Every sign of failure the Technical Library records under External Elements: 48 signs across 6 elements and spaces. Each row gives what you see, the likely cause and what confirms it, and the next step. Each heading opens the page the rows come from.

Ancillary Structures

Wind, decay and impact

What you seeLikely cause, and what confirms itNext step
Pergola or carport leaningPost base decay or impact damage. Probe or inspect at ground level.Exclude people if it stands over a used area; replace the decayed posts on stirrups or with steel.
Shade sail masts bent after a stormWind overload; sail not removed. Inspection; design wind rating.Take the sail down; upgrade the masts and footings to an engineered design, and set take-down procedures.
Rust bleeding from a flagpole or sign baseCorrosion at the base and possible fatigue. Inspection; non-destructive testing of welds.Inspect the base and welds; repair or replace a corroded base, and replace a pole with fatigue cracking.
Bin store, shed or carport roof sheets liftingFixings inadequate for wind. Fixing type and spacing; corrosion.Refix the sheets with suitable fixings, and check the frame.

Asbestos, fire and water features

What you seeLikely cause, and what confirms itNext step
Cracked cement sheeting on an old shedWeathered asbestos cement. Sampling.Sample it; plan licensed removal, or encapsulate it where it is sound and undisturbed.
Algae and slime in a water featureInadequate treatment. Water testing.Test the water; treat it, or decommission the feature.

Unapproved structures

What you seeLikely cause, and what confirms itNext step
Structure with no record of approvalInformal addition. Council or authority records.Check council or authority records; obtain retrospective approval or remove the structure.
Structure close to a boundary or another building, built of combustible materialsPossible fire spread. Distance to boundaries and buildings; materials.Check against fire separation rules, and relocate or line the structure if required.

Fencing, Gates & Signage

Powered gates and pool barriers

What you seeLikely cause, and what confirms itNext step
Powered gate does not reverse when it meets an obstructionForce limitation or safety edge failure. Force measurement; device test.Disable the gate now; restore force limitation and safety edges, and test them.
Gate jerks, jumps or leaves the trackWorn rollers, track or stops. Inspection.Replace worn rollers, track or stops before the gate derails.
Pool gate stays open from some positionsHinge tension or latch fault. Test from several open positions, and measure the barrier against the asset’s market (Thresholds by market).Close the pool until fixed; adjust the hinge tension or replace the latch, and retest from every position.
Pedestrian gate on an accessible route too narrow or heavy to openAccess barrier. Clear width and opening force against the asset’s market (Thresholds by market).Widen the gate, adjust the closer, or fit a powered operator.

Fences, walls and boundaries

What you seeLikely cause, and what confirms itNext step
Fence leaning in sectionsPost base decay. Probe posts.Replace the posts on galvanised stirrups or with steel.
Boundary wall leaning with a tree nearbyRoot pressure or foundation movement. Inspection; engineer.Have an engineer assess it; repair or rebuild it with the neighbour's agreement.

Signage

What you seeLikely cause, and what confirms itNext step
Exit signs pointing to a removed doorLayout changed without updating signs. Walkthrough against plans.Walk the routes against the plans and update the signs.
Safety signs faded, missing or inconsistentSigns no longer effective. Signage audit against the site’s hazards.Replace with signs to the relevant standard.

Landscaping & Irrigation

Trees and roots

What you seeLikely cause, and what confirms itNext step
Cracks in a building near a large tree on claySubsidence from root moisture uptake. See foundations page.Assess the foundations before acting on the tree; on clay, removing it can cause heave.
Repeated drain blockages near treesRoot intrusion. CCTV.Survey by CCTV, clear and repair the drain, and fit a root barrier.
Dead branches in a tree crownDecline, decay or root damage. Arborist assessment.Get an arborist's assessment and act on it; exclude people below if the tree is over an occupied area.
Tree works planned near a building or new constructionRoot damage or removal affecting the tree or the building. Tree protection zone set by an arborist.Fence the protection zone before works start.

Planters, irrigation and the building's edge

What you seeLikely cause, and what confirms itNext step
Leaks in a car park under a planterMembrane failure or blocked drainage. Flood test; drainage inspection.Flood test the planter and clear its drainage; replace the membrane, with a root barrier, if it has failed.
Damp walls behind garden bedsBridged damp-proof course or irrigation. Inspection.Lower the beds, pull mulch back from walls, vents and barriers, and redirect any irrigation.

Vegetation and bushfire

What you seeLikely cause, and what confirms itNext step
Dense vegetation or mulch against the building in a bushfire-prone areaFuel at the building edge. Bushfire attack level assessment; vegetation and separation.Manage vegetation to the assessed level, and keep a clear zone around the building.
Gutters full of leaves and timber decks against the buildingEmber ignition points. Inspection of gutters, decks and openings.Clear gutters, fit guards and ember screens, and replace combustible items near the building.

Pavements & Hardstand

Asphalt: ageing, cracking and potholes

What you seeLikely cause, and what confirms itNext step
Block cracking across the whole surfaceAsphalt ageing. Age; no wheel-path pattern.Seal the cracks and reseal the surface; the base is sound.
Alligator cracking in wheel pathsStructural failure of the base. Cores; deflection testing.Repair the base full depth; resealing over it wastes money.
Ruts in truck routesOverloading or weak asphalt. Traffic type; asphalt mix.Rebuild the truck routes for the traffic, in concrete where trucks turn and stand.
Potholes after rainWater through cracks into base. Crack pattern; drainage.Patch full depth, seal the cracks, and fix the drainage that lets water in.

Concrete and paved surfaces

What you seeLikely cause, and what confirms itNext step
Stepped concrete panelsSubgrade softening or pumping. Water at joints; voids.Find and stop the water at the joints; lift slabs by grout or replace panels.
Sunken pavers near pits or edgesBedding washout or edge failure. Lift pavers; inspect.Relay on new bedding with edge restraints.

Trip hazards

What you seeLikely cause, and what confirms itNext step
Lifted pavers, slab edges or tree-root heave on a footpathTrip hazard. Level change measured against the asset’s market (Thresholds by market).Grind, relay or ramp the lip, and record the repair.
Accessible parking bays narrow or with no shared zoneBay layout below current requirements. Bay and aisle widths against the asset’s market (Thresholds by market).Remark the bays to current layout.

Recreational Facilities

Playgrounds: surfacing, entrapment and wear

What you seeLikely cause, and what confirms itNext step
Bare ground under swings and slidesLoose fill displaced. Depth measurement.Close the equipment until the loose fill is topped up to the depth its fall height needs.
Rubber surfacing hard to the touchAged surfacing. Impact attenuation test.Test the impact attenuation; replace surfacing that fails.
Equipment wobblingLoose fixings or rotted posts. Inspection.Close it; tighten the fixings or replace rotted posts.

Courts and gyms

What you seeLikely cause, and what confirms itNext step
Cracks repeating through court surfacesBase movement or shrinkage. Crack mapping.Map the cracks; treat and resurface, or rebuild the base if the cracking is structural.
Frayed gym cablesWear. Inspection.Take the machine out of use and replace the cable.

Lighting, barbecues and shade

What you seeLikely cause, and what confirms itNext step
Barbecue gas bottles or hoses damaged, or no gas isolationGas leak or fire risk. Inspection and leak test of the gas installation.Repair to the gas installation standard, and fit an isolation valve.
Shade sail sagging or fixings corrodedWind failure risk. Fixings and masts; wind rating; storm removal practice.Replace the fixings and set a storm procedure.
Dark paths and play areas at nightFailed or inadequate lighting. Night inspection; lux readings.Repair or add lighting.

Stormwater Drainage

Blocked pits, pipes and subsoil drains

What you seeLikely cause, and what confirms itNext step
Ponding at one pit after every stormBlocked pit or pipe. Inspection; CCTV.Clear the pit and pipe; survey by CCTV if it recurs.
Repeated blockage downstream of treesRoot intrusion. CCTV.Cut the roots as an interim, then reline or replace the damaged pipe.
Damp behind retaining walls and under slabsBlocked subsoil drains. Inspection; flushing.Flush the subsoil drains, and renew them if they cannot be cleared.
Long, flat stormwater runs silting upGradient too shallow. Levels survey against the asset’s market (Thresholds by market).Relay the run to fall, or add access for regular flushing.

Detention and treatment

What you seeLikely cause, and what confirms itNext step
Detention tank never empties or empties instantlyBlocked orifice or missing orifice plate. Inspection.Clear or replace the orifice plate and screens, remove sediment, and reinstate accessible covers.
Treatment devices or pit baskets full of litter and sedimentMaintenance lapsed. Device inspection; maintenance records against the agreement.Clean the devices and set a maintenance schedule.

Overland flow and capacity

What you seeLikely cause, and what confirms itNext step
Site floods in large storms onlyOverland flow blocked or system capacity exceeded. Flow path review; design capacity.Check the overland flow path first, then the design capacity; restore the path before upsizing pipes.
Water entering the building at a low threshold in stormsOverland flow reaching the building. Levels at thresholds against the flow path.Raise thresholds, regrade, or add grated drains at the entry.