Every sign of failure the Technical Library records under External Elements: 48 signs across 6 elements and spaces. Each row gives what you see, the likely cause and what confirms it, and the next step. Each heading opens the page the rows come from.
Scope
A sign usually has more than one possible cause. Each row names the likely one and what would confirm it; none is a diagnosis of a particular building, and none is a price.
What you see Likely cause, and what confirms it Next step Pergola or carport leaning Post base decay or impact damage. Probe or inspect at ground level.Exclude people if it stands over a used area; replace the decayed posts on stirrups or with steel. Shade sail masts bent after a storm Wind overload; sail not removed. Inspection; design wind rating.Take the sail down; upgrade the masts and footings to an engineered design, and set take-down procedures. Rust bleeding from a flagpole or sign base Corrosion at the base and possible fatigue. Inspection; non-destructive testing of welds.Inspect the base and welds; repair or replace a corroded base, and replace a pole with fatigue cracking. Bin store, shed or carport roof sheets lifting Fixings inadequate for wind. Fixing type and spacing; corrosion.Refix the sheets with suitable fixings, and check the frame.
What you see Likely cause, and what confirms it Next step Cracked cement sheeting on an old shed Weathered asbestos cement. Sampling.Sample it; plan licensed removal, or encapsulate it where it is sound and undisturbed. Algae and slime in a water feature Inadequate treatment. Water testing.Test the water; treat it, or decommission the feature.
What you see Likely cause, and what confirms it Next step Structure with no record of approval Informal addition. Council or authority records.Check council or authority records; obtain retrospective approval or remove the structure. Structure close to a boundary or another building, built of combustible materials Possible fire spread. Distance to boundaries and buildings; materials.Check against fire separation rules, and relocate or line the structure if required.
What you see Likely cause, and what confirms it Next step Powered gate does not reverse when it meets an obstruction Force limitation or safety edge failure. Force measurement; device test.Disable the gate now; restore force limitation and safety edges, and test them. Gate jerks, jumps or leaves the track Worn rollers, track or stops. Inspection.Replace worn rollers, track or stops before the gate derails. Pool gate stays open from some positions Hinge tension or latch fault. Test from several open positions, and measure the barrier against the asset’s market (Thresholds by market ).Close the pool until fixed; adjust the hinge tension or replace the latch, and retest from every position. Pedestrian gate on an accessible route too narrow or heavy to open Access barrier. Clear width and opening force against the asset’s market (Thresholds by market ).Widen the gate, adjust the closer, or fit a powered operator.
What you see Likely cause, and what confirms it Next step Fence leaning in sections Post base decay. Probe posts.Replace the posts on galvanised stirrups or with steel. Boundary wall leaning with a tree nearby Root pressure or foundation movement. Inspection; engineer.Have an engineer assess it; repair or rebuild it with the neighbour's agreement.
What you see Likely cause, and what confirms it Next step Exit signs pointing to a removed door Layout changed without updating signs. Walkthrough against plans.Walk the routes against the plans and update the signs. Safety signs faded, missing or inconsistent Signs no longer effective. Signage audit against the site’s hazards.Replace with signs to the relevant standard.
What you see Likely cause, and what confirms it Next step Cracks in a building near a large tree on clay Subsidence from root moisture uptake. See foundations page.Assess the foundations before acting on the tree; on clay, removing it can cause heave. Repeated drain blockages near trees Root intrusion. CCTV.Survey by CCTV, clear and repair the drain, and fit a root barrier. Dead branches in a tree crown Decline, decay or root damage. Arborist assessment.Get an arborist's assessment and act on it; exclude people below if the tree is over an occupied area. Tree works planned near a building or new construction Root damage or removal affecting the tree or the building. Tree protection zone set by an arborist.Fence the protection zone before works start.
What you see Likely cause, and what confirms it Next step Leaks in a car park under a planter Membrane failure or blocked drainage. Flood test; drainage inspection.Flood test the planter and clear its drainage; replace the membrane, with a root barrier, if it has failed. Damp walls behind garden beds Bridged damp-proof course or irrigation. Inspection.Lower the beds, pull mulch back from walls, vents and barriers, and redirect any irrigation.
What you see Likely cause, and what confirms it Next step Dense vegetation or mulch against the building in a bushfire-prone area Fuel at the building edge. Bushfire attack level assessment; vegetation and separation.Manage vegetation to the assessed level, and keep a clear zone around the building. Gutters full of leaves and timber decks against the building Ember ignition points. Inspection of gutters, decks and openings.Clear gutters, fit guards and ember screens, and replace combustible items near the building.
What you see Likely cause, and what confirms it Next step Block cracking across the whole surface Asphalt ageing. Age; no wheel-path pattern.Seal the cracks and reseal the surface; the base is sound. Alligator cracking in wheel paths Structural failure of the base. Cores; deflection testing.Repair the base full depth; resealing over it wastes money. Ruts in truck routes Overloading or weak asphalt. Traffic type; asphalt mix.Rebuild the truck routes for the traffic, in concrete where trucks turn and stand. Potholes after rain Water through cracks into base. Crack pattern; drainage.Patch full depth, seal the cracks, and fix the drainage that lets water in.
What you see Likely cause, and what confirms it Next step Stepped concrete panels Subgrade softening or pumping. Water at joints; voids.Find and stop the water at the joints; lift slabs by grout or replace panels. Sunken pavers near pits or edges Bedding washout or edge failure. Lift pavers; inspect.Relay on new bedding with edge restraints.
What you see Likely cause, and what confirms it Next step Lifted pavers, slab edges or tree-root heave on a footpath Trip hazard. Level change measured against the asset’s market (Thresholds by market ).Grind, relay or ramp the lip, and record the repair. Accessible parking bays narrow or with no shared zone Bay layout below current requirements. Bay and aisle widths against the asset’s market (Thresholds by market ).Remark the bays to current layout.
What you see Likely cause, and what confirms it Next step Bare ground under swings and slides Loose fill displaced. Depth measurement.Close the equipment until the loose fill is topped up to the depth its fall height needs. Rubber surfacing hard to the touch Aged surfacing. Impact attenuation test.Test the impact attenuation; replace surfacing that fails. Equipment wobbling Loose fixings or rotted posts. Inspection.Close it; tighten the fixings or replace rotted posts.
What you see Likely cause, and what confirms it Next step Cracks repeating through court surfaces Base movement or shrinkage. Crack mapping.Map the cracks; treat and resurface, or rebuild the base if the cracking is structural. Frayed gym cables Wear. Inspection.Take the machine out of use and replace the cable.
What you see Likely cause, and what confirms it Next step Barbecue gas bottles or hoses damaged, or no gas isolation Gas leak or fire risk. Inspection and leak test of the gas installation.Repair to the gas installation standard, and fit an isolation valve. Shade sail sagging or fixings corroded Wind failure risk. Fixings and masts; wind rating; storm removal practice.Replace the fixings and set a storm procedure. Dark paths and play areas at night Failed or inadequate lighting. Night inspection; lux readings.Repair or add lighting.
What you see Likely cause, and what confirms it Next step Ponding at one pit after every storm Blocked pit or pipe. Inspection; CCTV.Clear the pit and pipe; survey by CCTV if it recurs. Repeated blockage downstream of trees Root intrusion. CCTV.Cut the roots as an interim, then reline or replace the damaged pipe. Damp behind retaining walls and under slabs Blocked subsoil drains. Inspection; flushing.Flush the subsoil drains, and renew them if they cannot be cleared. Long, flat stormwater runs silting up Gradient too shallow. Levels survey against the asset’s market (Thresholds by market ).Relay the run to fall, or add access for regular flushing.
What you see Likely cause, and what confirms it Next step Detention tank never empties or empties instantly Blocked orifice or missing orifice plate. Inspection.Clear or replace the orifice plate and screens, remove sediment, and reinstate accessible covers. Treatment devices or pit baskets full of litter and sediment Maintenance lapsed. Device inspection; maintenance records against the agreement.Clean the devices and set a maintenance schedule.
What you see Likely cause, and what confirms it Next step Site floods in large storms only Overland flow blocked or system capacity exceeded. Flow path review; design capacity.Check the overland flow path first, then the design capacity; restore the path before upsizing pipes. Water entering the building at a low threshold in storms Overland flow reaching the building. Levels at thresholds against the flow path.Raise thresholds, regrade, or add grated drains at the entry.
Nothing matches that. Try fewer letters.