Every sign of failure the Technical Library records under Substructure: 32 signs across 4 elements and spaces. Each row gives what you see, the likely cause and what confirms it, and the next step. Each heading opens the page the rows come from.
Scope
A sign usually has more than one possible cause. Each row names the likely one and what would confirm it; none is a diagnosis of a particular building, and none is a price.
What you see Likely cause, and what confirms it Next step Basement leaks only in wet weather Surface water reaching the wall. Correlation with rainfall; surface drainage.Fix the surface drainage: regrading, channels and downpipe connections. Basement leaks all year Groundwater. Groundwater levels.Inject cracks and joints; where external access is impossible, fit a drained cavity system with sumps and pumps. High radon result in a basement or cellar Ground gas entering through the floor and walls. A long-term test; the US EPA recommends fixing homes at 4 pCi/L (150 Bq/m³) or more (US EPA ), and in the UK the risk is relatively low below 100 Bq/m³ (UKradon ).Seal entry points and fit a radon sump or ventilation, then retest.
What you see Likely cause, and what confirms it Next step Retaining wall leaning more after heavy rain Blocked drainage and water pressure. Weep holes and drains inspected.Clear the drains and open the weep holes; keep people and loads away, and get an engineer's assessment. Wall cracked behind a new driveway or structure Surcharge. Loads against design.Remove the surcharge, or redesign the wall for it. Inward bowing of cellar walls Lack of restraint and earth pressure. Survey; restraint details.Get an engineer's assessment; restraint, buttresses or anchors. Cracks in a basement or retaining wall widening between readings Movement still active. Crack widths read against fixed points over time, and graded on the asset’s market’s damage scale (Thresholds by market ).Keep reading the cracks, and have an engineer assess any crack that is still moving or has reached the moderate band.
What you see Likely cause, and what confirms it Next step Timber wall leaning with soft posts Decay below ground. Probe posts.Replace the sleeper wall with a concrete or masonry system.
What you see Likely cause, and what confirms it Next step Diagonal cracks widening toward the top at one corner, near a large tree Subsidence from clay shrinkage. Seasonal crack opening; soil moisture and root analysis; crack widths graded on the asset’s market’s damage scale (Thresholds by market ).Find the cause, usually a tree or a leak; remove it, then monitor before deciding on underpinning. Cracks widening in summer and closing in winter Seasonal clay movement. Twelve months of crack monitoring.Monitor for twelve months; manage trees and drainage; repair the cracks once stable. Floors lifting in the middle, cracks wider at the top of internal walls Heave after tree removal or leaks. Level survey; history of tree removal.Survey the levels and stop any leaks; assess heave before any further tree removal.
What you see Likely cause, and what confirms it Next step Sudden local drop near a drain run Washout from a leaking drain. Drain CCTV; void detection.Repair the drain, then stabilise the ground, by underpinning or resin injection if needed. Crack between extension and original building Different foundations moving differently. Foundation depths; level survey.Establish both foundation depths and monitor; underpin only if movement continues. Floors out of level across an internal wall line Differential movement of the footings. Level survey with a straight edge, graded on the asset’s market’s floor scale (Thresholds by market ).Map the levels and find the cause, then monitor before deciding on underpinning.
What you see Likely cause, and what confirms it Next step Uneven floors in a house on timber stumps Decayed or sunken stumps. Sub-floor inspection.Restump with concrete or steel stumps, and re-level the floors.
What you see Likely cause, and what confirms it Next step Building tilting slowly over a wide area Mine subsidence or regional settlement. Mining records; survey.Check the mining records and survey; in mine subsidence districts, claim through the relevant scheme.
What you see Likely cause, and what confirms it Next step Fine random cracks, no displacement Drying shrinkage. Pattern; age; stability.No structural repair; route and seal them where they affect finishes. Panel corners rocking at joints Curling. Level survey across joints.Grout under the lifted panels and grind the high edges. Slab dished near the centre or edges dropping Settlement or clay shrinkage. Level survey and soil investigation, with offsets graded on the asset’s market’s floor scale (Thresholds by market ).Investigate the soil; lift and stabilise by injection, or manage the loads. Racking leaning Floor out of level or settlement under baseplates. Survey.Survey the floor; add baseplates, relocate the racking, or stabilise the slab. Cracks in a house slab that have opened over a year Movement beyond drying shrinkage. Crack width graded on the asset’s market’s slab scale (Thresholds by market ).Monitor widths and levels, and have an engineer assess cracks in the moderate band or above.
What you see Likely cause, and what confirms it Next step Broken joint edges in forklift aisles Wheel impact on open joints. Joint width; forklift wheel type.Rebuild the arrises; install armoured joints in heavy-traffic aisles.
What you see Likely cause, and what confirms it Next step Floor finish blistering or debonding Moisture vapour through the slab. In-situ relative humidity testing.Test the slab's relative humidity; lay a surface membrane before new flooring. New flooring planned over a recent or damp slab Slab moisture not yet tested. In-situ relative humidity probes to ASTM F2170, read against the limit the flooring manufacturer sets.Test before laying; use a moisture-tolerant system or a surface membrane where the reading exceeds the limit.
What you see Likely cause, and what confirms it Next step Soft joist ends at external walls Wet rot from damp walls or blocked vents. Moisture readings.Clear the vents and lower the ground levels; replace the decayed timber. White strands across masonry and fruiting bodies Dry rot. Identification.Remove the moisture source; cut out affected timber well beyond the visible damage, and treat the masonry. Damp ground or standing water under the floor Water reaching the sub-floor. Inspection after rain; ground falls; downpipe and plumbing discharge.Regrade, connect downpipes, fix leaks, and lay a ground membrane where the ground stays damp.
What you see Likely cause, and what confirms it Next step Uneven floors in a house on timber stumps Decayed or sunken stumps. Sub-floor inspection.Restump, and replace decayed bearers and joists. Hollow timbers with mud Termites. Inspection; termite detection.Treat with chemical barriers or baiting, fix ant caps and remove bridges; replace damaged timber. Floor framing close to the ground No room to ventilate or inspect. Ground clearance under the lowest member against the asset’s market (Thresholds by market ).Lower the ground or improve access, and keep the clearance clear of stored material.
What you see Likely cause, and what confirms it Next step Musty smell and mould Poor ventilation or damp ground. Humidity and ventilation check, with vent area against the asset’s market (Thresholds by market ).Clear and add vents, lay a ground vapour barrier, or add mechanical ventilation. Damp only below one area Plumbing leak or downpipe discharge. Inspection.Fix the plumbing leak or downpipe.
Nothing matches that. Try fewer letters.
Moyne Ross
Technical Library · Updated 14 November 2026