": "Fire safety risk assessment: sleeping accommodation",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-risk-assessment-sleeping-accommodation",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#uk-bedhead-sound"
  },
  {
   "market": "UK",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "id": "uk-separating-floor-sound",
   "measure": "Separating floors in flats (England)",
   "threshold": "New build: airborne at least 45 dB, impact no more than 62 dB; conversions: 43 dB and 64 dB",
   "source": "Approved Document E (2003 edition incorporating 2004, 2010, 2013 and 2015 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/5a809c4fe5274a2e87dbacb9/ADE_LOCKED.pdf",
   "clause": "Table 1.1",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/flooring#uk-separating-floor-sound"
  },
  {
   "market": "UK",
   "page": "foundations",
   "element": "Foundations",
   "section": "Substructure",
   "id": "uk-crack-categories",
   "measure": "Damage categories (BRE Digest 251)",
   "threshold": "Category 0 under 0.1 mm; 1 up to 1 mm; 2 up to 5 mm; 3 from 5 to 15 mm; 4 from 15 to 25 mm; 5 above 25 mm",
   "source": "BRE Digest 251 Assessment of damage in low-rise buildings (revised 1995)",
   "publisher": "BRE",
   "sourceUrl": "https://bregroup.com/store/bookshop/assessment-of-damage-in-low-rise-buildings-progressive-foundation-movement-revised-1995-dg-251",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/foundations#uk-crack-categories"
  },
  {
   "market": "UK",
   "page": "glazing-systems",
   "element": "Glazing Systems",
   "section": "Façades",
   "id": "uk-critical-locations",
   "measure": "Critical locations for glazing (England)",
   "threshold": "Below 800 mm in windows; up to 1500 mm in doors and in side panels within 300 mm of a door",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/glazing-systems#uk-critical-locations"
  },
  {
   "market": "UK",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "id": "uk-cooling-tower-counts",
   "measure": "Cooling tower general aerobic count",
   "threshold": "Under control up to 10,000 cfu/ml; corrective action above 100,000 cfu/ml",
   "source": "HSG274 Legionnaires’ disease: Technical guidance, Part 1: Evaporative cooling systems",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg274part1.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/heat-rejection-plant#uk-cooling-tower-counts"
  },
  {
   "market": "UK",
   "page": "heat-rejection-plant",
   "element": "Heat Rejection Plant",
   "section": "Mechanical Services",
   "id": "uk-cooling-tower-legionella",
   "measure": "Cooling tower Legionella",
   "threshold": "Review above 100 cfu/litre; immediate action above 1,000 cfu/litre",
   "source": "HSG274 Legionnaires’ disease: Technical guidance, Part 1: Evaporative cooling systems",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg274part1.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/heat-rejection-plant#uk-cooling-tower-legionella"
  },
  {
   "market": "UK",
   "page": "hot-and-warm-water-plant",
   "element": "Hot & Warm Water Plant",
   "section": "Hydraulic Services",
   "id": "uk-hot-water-legionella",
   "measure": "Hot water temperatures (Legionella control)",
   "threshold": "Stored at 60 °C or more; 50 °C at outlets within one minute (55 °C in healthcare); return to the calorifier no less than 50 °C",
   "source": "HSG274 Legionnaires’ disease: Technical guidance, Part 2: Hot and cold water systems",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg274part2.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/hot-and-warm-water-plant#uk-hot-water-legionella"
  },
  {
   "market": "UK",
   "page": "hydrant-and-hose-reel-systems",
   "element": "Hydrant & Hose Reel Systems",
   "section": "Fire Services",
   "id": "uk-dry-main-access",
   "measure": "Fire service access to dry main inlets (England)",
   "threshold": "A pumping appliance within 18 m of each inlet, with the inlet visible from where it parks",
   "source": "Approved Document B, Volume 2: Buildings other than dwellings (2026 online version)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/6aa3bb7492e72b8ac437f145/AD_B2_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/hydrant-and-hose-reel-systems#uk-dry-main-access"
  },
  {
   "market": "UK",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "id": "uk-bedhead-sound",
   "measure": "Alarm level in sleeping rooms",
   "threshold": "75 dB(A) at the bedhead",
   "source": "Fire safety risk assessment: sleeping accommodation",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-risk-assessment-sleeping-accommodation",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/integrated-building-systems#uk-bedhead-sound"
  },
  {
   "market": "UK",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "id": "uk-fire-door-gaps",
   "measure": "Fire door gaps (England)",
   "threshold": "No more than 4 mm, except at the bottom",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#uk-fire-door-gaps"
  },
  {
   "market": "UK",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "id": "uk-door-opening-force",
   "measure": "Opening force at the leading edge (England)",
   "threshold": "No more than 30 N from closed to 30° open, and 22.5 N from 30° to 60°",
   "source": "Approved Document M, Volume 2: Buildings other than dwellings (with 2024 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/66f6c5eec71e42688b65ee11/ADM__V2_with_2024_amendments.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#uk-door-opening-force"
  },
  {
   "market": "UK",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "uk-stair-rise-going",
   "measure": "Rise and going, general access stairs (England)",
   "threshold": "Rises 150 to 170 mm and goings 250 to 400 mm",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-stairwells#uk-stair-rise-going"
  },
  {
   "market": "UK",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "uk-stair-handrails",
   "measure": "Handrail height (England)",
   "threshold": "900 to 1000 mm above the pitch line",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-stairwells#uk-stair-handrails"
  },
  {
   "market": "UK",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "uk-fire-door-gaps",
   "measure": "Fire door gaps (England)",
   "threshold": "No more than 4 mm, except at the bottom",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-stairwells#uk-fire-door-gaps"
  },
  {
   "market": "UK",
   "page": "kitchen",
   "element": "Kitchen",
   "section": "Internal Areas",
   "id": "uk-kitchen-extract",
   "measure": "Kitchen extract (England, dwellings)",
   "threshold": "At least 30 L/s through a cooker hood ducted outside, 60 L/s from a fan elsewhere, or 13 L/s on a continuous system’s high rate",
   "source": "Approved Document F, Volume 1: Dwellings (2021 edition)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/61deba42d3bf7f054fcc243d/ADF1.pdf",
   "clause": "Table 1.1 and 1.2",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/kitchen#uk-kitchen-extract"
  },
  {
   "market": "UK",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "id": "uk-lift-car-size",
   "measure": "Passenger lift car size (England, new lifts)",
   "threshold": "At least 1100 mm wide and 1400 mm deep",
   "source": "Approved Document M, Volume 2: Buildings other than dwellings (with 2024 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/66f6c5eec71e42688b65ee11/ADM__V2_with_2024_amendments.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#uk-lift-car-size"
  },
  {
   "market": "UK",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "id": "uk-lift-examination",
   "measure": "Thorough examination of lifts",
   "threshold": "At least every 6 months for equipment that lifts people",
   "source": "Thorough examination of lifting equipment (INDG422)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/indg422.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#uk-lift-examination"
  },
  {
   "market": "UK",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "id": "uk-circulation-lighting",
   "measure": "Corridors and circulation routes",
   "threshold": "Average 20 lux, with no point below 5 lux",
   "source": "Lighting at work (HSG38)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg38.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lighting#uk-circulation-lighting"
  },
  {
   "market": "UK",
   "page": "lighting",
   "element": "Lighting",
   "section": "Electrical Services",
   "id": "uk-task-lighting",
   "measure": "Offices and fine work",
   "threshold": "Offices: average 200 lux, minimum 100 lux; fine work: average 500 lux, minimum 200 lux",
   "source": "Lighting at work (HSG38)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg38.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lighting#uk-task-lighting"
  },
  {
   "market": "UK",
   "page": "lightning-protection",
   "element": "Lightning Protection",
   "section": "Electrical Services",
   "id": "uk-rolling-sphere",
   "measure": "Rolling sphere radius by protection level (BS EN 62305)",
   "threshold": "20 m, 30 m, 45 m and 60 m for levels I to IV",
   "source": "BS EN 62305-1:2011 Protection against lightning: General principles",
   "publisher": "BSI",
   "sourceUrl": "https://knowledge.bsigroup.com/products/protection-against-lightning-general-principles-1",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lightning-protection#uk-rolling-sphere"
  },
  {
   "market": "UK",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "id": "uk-balustrade",
   "measure": "Guarding (England)",
   "threshold": "At least 1100 mm high; no openings that pass a 100 mm sphere",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lobbies-and-atria#uk-balustrade"
  },
  {
   "market": "UK",
   "page": "lobbies-and-atria",
   "element": "Lobbies & Atria",
   "section": "Internal Areas",
   "id": "uk-circulation-lighting",
   "measure": "Circulation routes",
   "threshold": "Average 20 lux, with no point below 5 lux",
   "source": "Lighting at work (HSG38)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg38.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lobbies-and-atria#uk-circulation-lighting"
  },
  {
   "market": "UK",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "id": "uk-door-opening-force",
   "measure": "Opening force at the leading edge (England)",
   "threshold": "No more than 30 N from 0 to 30 degrees, and 22.5 N from 30 to 60 degrees",
   "source": "Approved Document M, Volume 2: Buildings other than dwellings (with 2024 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/66f6c5eec71e42688b65ee11/ADM__V2_with_2024_amendments.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#uk-door-opening-force"
  },
  {
   "market": "UK",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "id": "uk-roof-edge-guarding",
   "measure": "Guarding at edges (England)",
   "threshold": "At least 1100 mm high",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/maintenance-access-areas#uk-roof-edge-guarding"
  },
  {
   "market": "UK",
   "page": "masonry-brickwork",
   "element": "Masonry/Brickwork",
   "section": "Façades",
   "id": "uk-crack-categories",
   "measure": "Damage categories (BRE Digest 251)",
   "threshold": "Category 0 under 0.1 mm; 1 up to 1 mm; 2 up to 5 mm; 3 from 5 to 15 mm; 4 from 15 to 25 mm; 5 above 25 mm",
   "source": "BRE Digest 251 Assessment of damage in low-rise buildings (revised 1995)",
   "publisher": "BRE",
   "sourceUrl": "https://bregroup.com/store/bookshop/assessment-of-damage-in-low-rise-buildings-progressive-foundation-movement-revised-1995-dg-251",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/masonry-brickwork#uk-crack-categories"
  },
  {
   "market": "UK",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "id": "uk-roof-edge-guarding",
   "measure": "Guarding at edges (England)",
   "threshold": "At least 1100 mm high",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/occupational-health-and-safety#uk-roof-edge-guarding"
  },
  {
   "market": "UK",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "id": "uk-separating-wall-sound",
   "measure": "Separating walls between dwellings (England)",
   "threshold": "Airborne sound insulation at least 45 dB for purpose-built flats and houses; 43 dB in conversions",
   "source": "Approved Document E (2003 edition incorporating 2004, 2010, 2013 and 2015 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/5a809c4fe5274a2e87dbacb9/ADE_LOCKED.pdf",
   "clause": "Table 1a",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/partitioning-systems#uk-separating-wall-sound"
  },
  {
   "market": "UK",
   "page": "partitioning-systems",
   "element": "Partitioning Systems",
   "section": "Internal Areas",
   "id": "uk-glazing-manifestation",
   "measure": "Manifestation on glazed screens and doors (England)",
   "threshold": "At two levels: 850 mm to 1000 mm and 1400 mm to 1600 mm; logos at least 150 mm high, or bands at least 50 mm high",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": "7.4",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/partitioning-systems#uk-glazing-manifestation"
  },
  {
   "market": "UK",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "id": "uk-lift-car-size",
   "measure": "Passenger lift car size (England, new lifts)",
   "threshold": "At least 1100 mm wide and 1400 mm deep",
   "source": "Approved Document M, Volume 2: Buildings other than dwellings (with 2024 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/66f6c5eec71e42688b65ee11/ADM__V2_with_2024_amendments.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#uk-lift-car-size"
  },
  {
   "market": "UK",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "id": "uk-lift-examination",
   "measure": "Thorough examination (lifting equipment)",
   "threshold": "At least every 6 months for equipment that lifts people; every 12 months for other lifting equipment, unless an examination scheme sets otherwise",
   "source": "Thorough examination of lifting equipment (INDG422)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/indg422.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#uk-lift-examination"
  },
  {
   "market": "UK",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "id": "uk-fire-door-gaps",
   "measure": "Fire door gaps (England)",
   "threshold": "No more than 4 mm, except at the bottom",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/passive-fire-protection#uk-fire-door-gaps"
  },
  {
   "market": "UK",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "id": "uk-fire-door-checks",
   "measure": "Fire door checks (England, storey over 11 m)",
   "threshold": "Communal fire doors at least every 3 months; flat entrance doors at least every 12 months",
   "source": "Fire Safety (England) Regulations 2022: fire door guidance",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-england-regulations-2022-fire-door-guidance/fire-safety-england-regulations-2022-fire-door-guidance",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/passive-fire-protection#uk-fire-door-checks"
  },
  {
   "market": "UK",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "id": "uk-roof-edge-guarding",
   "measure": "Roof edge guarding (England)",
   "threshold": "At least 1100 mm high",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#uk-roof-edge-guarding"
  },
  {
   "market": "UK",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "id": "uk-extinguisher-travel",
   "measure": "Travel distance to an extinguisher",
   "threshold": "No more than 30 m",
   "source": "Fire safety risk assessment: offices and shops",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-risk-assessment-offices-and-shops",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/portable-fire-equipment#uk-extinguisher-travel"
  },
  {
   "market": "UK",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "id": "uk-extinguisher-height",
   "measure": "Handle height",
   "threshold": "About 1 m for larger extinguishers and 1.5 m for smaller ones",
   "source": "Fire safety risk assessment: offices and shops",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-risk-assessment-offices-and-shops",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/portable-fire-equipment#uk-extinguisher-height"
  },
  {
   "market": "UK",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "id": "uk-hot-water-legionella",
   "measure": "Hot water temperatures (Legionella control)",
   "threshold": "Stored at 60 °C or more; 50 °C at outlets within one minute (55 °C in healthcare)",
   "source": "HSG274 Legionnaires’ disease: Technical guidance, Part 2: Hot and cold water systems",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg274part2.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/public-amenities#uk-hot-water-legionella"
  },
  {
   "market": "UK",
   "page": "public-amenities",
   "element": "Public Amenities",
   "section": "Internal Areas",
   "id": "uk-little-used-outlets",
   "measure": "Infrequently used outlets",
   "threshold": "Flushed at least every 7 days, or as the risk assessment sets",
   "source": "HSG274 Legionnaires’ disease: Technical guidance, Part 2: Hot and cold water systems",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg274part2.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/public-amenities#uk-little-used-outlets"
  },
  {
   "market": "UK",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "id": "uk-bedhead-sound",
   "measure": "Alarm level in sleeping rooms",
   "threshold": "75 dB(A) at the bedhead",
   "source": "Fire safety risk assessment: sleeping accommodation",
   "publisher": "UK Government",
   "sourceUrl": "https://www.gov.uk/government/publications/fire-safety-risk-assessment-sleeping-accommodation",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#uk-bedhead-sound"
  },
  {
   "market": "UK",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "id": "uk-bathroom-extract",
   "measure": "Bathroom extract (England, dwellings)",
   "threshold": "At least 15 L/s run intermittently, or 8 L/s on a continuous system’s high rate",
   "source": "Approved Document F, Volume 1: Dwellings (2021 edition)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/61deba42d3bf7f054fcc243d/ADF1.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#uk-bathroom-extract"
  },
  {
   "market": "UK",
   "page": "residential-units-guest-rooms",
   "element": "Residential Units/Guest Rooms",
   "section": "Internal Areas",
   "id": "uk-separating-floor-sound",
   "measure": "Separating floors in flats (England)",
   "threshold": "New build: airborne at least 45 dB, impact no more than 62 dB; conversions: 43 dB and 64 dB",
   "source": "Approved Document E (2003 edition incorporating 2004, 2010, 2013 and 2015 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/5a809c4fe5274a2e87dbacb9/ADE_LOCKED.pdf",
   "clause": "Table 1.1",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/residential-units-guest-rooms#uk-separating-floor-sound"
  },
  {
   "market": "UK",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "id": "uk-extract-grease",
   "measure": "Kitchen extract grease (TR19 Grease)",
   "threshold": "Deposits of no more than 200 microns",
   "source": "Ventilation hygiene standards (TR19)",
   "publisher": "Building Engineering Services Association",
   "sourceUrl": "https://www.thebesa.com/besa-blogs/ventilation-hygiene-standards",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/retail-tenancies#uk-extract-grease"
  },
  {
   "market": "UK",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "id": "uk-foul-drain-gradients",
   "measure": "Foul drain gradients (England)",
   "threshold": "100 mm drain serving at least one WC: 1:80 or steeper; 150 mm drain serving at least five: 1:150; 75 mm or 100 mm drains with peak flow below 1 L/s: 1:40",
   "source": "Approved Document H: Drainage and waste disposal (2015 edition)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/5a80cf9ded915d74e33fc8ae/BR_PDF_AD_H_2015.pdf",
   "clause": "Table 6",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/retail-tenancies#uk-foul-drain-gradients"
  },
  {
   "market": "UK",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "uk-roof-edge-guarding",
   "measure": "Roof edge guarding (England)",
   "threshold": "At least 1100 mm high",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/roof-safety-systems#uk-roof-edge-guarding"
  },
  {
   "market": "UK",
   "page": "sanitary-and-drainage-systems",
   "element": "Sanitary & Drainage Systems",
   "section": "Hydraulic Services",
   "id": "uk-foul-drain-gradients",
   "measure": "Foul drain gradients (England)",
   "threshold": "100 mm drain serving at least one WC: 1:80 or steeper; 150 mm drain serving at least five: 1:150; 75 mm or 100 mm drains with peak flow below 1 L/s: 1:40",
   "source": "Approved Document H: Drainage and waste disposal (2015 edition)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/5a80cf9ded915d74e33fc8ae/BR_PDF_AD_H_2015.pdf",
   "clause": "Table 6",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/sanitary-and-drainage-systems#uk-foul-drain-gradients"
  },
  {
   "market": "UK",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "id": "uk-circulation-lighting",
   "measure": "Corridors and circulation routes",
   "threshold": "Average 20 lux, with no point below 5 lux",
   "source": "Lighting at work (HSG38)",
   "publisher": "Health and Safety Executive",
   "sourceUrl": "https://www.hse.gov.uk/pubns/priced/hsg38.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/service-corridors#uk-circulation-lighting"
  },
  {
   "market": "UK",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "id": "uk-smoke-vent-area",
   "measure": "Smoke vents and shafts (England)",
   "threshold": "Corridor or lobby vent on an external wall: free area at least 1.5 m²; smoke shaft: section at least 1.5 m², with vents of at least 1 m²",
   "source": "Approved Document B, Volume 1: Dwellings (2026 online version)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/6aa3bb335f6e942efe37f150/AD_B1_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/smoke-management-systems#uk-smoke-vent-area"
  },
  {
   "market": "UK",
   "page": "smoke-management-systems",
   "element": "Smoke Management Systems",
   "section": "Fire Services",
   "id": "uk-smoke-shaft-outlet",
   "measure": "Smoke shaft outlet (England)",
   "threshold": "At least 0.5 m above surrounding structures within 2 m, and at least 2.5 m above the ceiling of the highest storey served",
   "source": "Approved Document B, Volume 1: Dwellings (2026 online version)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/6aa3bb335f6e942efe37f150/AD_B1_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/smoke-management-systems#uk-smoke-shaft-outlet"
  },
  {
   "market": "UK",
   "page": "stormwater-drainage",
   "element": "Stormwater Drainage",
   "section": "External Elements",
   "id": "uk-rainwater-drain-gradients",
   "measure": "Rainwater drain gradients (England)",
   "threshold": "75 mm and 100 mm drains no flatter than 1:100; 150 mm at 1:150; 225 mm at 1:225",
   "source": "Approved Document H: Drainage and waste disposal (2015 edition)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/5a80cf9ded915d74e33fc8ae/BR_PDF_AD_H_2015.pdf",
   "clause": "paragraph 3.15",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/stormwater-drainage#uk-rainwater-drain-gradients"
  },
  {
   "market": "UK",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "id": "uk-deflection-limits",
   "measure": "Deflection (Eurocode 2 and former British practice)",
   "threshold": "Sag beyond span/250 impairs appearance; after partitions, deflection may be limited to span/500; brittle finishes damaged at L/500 or 20 mm, whichever is less",
   "source": "Deflection and preliminary vibration effects on structural elements (The Structural Engineer, 89(5), 2011)",
   "publisher": "Denis Camilleri, The Structural Engineer",
   "sourceUrl": "https://www.dhiperiti.com/wp-content/uploads/2023/01/7.-Denis-Camilleri-Deflection-preliminary-vibration-effects-on-Structural-Elements-The-Structural-Engineer-89-5-1-March-2011.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/structural-frame#uk-deflection-limits"
  },
  {
   "market": "UK",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "id": "uk-office-outside-air",
   "measure": "Outside air, offices (England)",
   "threshold": "10 L/s per person",
   "source": "Approved Document F, Volume 2: Buildings other than dwellings",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/62a761edd3bf7f03667c667e/ADF2_revised.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/terminal-units#uk-office-outside-air"
  },
  {
   "market": "UK",
   "page": "terminal-units",
   "element": "Terminal Units",
   "section": "Mechanical Services",
   "id": "uk-office-co2",
   "measure": "Carbon dioxide in occupied spaces",
   "threshold": "Below 800 ppm suggests good ventilation; consistently above 1500 ppm calls for action",
   "source": "Approved Document F, Volume 2: Buildings other than dwellings",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/62a761edd3bf7f03667c667e/ADF2_revised.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/terminal-units#uk-office-co2"
  },
  {
   "market": "UK",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "id": "uk-deflection-limits",
   "measure": "Deflection (Eurocode 2 and former British practice)",
   "threshold": "Sag beyond span/250 impairs appearance; after partitions, deflection may be limited to span/500; brittle finishes damaged at L/500 or 20 mm, whichever is less",
   "source": "Deflection and preliminary vibration effects on structural elements (The Structural Engineer, 89(5), 2011)",
   "publisher": "Denis Camilleri, The Structural Engineer",
   "sourceUrl": "https://www.dhiperiti.com/wp-content/uploads/2023/01/7.-Denis-Camilleri-Deflection-preliminary-vibration-effects-on-Structural-Elements-The-Structural-Engineer-89-5-1-March-2011.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#uk-deflection-limits"
  },
  {
   "market": "UK",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "id": "uk-extract-grease",
   "measure": "Kitchen extract grease (TR19 Grease)",
   "threshold": "Deposits of no more than 200 microns",
   "source": "Ventilation hygiene standards (TR19)",
   "publisher": "Building Engineering Services Association",
   "sourceUrl": "https://www.thebesa.com/besa-blogs/ventilation-hygiene-standards",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/ventilation-systems#uk-extract-grease"
  },
  {
   "market": "UK",
   "page": "verandahs-balconies-and-balustrades",
   "element": "Verandahs, Balconies & Balustrades",
   "section": "Façades",
   "id": "uk-balcony-guarding",
   "measure": "Balcony guarding (England)",
   "threshold": "At least 1100 mm high; no openings that pass a 100 mm sphere",
   "source": "Approved Document K (2013 edition incorporating 2016 and 2020 amendments)",
   "publisher": "UK Government",
   "sourceUrl": "https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/verandahs-balconies-and-balustrades#uk-balcony-guarding"
  },
  {
   "market": "UK",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "id": "uk-membrane-fall",
   "measure": "Minimum finished fall, flat roofs",
   "threshold": "1 in 80 (12.5 mm per metre)",
   "source": "BS 6229:2025 Flat roofs with continuously supported flexible waterproof coverings",
   "publisher": "BSI",
   "sourceUrl": "https://knowledge.bsigroup.com/products/flat-roofs-with-continuously-supported-flexible-waterproof-coverings-code-of-practice-1",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/waterproofing-membranes#uk-membrane-fall"
  },
  {
   "market": "US",
   "page": "accessibility-lifts",
   "element": "Accessibility Lifts",
   "section": "Vertical Transportation",
   "id": "us-lift-levelling",
   "measure": "Levelling and sill gap",
   "threshold": "Within 13 mm (1/2 in) of the landing from rated load to no load; no more than 32 mm between car sill and landing",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "407.4",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/accessibility-lifts#us-lift-levelling"
  },
  {
   "market": "US",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "id": "us-storage-clearance",
   "measure": "Clearance below sprinkler deflectors",
   "threshold": "At least 457 mm (18 in) to the top of storage",
   "source": "29 CFR 1910.159 Automatic sprinkler systems",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-L/section-1910.159",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#us-storage-clearance"
  },
  {
   "market": "US",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "id": "us-main-drain-decline",
   "measure": "Main drain test decline",
   "threshold": "More than 10 per cent below the previous reading: evaluate immediately; more than 20 per cent: treat as an emergency",
   "source": "UFM 3-601-02 Fire protection systems inspection, testing, and maintenance (13 March 2026)",
   "publisher": "US Department of Defense",
   "sourceUrl": "https://www.wbdg.org/FFC/DOD/UFC/ufm_3_601_02_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#us-main-drain-decline"
  },
  {
   "market": "US",
   "page": "automatic-sprinkler-systems",
   "element": "Automatic Sprinkler Systems",
   "section": "Fire Services",
   "id": "us-sprinkler-test-intervals",
   "measure": "Test intervals",
   "threshold": "Main drain flow test every 12 months; inspector’s test valve opened at least every 2 years",
   "source": "29 CFR 1910.159 Automatic sprinkler systems",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-L/section-1910.159",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/automatic-sprinkler-systems#us-sprinkler-test-intervals"
  },
  {
   "market": "US",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "id": "us-bmu-inspection",
   "measure": "Inspection intervals (powered platforms)",
   "threshold": "Supporting building structure: at intervals not exceeding 12 months; equipment: at the manufacturer’s intervals, not exceeding 12 months",
   "source": "1910.66 Powered platforms for building maintenance",
   "publisher": "OSHA",
   "sourceUrl": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.66",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/building-maintenance-units#us-bmu-inspection"
  },
  {
   "market": "US",
   "page": "building-maintenance-units",
   "element": "Building Maintenance Units (BMU)",
   "section": "Façades",
   "id": "us-bmu-perimeter-guard",
   "measure": "Roof perimeter guard and davits",
   "threshold": "Guard no more than 152 mm (6 in) inboard of the parapet or curb; setback no more than 457 mm (18 in); davits over 36 kg moved with their centre of gravity at or below 914 mm",
   "source": "1910.66 Powered platforms for building maintenance",
   "publisher": "OSHA",
   "sourceUrl": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.66",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/building-maintenance-units#us-bmu-perimeter-guard"
  },
  {
   "market": "US",
   "page": "central-cooling-plant",
   "element": "Central Cooling Plant",
   "section": "Mechanical Services",
   "id": "us-refrigerant-leak",
   "measure": "Refrigerant leak repair trigger",
   "threshold": "Appliances holding 50 lb (about 23 kg) or more of ozone-depleting refrigerant: repair when leaking more than 10 per cent a year for comfort cooling, 20 per cent for commercial refrigeration, 30 per cent for industrial process refrigeration",
   "source": "40 CFR 82.157 Appliance maintenance and leak repair",
   "publisher": "US Environmental Protection Agency",
   "sourceUrl": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F/section-82.157",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/central-cooling-plant#us-refrigerant-leak"
  },
  {
   "market": "US",
   "page": "commercial-kitchens",
   "element": "Commercial Kitchens",
   "section": "Internal Areas",
   "id": "us-co-workplace",
   "measure": "Carbon monoxide, workplace exposure",
   "threshold": "50 ppm averaged over 8 hours",
   "source": "29 CFR 1910.1000 Air contaminants (Table Z-1)",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-Z/section-1910.1000",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/commercial-kitchens#us-co-workplace"
  },
  {
   "market": "US",
   "page": "common-circulation-areas",
   "element": "Common Circulation Areas",
   "section": "Internal Areas",
   "id": "us-fire-door-gaps",
   "measure": "Fire door gaps (NFPA 80)",
   "threshold": "About 3 mm (1/8 in) at the head and jambs; up to 19 mm (3/4 in) at the bottom",
   "source": "Measuring door gaps around and under fire doors",
   "publisher": "Firestop Contractors International Association",
   "sourceUrl": "https://www.fcia.org/Portals/0/180324%20Measuring%20Door%20Gaps.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/common-circulation-areas#us-fire-door-gaps"
  },
  {
   "market": "US",
   "page": "common-internal-areas",
   "element": "Common Internal Areas",
   "section": "Internal Areas",
   "id": "us-fire-door-gaps",
   "measure": "Fire door gaps (NFPA 80)",
   "threshold": "About 3 mm (1/8 in) at the head and jambs; up to 19 mm (3/4 in) at the bottom",
   "source": "Measuring door gaps around and under fire doors",
   "publisher": "Firestop Contractors International Association",
   "sourceUrl": "https://www.fcia.org/Portals/0/180324%20Measuring%20Door%20Gaps.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/common-internal-areas#us-fire-door-gaps"
  },
  {
   "market": "US",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "id": "us-door-clear-width",
   "measure": "Door clear width",
   "threshold": "At least 815 mm with the door open 90 degrees",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "404.2.3",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/disabled-access#us-door-clear-width"
  },
  {
   "market": "US",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "id": "us-door-opening-force",
   "measure": "Opening force, interior doors",
   "threshold": "No more than 22.2 N",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "404.2.9",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/disabled-access#us-door-opening-force"
  },
  {
   "market": "US",
   "page": "disabled-access",
   "element": "Disabled Access (DDA)",
   "section": "Building Code Compliance",
   "id": "us-ramp-level-change",
   "measure": "Ramps and changes in level",
   "threshold": "Ramps no steeper than 1:12; level changes up to 6.4 mm vertical, 6.4 to 13 mm bevelled no steeper than 1:2",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "303 and 405",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/disabled-access#us-ramp-level-change"
  },
  {
   "market": "US",
   "page": "ductwork-and-air-distribution",
   "element": "Ductwork & Air Distribution",
   "section": "Mechanical Services",
   "id": "us-damper-testing",
   "measure": "Fire and smoke damper testing",
   "threshold": "One year after construction, then every 6 years",
   "source": "UFM 3-601-02 Fire protection systems inspection, testing, and maintenance (13 March 2026)",
   "publisher": "US Department of Defense",
   "sourceUrl": "https://www.wbdg.org/FFC/DOD/UFC/ufm_3_601_02_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/ductwork-and-air-distribution#us-damper-testing"
  },
  {
   "market": "US",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "id": "us-fire-door-gaps",
   "measure": "Fire door gaps (NFPA 80)",
   "threshold": "About 3 mm (1/8 in) at the head and jambs; up to 19 mm (3/4 in) at the bottom",
   "source": "Measuring door gaps around and under fire doors",
   "publisher": "Firestop Contractors International Association",
   "sourceUrl": "https://www.fcia.org/Portals/0/180324%20Measuring%20Door%20Gaps.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#us-fire-door-gaps"
  },
  {
   "market": "US",
   "page": "electrical-and-communications-risers",
   "element": "Electrical & Communications Risers",
   "section": "Internal Areas",
   "id": "us-electrical-working-space",
   "measure": "Working space in front of electrical equipment",
   "threshold": "At least 0.9 m deep and 762 mm wide (or the width of the equipment), with 1.98 m of headroom, for equipment up to 150 V to ground",
   "source": "29 CFR 1910.303 Electrical: General",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-S/section-1910.303",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/electrical-and-communications-risers#us-electrical-working-space"
  },
  {
   "market": "US",
   "page": "emergency-lighting",
   "element": "Emergency Lighting",
   "section": "Electrical Services",
   "id": "us-el-test",
   "measure": "Full-duration test",
   "threshold": "Battery units run for at least 90 minutes each year",
   "source": "UFM 3-601-02 Fire protection systems inspection, testing, and maintenance (13 March 2026)",
   "publisher": "US Department of Defense",
   "sourceUrl": "https://www.wbdg.org/FFC/DOD/UFC/ufm_3_601_02_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/emergency-lighting#us-el-test"
  },
  {
   "market": "US",
   "page": "escalators-and-moving-walks",
   "element": "Escalators & Moving Walks",
   "section": "Vertical Transportation",
   "id": "us-escalator-speed",
   "measure": "Rated speed at a 30° incline (ASME A17.1)",
   "threshold": "Up to 0.5 m/s",
   "source": "Innovative technologies that improve escalator passenger safety (Symposium on Lift and Escalator Technologies)",
   "publisher": "Rory S. Smith, University of Northampton",
   "sourceUrl": "https://liftescalatorlibrary.org/paper_indexing/papers/00000567.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/escalators-and-moving-walks#us-escalator-speed"
  },
  {
   "market": "US",
   "page": "external-coating-systems",
   "element": "External Coating Systems",
   "section": "Façades",
   "id": "us-lead-paint",
   "measure": "Lead-based paint",
   "threshold": "Lead at or above 1.0 mg/cm² by XRF, or 0.5 per cent by weight in a laboratory sample",
   "source": "24 CFR 35.86 Definitions (lead-based paint)",
   "publisher": "US Department of Housing and Urban Development",
   "sourceUrl": "https://www.gpo.gov/fdsys/pkg/CFR-2013-title24-vol1/pdf/CFR-2013-title24-vol1-sec35-86.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/external-coating-systems#us-lead-paint"
  },
  {
   "market": "US",
   "page": "fencing-gates-and-signage",
   "element": "Fencing, Gates & Signage",
   "section": "External Elements",
   "id": "us-gate-width-force",
   "measure": "Doors and gates on accessible routes",
   "threshold": "At least 815 mm clear; no more than 22.2 N to open (interior)",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "404",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/fencing-gates-and-signage#us-gate-width-force"
  },
  {
   "market": "US",
   "page": "fire-detection-and-alarm-systems",
   "element": "Fire Detection & Alarm Systems",
   "section": "Fire Services",
   "id": "us-public-mode-sound",
   "measure": "Alarm level, public mode",
   "threshold": "At least 15 dB above the average ambient level; 75 dB(A) at the pillow in sleeping rooms",
   "source": "Audibility vs. intelligibility of fire alarm systems (FPE Extra, issue 69)",
   "publisher": "Society of Fire Protection Engineers",
   "sourceUrl": "https://sfpe.connectedcommunity.org/publications/fpemagazine/fpeextra/etarchives3/fpeetissue69",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/fire-detection-and-alarm-systems#us-public-mode-sound"
  },
  {
   "market": "US",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "id": "us-pump-run-times",
   "measure": "Weekly pump run",
   "threshold": "Electric pumps 10 minutes; engine-driven pumps 30 minutes",
   "source": "UFM 3-601-02 Fire protection systems inspection, testing, and maintenance (13 March 2026)",
   "publisher": "US Department of Defense",
   "sourceUrl": "https://www.wbdg.org/FFC/DOD/UFC/ufm_3_601_02_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/fire-pumping-systems#us-pump-run-times"
  },
  {
   "market": "US",
   "page": "fire-pumping-systems",
   "element": "Fire Pumping Systems",
   "section": "Fire Services",
   "id": "us-flow-test-decline",
   "measure": "Flow test decline",
   "threshold": "More than 10 per cent below the previous or acceptance reading: evaluate immediately; more than 20 per cent: emergency",
   "source": "UFM 3-601-02 Fire protection systems inspection, testing, and maintenance (13 March 2026)",
   "publisher": "US Department of Defense",
   "sourceUrl": "https://www.wbdg.org/FFC/DOD/UFC/ufm_3_601_02_2026.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/fire-pumping-systems#us-flow-test-decline"
  },
  {
   "market": "US",
   "page": "fireplaces",
   "element": "Fireplaces",
   "section": "Internal Areas",
   "id": "us-co-workplace",
   "measure": "Carbon monoxide, workplace exposure",
   "threshold": "50 ppm averaged over 8 hours",
   "source": "29 CFR 1910.1000 Air contaminants (Table Z-1)",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-Z/section-1910.1000",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/fireplaces#us-co-workplace"
  },
  {
   "market": "US",
   "page": "flooring",
   "element": "Flooring",
   "section": "Internal Areas",
   "id": "us-level-change",
   "measure": "Changes in level",
   "threshold": "Up to 6.4 mm may be vertical; 6.4 to 13 mm bevelled no steeper than 1:2",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "303",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/flooring#us-level-change"
  },
  {
   "market": "US",
   "page": "hazardous-materials",
   "element": "Hazardous Materials",
   "section": "Building Code Compliance",
   "id": "us-lead-paint",
   "measure": "Lead-based paint",
   "threshold": "Lead at or above 1.0 mg/cm², or 0.5 per cent by weight",
   "source": "24 CFR 35.86 Definitions (lead-based paint)",
   "publisher": "US Department of Housing and Urban Development",
   "sourceUrl": "https://www.gpo.gov/fdsys/pkg/CFR-2013-title24-vol1/pdf/CFR-2013-title24-vol1-sec35-86.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/hazardous-materials#us-lead-paint"
  },
  {
   "market": "US",
   "page": "integrated-building-systems",
   "element": "Integrated Building Systems",
   "section": "Internal Areas",
   "id": "us-public-mode-sound",
   "measure": "Alarm level, public mode",
   "threshold": "At least 15 dB above the average ambient level",
   "source": "Audibility vs. intelligibility of fire alarm systems (FPE Extra, issue 69)",
   "publisher": "Society of Fire Protection Engineers",
   "sourceUrl": "https://sfpe.connectedcommunity.org/publications/fpemagazine/fpeextra/etarchives3/fpeetissue69",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/integrated-building-systems#us-public-mode-sound"
  },
  {
   "market": "US",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "id": "us-fire-door-gaps",
   "measure": "Fire door gaps (NFPA 80)",
   "threshold": "About 3 mm (1/8 in) at the head and jambs; up to 19 mm (3/4 in) at the bottom",
   "source": "Measuring door gaps around and under fire doors",
   "publisher": "Firestop Contractors International Association",
   "sourceUrl": "https://www.fcia.org/Portals/0/180324%20Measuring%20Door%20Gaps.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#us-fire-door-gaps"
  },
  {
   "market": "US",
   "page": "internal-doors-and-hardware",
   "element": "Internal Doors & Hardware",
   "section": "Internal Areas",
   "id": "us-door-opening-force",
   "measure": "Opening force, interior hinged doors",
   "threshold": "No more than 22.2 N (5 lbf); fire doors excepted",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "404.2.9",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-doors-and-hardware#us-door-opening-force"
  },
  {
   "market": "US",
   "page": "internal-stairwells",
   "element": "Internal Stairwells",
   "section": "Internal Areas",
   "id": "us-fire-door-gaps",
   "measure": "Fire door gaps (NFPA 80)",
   "threshold": "About 3 mm (1/8 in) at the head and jambs; up to 19 mm (3/4 in) at the bottom",
   "source": "Measuring door gaps around and under fire doors",
   "publisher": "Firestop Contractors International Association",
   "sourceUrl": "https://www.fcia.org/Portals/0/180324%20Measuring%20Door%20Gaps.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-stairwells#us-fire-door-gaps"
  },
  {
   "market": "US",
   "page": "internal-wall-and-ceiling-finishes",
   "element": "Internal Wall & Ceiling Finishes",
   "section": "Internal Areas",
   "id": "us-lead-paint",
   "measure": "Lead-based paint",
   "threshold": "Lead at or above 1.0 mg/cm² by XRF, or 0.5 per cent by weight in a laboratory sample",
   "source": "24 CFR 35.86 Definitions (lead-based paint)",
   "publisher": "US Department of Housing and Urban Development",
   "sourceUrl": "https://www.gpo.gov/fdsys/pkg/CFR-2013-title24-vol1/pdf/CFR-2013-title24-vol1-sec35-86.pdf",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/internal-wall-and-ceiling-finishes#us-lead-paint"
  },
  {
   "market": "US",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "id": "us-lift-levelling",
   "measure": "Levelling and sill gap",
   "threshold": "Within 13 mm from rated load to no load; no more than 32 mm between car sill and landing",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "407.4",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#us-lift-levelling"
  },
  {
   "market": "US",
   "page": "lift-cars-and-machine-rooms",
   "element": "Lift Cars & Machine Rooms",
   "section": "Internal Areas",
   "id": "us-lift-car-lighting",
   "measure": "Car lighting",
   "threshold": "At least 54 lux at the car controls, platform and threshold",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "407.4.5",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/lift-cars-and-machine-rooms#us-lift-car-lighting"
  },
  {
   "market": "US",
   "page": "loading-docks-and-goods-handling",
   "element": "Loading Docks & Goods Handling",
   "section": "Internal Areas",
   "id": "us-co-workplace",
   "measure": "Carbon monoxide, workplace exposure",
   "threshold": "50 ppm averaged over 8 hours",
   "source": "29 CFR 1910.1000 Air contaminants (Table Z-1)",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-Z/section-1910.1000",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/loading-docks-and-goods-handling#us-co-workplace"
  },
  {
   "market": "US",
   "page": "localised-hvac",
   "element": "Localised HVAC",
   "section": "Mechanical Services",
   "id": "us-refrigerant-leak",
   "measure": "Refrigerant leak repair trigger",
   "threshold": "Appliances holding 50 lb (about 23 kg) or more of ozone-depleting refrigerant: repair when leaking more than 10 per cent a year for comfort cooling, 20 per cent for commercial refrigeration, 30 per cent for industrial process refrigeration",
   "source": "40 CFR 82.157 Appliance maintenance and leak repair",
   "publisher": "US Environmental Protection Agency",
   "sourceUrl": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F/section-82.157",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/localised-hvac#us-refrigerant-leak"
  },
  {
   "market": "US",
   "page": "main-electrical-supply",
   "element": "Main Electrical Supply",
   "section": "Electrical Services",
   "id": "us-electrical-working-space",
   "measure": "Working space in front of electrical equipment",
   "threshold": "At least 762 mm (30 in) wide and, at the lowest voltage class, 0.9 m (3 ft) deep",
   "source": "29 CFR 1910.303 Electrical: General",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-S/section-1910.303",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/main-electrical-supply#us-electrical-working-space"
  },
  {
   "market": "US",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "id": "us-door-opening-force",
   "measure": "Opening force, interior doors",
   "threshold": "No more than 22.2 N",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "404.2.9",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#us-door-opening-force"
  },
  {
   "market": "US",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "id": "us-door-clear-width",
   "measure": "Door clear width",
   "threshold": "At least 815 mm with the door open 90 degrees",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "404.2.3",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#us-door-clear-width"
  },
  {
   "market": "US",
   "page": "main-entrance-and-reception-areas",
   "element": "Main Entrance & Reception Areas",
   "section": "Internal Areas",
   "id": "us-level-change",
   "measure": "Changes in level",
   "threshold": "Up to 6.4 mm may be vertical; 6.4 to 13 mm bevelled no steeper than 1:2",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "303",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/main-entrance-and-reception-areas#us-level-change"
  },
  {
   "market": "US",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "id": "us-fixed-ladder-rungs",
   "measure": "Fixed ladder rungs",
   "threshold": "25 to 36 cm (10 to 14 in) apart; at least 41 cm (16 in) wide",
   "source": "29 CFR 1910.23 Ladders",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-D/section-1910.23",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/maintenance-access-areas#us-fixed-ladder-rungs"
  },
  {
   "market": "US",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "id": "us-guardrail",
   "measure": "Guardrails (workplaces)",
   "threshold": "1070 mm (42 in) high, plus or minus 75 mm",
   "source": "29 CFR 1910.29 Fall protection systems and falling object protection criteria",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-D/section-1910.29",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/maintenance-access-areas#us-guardrail"
  },
  {
   "market": "US",
   "page": "maintenance-access-areas",
   "element": "Maintenance Access Areas",
   "section": "Internal Areas",
   "id": "us-h2s",
   "measure": "Hydrogen sulfide, workplace exposure",
   "threshold": "Ceiling of 20 ppm; a single peak of 50 ppm for no more than 10 minutes",
   "source": "29 CFR 1910.1000 Air contaminants (Table Z-1)",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-Z/section-1910.1000",
   "clause": "Table Z-2",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/maintenance-access-areas#us-h2s"
  },
  {
   "market": "US",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "id": "us-guardrail",
   "measure": "Guardrails (workplaces)",
   "threshold": "1070 mm (42 in) high, plus or minus 75 mm",
   "source": "29 CFR 1910.29 Fall protection systems and falling object protection criteria",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-D/section-1910.29",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/occupational-health-and-safety#us-guardrail"
  },
  {
   "market": "US",
   "page": "occupational-health-and-safety",
   "element": "Occupational Health & Safety (OHS)",
   "section": "Building Code Compliance",
   "id": "us-fixed-ladder-rungs",
   "measure": "Fixed ladder rungs",
   "threshold": "25 to 36 cm (10 to 14 in) apart; at least 41 cm (16 in) wide",
   "source": "29 CFR 1910.23 Ladders",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-D/section-1910.23",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/occupational-health-and-safety#us-fixed-ladder-rungs"
  },
  {
   "market": "US",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "id": "us-lift-levelling",
   "measure": "Levelling and sill gap",
   "threshold": "Within 13 mm (1/2 in) of the landing from rated load to no load; no more than 32 mm between car sill and landing",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "407.4",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#us-lift-levelling"
  },
  {
   "market": "US",
   "page": "passenger-and-goods-lifts",
   "element": "Passenger & Goods Lifts",
   "section": "Vertical Transportation",
   "id": "us-lift-car-lighting",
   "measure": "Car lighting",
   "threshold": "At least 54 lux at the car controls, platform and threshold",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "407.4.5",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/passenger-and-goods-lifts#us-lift-car-lighting"
  },
  {
   "market": "US",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "id": "us-fire-door-gaps",
   "measure": "Fire door gaps (NFPA 80)",
   "threshold": "About 3 mm (1/8 in) at the head and jambs; up to 19 mm (3/4 in) at the bottom",
   "source": "Measuring door gaps around and under fire doors",
   "publisher": "Firestop Contractors International Association",
   "sourceUrl": "https://www.fcia.org/Portals/0/180324%20Measuring%20Door%20Gaps.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/passive-fire-protection#us-fire-door-gaps"
  },
  {
   "market": "US",
   "page": "passive-fire-protection",
   "element": "Passive Fire Protection",
   "section": "Fire Services",
   "id": "us-fire-door-inspection",
   "measure": "Fire door inspection (NFPA 80)",
   "threshold": "Every 12 months",
   "source": "Measuring door gaps around and under fire doors",
   "publisher": "Firestop Contractors International Association",
   "sourceUrl": "https://www.fcia.org/Portals/0/180324%20Measuring%20Door%20Gaps.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/passive-fire-protection#us-fire-door-inspection"
  },
  {
   "market": "US",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "id": "us-level-change",
   "measure": "Changes in level",
   "threshold": "Up to 6.4 mm may be vertical; 6.4 to 13 mm bevelled no steeper than 1:2; higher changes are treated as a ramp or step",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "303",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/pavements-and-hardstand#us-level-change"
  },
  {
   "market": "US",
   "page": "pavements-and-hardstand",
   "element": "Pavements & Hardstand",
   "section": "External Elements",
   "id": "us-parking-width",
   "measure": "Accessible car spaces",
   "threshold": "At least 2440 mm wide, with an adjacent access aisle",
   "source": "2010 ADA Standards for Accessible Design",
   "publisher": "US Department of Justice",
   "sourceUrl": "https://www.ada.gov/law-and-regs/design-standards/2010-stds/",
   "clause": "502",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/pavements-and-hardstand#us-parking-width"
  },
  {
   "market": "US",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "id": "us-refrigerant-leak",
   "measure": "Refrigerant leak repair trigger",
   "threshold": "Comfort cooling appliances with 50 lb (about 23 kg) or more of ozone-depleting refrigerant: repair when leaking more than 10 per cent a year",
   "source": "40 CFR 82.157 Appliance maintenance and leak repair",
   "publisher": "US Environmental Protection Agency",
   "sourceUrl": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F/section-82.157",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/plant-rooms#us-refrigerant-leak"
  },
  {
   "market": "US",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "id": "us-electrical-working-space",
   "measure": "Working space in front of electrical equipment",
   "threshold": "At least 762 mm (30 in) wide and, at the lowest voltage class, 0.9 m (3 ft) deep",
   "source": "29 CFR 1910.303 Electrical: General",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-S/section-1910.303",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/plant-rooms#us-electrical-working-space"
  },
  {
   "market": "US",
   "page": "plant-rooms",
   "element": "Plant Rooms",
   "section": "Internal Areas",
   "id": "us-fixed-ladder-rungs",
   "measure": "Fixed ladder rungs",
   "threshold": "25 to 36 cm (10 to 14 in) apart; at least 41 cm (16 in) wide",
   "source": "29 CFR 1910.23 Ladders",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-D/section-1910.23",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/plant-rooms#us-fixed-ladder-rungs"
  },
  {
   "market": "US",
   "page": "plant-screens-and-parapets",
   "element": "Plant Screens & Parapets",
   "section": "Roofs & Rainwater Goods",
   "id": "us-guardrail",
   "measure": "Guardrails (workplaces)",
   "threshold": "1070 mm (42 in) high, plus or minus 75 mm; resisting 890 N",
   "source": "29 CFR 1910.29 Fall protection systems and falling object protection criteria",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-D/section-1910.29",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/plant-screens-and-parapets#us-guardrail"
  },
  {
   "market": "US",
   "page": "portable-fire-equipment",
   "element": "Portable Fire Equipment",
   "section": "Fire Services",
   "id": "us-extinguisher-travel",
   "measure": "Travel distance to an extinguisher (workplaces)",
   "threshold": "22.9 m for Class A hazards; 15.2 m for Class B",
   "source": "29 CFR 1910.157 Portable fire extinguishers",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-L/section-1910.157",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/portable-fire-equipment#us-extinguisher-travel"
  },
  {
   "market": "US",
   "page": "pumping-systems",
   "element": "Pumping Systems",
   "section": "Hydraulic Services",
   "id": "us-h2s",
   "measure": "Hydrogen sulfide, workplace exposure",
   "threshold": "Ceiling of 20 ppm; a single peak of 50 ppm for no more than 10 minutes",
   "source": "29 CFR 1910.1000 Air contaminants (Table Z-1)",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-Z/section-1910.1000",
   "clause": "Table Z-2",
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/pumping-systems#us-h2s"
  },
  {
   "market": "US",
   "page": "retail-tenancies",
   "element": "Retail Tenancies (Base-Build)",
   "section": "Internal Areas",
   "id": "us-storage-clearance",
   "measure": "Clearance below sprinkler deflectors",
   "threshold": "At least 457 mm (18 in) to the top of storage",
   "source": "29 CFR 1910.159 Automatic sprinkler systems",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-L/section-1910.159",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/retail-tenancies#us-storage-clearance"
  },
  {
   "market": "US",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "us-guardrail",
   "measure": "Guardrails (workplaces)",
   "threshold": "1070 mm (42 in) high, plus or minus 75 mm; resisting 890 N",
   "source": "29 CFR 1910.29 Fall protection systems and falling object protection criteria",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-D/section-1910.29",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/roof-safety-systems#us-guardrail"
  },
  {
   "market": "US",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "us-fall-arrest",
   "measure": "Personal fall arrest (workplaces)",
   "threshold": "Free fall no more than 1.8 m; deceleration distance no more than 1.1 m; arresting force no more than 8 kN; anchorage holding 22.2 kN per person attached",
   "source": "29 CFR 1910.140 Personal fall protection systems",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-I/section-1910.140",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/roof-safety-systems#us-fall-arrest"
  },
  {
   "market": "US",
   "page": "roof-safety-systems",
   "element": "Roof Safety Systems",
   "section": "Roofs & Rainwater Goods",
   "id": "us-fixed-ladder-height",
   "measure": "Fixed ladders needing fall protection",
   "threshold": "Over 7.3 m (24 ft): a ladder safety or personal fall arrest system",
   "source": "Walking-working surfaces and fall protection",
   "publisher": "Occupational Safety and Health Administration",
   "sourceUrl": "https://www.osha.gov/walking-working-surfaces",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/roof-safety-systems#us-fixed-ladder-height"
  },
  {
   "market": "US",
   "page": "sealants-and-joints",
   "element": "Sealants & Joints",
   "section": "Façades",
   "id": "us-pcb-caulk",
   "measure": "PCBs in caulk",
   "threshold": "Caulk installed between 1950 and 1979 can contain as much as 40 per cent PCBs",
   "source": "Polychlorinated biphenyls (PCBs) in building materials",
   "publisher": "US Environmental Protection Agency",
   "sourceUrl": "https://www.epa.gov/pcbs/polychlorinated-biphenyls-pcbs-building-materials",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/sealants-and-joints#us-pcb-caulk"
  },
  {
   "market": "US",
   "page": "service-corridors",
   "element": "Service Corridors",
   "section": "Internal Areas",
   "id": "us-storage-clearance",
   "measure": "Clearance below sprinkler deflectors",
   "threshold": "At least 457 mm (18 in) to the top of storage",
   "source": "29 CFR 1910.159 Automatic sprinkler systems",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-L/section-1910.159",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/service-corridors#us-storage-clearance"
  },
  {
   "market": "US",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "id": "us-clean-agent-hold",
   "measure": "Clean agent hold time (NFPA 2001)",
   "threshold": "At least 10 minutes, or long enough for trained personnel to respond; end of hold commonly taken at 80 per cent of the minimum design concentration",
   "source": "Clean agent enclosure design (FPE Extra, issue 74)",
   "publisher": "Society of Fire Protection Engineers",
   "sourceUrl": "https://sfpe.connectedcommunity.org/publications/fpemagazine/fpeextra/etarchives3/fpeetissue74",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/specialist-suppression-systems#us-clean-agent-hold"
  },
  {
   "market": "US",
   "page": "specialist-suppression-systems",
   "element": "Specialist Suppression Systems",
   "section": "Fire Services",
   "id": "us-halocarbon-discharge",
   "measure": "Halocarbon discharge time (NFPA 2001)",
   "threshold": "About 10 seconds",
   "source": "Leakage rates and hold times for clean agent fire suppression enclosures",
   "publisher": "National Institute of Standards and Technology",
   "sourceUrl": "https://www.nist.gov/system/files/documents/el/fire_research/R0601297.pdf",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/specialist-suppression-systems#us-halocarbon-discharge"
  },
  {
   "market": "US",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "id": "us-imposed-loads",
   "measure": "Floor imposed loads (IBC Table 1607.1, as adopted in Massachusetts)",
   "threshold": "Offices 50 psf (2.4 kPa); light storage 125 psf (6.0 kPa)",
   "source": "780 CMR Table 1607.1 Minimum uniformly distributed live loads (Massachusetts State Building Code, adopting the IBC table)",
   "publisher": "Commonwealth of Massachusetts (via Justia Regulations)",
   "sourceUrl": "https://regulations.justia.com/states/massachusetts/780-cmr/chapter-16/section-1607/subsection-1607-1",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/storage-and-archive-areas#us-imposed-loads"
  },
  {
   "market": "US",
   "page": "storage-and-archive-areas",
   "element": "Storage & Archive Areas",
   "section": "Internal Areas",
   "id": "us-storage-clearance",
   "measure": "Clearance below sprinkler deflectors",
   "threshold": "At least 457 mm (18 in) to the top of storage",
   "source": "29 CFR 1910.159 Automatic sprinkler systems",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-L/section-1910.159",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/storage-and-archive-areas#us-storage-clearance"
  },
  {
   "market": "US",
   "page": "structural-frame",
   "element": "Structural Frame",
   "section": "Superstructure",
   "id": "us-imposed-loads",
   "measure": "Floor imposed loads (IBC Table 1607.1, as adopted in Massachusetts)",
   "threshold": "Offices 50 psf (2.4 kPa); corridors above the first floor 80 psf (3.8 kPa); light storage 125 psf (6.0 kPa)",
   "source": "780 CMR Table 1607.1 Minimum uniformly distributed live loads (Massachusetts State Building Code, adopting the IBC table)",
   "publisher": "Commonwealth of Massachusetts (via Justia Regulations)",
   "sourceUrl": "https://regulations.justia.com/states/massachusetts/780-cmr/chapter-16/section-1607/subsection-1607-1",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/structural-frame#us-imposed-loads"
  },
  {
   "market": "US",
   "page": "upper-floor-slabs-and-structures",
   "element": "Upper Floor Slabs & Structures",
   "section": "Superstructure",
   "id": "us-imposed-loads",
   "measure": "Floor imposed loads (IBC Table 1607.1, as adopted in Massachusetts)",
   "threshold": "Offices 50 psf (2.4 kPa); corridors above the first floor 80 psf (3.8 kPa); light storage 125 psf (6.0 kPa)",
   "source": "780 CMR Table 1607.1 Minimum uniformly distributed live loads (Massachusetts State Building Code, adopting the IBC table)",
   "publisher": "Commonwealth of Massachusetts (via Justia Regulations)",
   "sourceUrl": "https://regulations.justia.com/states/massachusetts/780-cmr/chapter-16/section-1607/subsection-1607-1",
   "clause": null,
   "basis": "secondary",
   "note": null,
   "url": "https://moyneross.com/technical/upper-floor-slabs-and-structures#us-imposed-loads"
  },
  {
   "market": "US",
   "page": "ventilation-systems",
   "element": "Ventilation Systems",
   "section": "Mechanical Services",
   "id": "us-co-workplace",
   "measure": "Carbon monoxide, workplace exposure",
   "threshold": "50 ppm averaged over 8 hours",
   "source": "29 CFR 1910.1000 Air contaminants (Table Z-1)",
   "publisher": "US Occupational Safety and Health Administration",
   "sourceUrl": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-Z/section-1910.1000",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/ventilation-systems#us-co-workplace"
  },
  {
   "market": "US",
   "page": "waterproofing-membranes",
   "element": "Waterproofing Membranes",
   "section": "Roofs & Rainwater Goods",
   "id": "us-membrane-fall",
   "measure": "Minimum slope, most membranes",
   "threshold": "About a quarter inch per foot (about 21 mm per metre, roughly 1 in 50)",
   "source": "2024 International Building Code",
   "publisher": "International Code Council",
   "sourceUrl": "https://codes.iccsafe.org/content/IBC2024P1",
   "clause": null,
   "basis": "primary",
   "note": null,
   "url": "https://moyneross.com/technical/waterproofing-membranes#us-membrane-fall"
  }
 ]
}