The same part of a building goes by different names in Australia, the United Kingdom and the United States, and so do the leases, codes and reports around it. This page sets 120 of them side by side, with the Technical Library page that covers each.
Ownership, leases and reports
Ownership, leases and reports
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| Ownership of a unit in a multi-owner buildingThese are different legal structures, not just different words. Who owns and pays for the structure and the common parts differs in each.See Common Internal Areas | Strata title, run by an owners corporation or body corporate | Leasehold under a freeholder, or commonhold; often run through a residents’ management company | Condominium, run by a condominium or homeowners’ association |
| The fund owners pay into for major future worksSee Common Internal Areas | Capital works fund, sinking fund or maintenance fund, depending on the state | Reserve fund or sinking fund | Reserve fund, sized by a reserve study |
| Putting premises back at the end of a leaseSee Commercial Office Areas (Base-Build), Retail Tenancies (Base-Build) | Make good | Dilapidations; reinstatement | Restoration or surrender obligations |
| The technical report commissioned before buying a building | Technical due diligence (TDD) report | Technical due diligence report or building survey | Property condition assessment (PCA), usually to ASTM E2018 |
| What the landlord provides before the tenant fits outThe line between landlord’s and tenant’s works is set by the lease, not by the label.See Commercial Office Areas (Base-Build), Retail Tenancies (Base-Build) | Base building; cold shell or warm shell | Shell and core; Category A (Cat A) | Core and shell; warm shell or vanilla shell |
| The tenant’s own interior worksSee Commercial Office Areas (Base-Build), Retail Tenancies (Base-Build) | Fit-out | Fit-out; Category B (Cat B) | Tenant improvements (TI); build-out |
| Building running costs recovered from tenants | Outgoings | Service charge | Operating expenses; common area maintenance (CAM) charges |
| The floor area a commercial lease is measured onThe three methods treat columns, common areas and wall thickness differently, so areas are not directly comparable. | Net lettable area (NLA), to the Property Council method of measurement | Net internal area (NIA), to RICS measurement standards | Rentable area, to BOMA standards |
| The storey at street level, and the one above itA US “third floor” is usually an Australian or British “second floor”. | Ground floor, then Level 1 or first floor | Ground floor, then first floor | First floor, then second floor |
Codes and compliance
Codes and compliance
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The building code | National Construction Code (NCC), formerly the Building Code of Australia (BCA) | Building Regulations and their Approved Documents in England; separate regulations in Scotland, Wales and Northern Ireland | Model codes (IBC, IFC, NFPA) as adopted and amended by each state and city |
| How the code classifies a building by useIn Britain, “use classes” belong to planning law, not the building regulations. | NCC classes, such as Class 2 apartments and Class 5 offices | Purpose groups in Approved Document B | Occupancy groups in the IBC, such as Group B business and Group R residential |
| The sign-off that a building may be occupied | Occupancy permit or occupation certificate, depending on the state | Completion certificate from building control | Certificate of occupancy |
| The law and standards on access for people with disabilitySee Disabled Access (DDA) | Disability Discrimination Act 1992, the Premises Standards and AS 1428.1 | Equality Act 2010, Approved Document M and BS 8300 | Americans with Disabilities Act (ADA), the 2010 ADA Standards and ICC A117.1 |
| The energy rating a commercial building is known byNABERS and ENERGY STAR rate measured energy use; an EPC rates the building as designed and built.See Energy Efficiency Upgrades | NABERS Energy rating | Energy Performance Certificate (EPC), with minimum standards under MEES | ENERGY STAR score, with building performance standards in some cities and states |
| The standard that sets routine servicing of fire systemsSee Automatic Sprinkler Systems, Fire Detection & Alarm Systems | AS 1851 | A British Standard for each system, such as BS 5839-1 for alarms and BS EN 12845 for sprinklers | NFPA 25 for water-based systems and NFPA 72 for alarms |
| The owner’s recurring fire safety obligationThese are different instruments. Each market’s is described on the pages for the systems it covers.See Passive Fire Protection, Integrated Building Systems | Essential safety measures reporting or an annual fire safety statement, depending on the state | A fire risk assessment, kept under review, under the Fire Safety Order in England and Wales | Inspection, testing and maintenance records required by the adopted fire code |
| Workplace health and safety lawSee Occupational Health & Safety (OHS) | Work health and safety (WHS); occupational health and safety (OHS) in Victoria | Health and safety law, including the CDM Regulations for construction work | OSHA regulations |
| The framework for controlling Legionella in water systemsSee Heat Rejection Plant, Hot & Warm Water Plant | AS/NZS 3666 and state risk management requirements | Approved Code of Practice L8 and HSG274 | ASHRAE Standard 188 water management program |
| The record of asbestos in a buildingSee Hazardous Materials | Asbestos register and management plan | Asbestos register and management plan, from a management survey | Asbestos survey and operations and maintenance (O&M) program |
| The first-stage land contamination report | Preliminary site investigation (PSI) | Phase 1 desk study | Phase I Environmental Site Assessment, to ASTM E1527 |
| Fire spreading from vegetation, and how the code rates exposure to itSee Landscaping & Irrigation | Bushfire; Bushfire Attack Level (BAL) under AS 3959 | Wildfire; no rating in the building regulations | Wildfire; wildland-urban interface (WUI) codes |
Structure and ground
Structure and ground
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The part of the structure that bears on the groundSee Foundations | Footings | Foundations | Footings and foundations |
| A concrete floor cast directly on the groundSee Slab on Ground | Slab on ground | Ground-bearing slab | Slab-on-grade |
| Clay that swells when wet and shrinks when drySee Foundations | Reactive clay | Shrinkable clay | Expansive soil |
| The space under a suspended ground floorSee Sub-floor & Crawlspace | Sub-floor | Sub-floor void | Crawl space |
| What holds up a suspended timber ground floorSee Sub-floor & Crawlspace | Stumps or piers, bearers and joists | Sleeper walls, wall plates and joists | Piers, girders and joists |
| Replacing failed supports under a timber floorSee Sub-floor & Crawlspace, Foundations | Restumping or reblocking | No direct equivalent; timber floors usually rest on masonry sleeper walls | Pier replacement; house leveling |
| Concrete breaking away as the steel inside it rustsSee Structural Frame | Concrete cancer; spalling | Spalling; reinforcement corrosion | Spalling; rebar corrosion; delamination |
| Steel bars cast into concreteSee Structural Frame | Reinforcement; reo | Reinforcement; rebar | Rebar |
| Keeping water out of a basementSee Basement, Cellars & Retaining Walls | Basement waterproofing; tanking | Tanking; basement waterproofing (Types A, B and C) | Basement or below-grade waterproofing |
Roofs and rainwater
Roofs and rainwater
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The pipe that carries roof water down the buildingSee Rainwater Systems | Downpipe | Downpipe; rainwater pipe | Downspout; leader |
| A gutter built in behind a parapet or between roofsSee Rainwater Systems | Box gutter | Box gutter; parapet gutter | Built-in gutter; internal gutter |
| The collector box at the top of a downpipeSee Rainwater Systems | Rainhead | Hopper head | Conductor head; leader head |
| An opening through a parapet that lets water off the roofSee Rainwater Systems | Overflow; parapet outlet | Overflow; chute outlet | Scupper |
| The sheet laid under tiles or metal roofingIn Scotland “sarking” means the timber boards under the slates, not the sheet.See Roof Coverings, Insulation | Sarking | Roofing underlay | Underlayment |
| A near-flat roof and its waterproofingSee Waterproofing Membranes | Flat roof; membrane roof | Flat roof; felt, asphalt or single-ply covering | Low-slope roof; built-up, modified bitumen or single-ply roofing |
| Profiled steel roofingSee Roof Coverings | Metal roof sheeting; corrugated iron | Profiled metal sheeting | Metal roofing; corrugated or standing seam panels |
| Glazing set into a roofSee Skylights, Dormers & Glazed Atria | Skylight | Rooflight | Skylight |
| The space between the ceiling and a pitched roofSee Roof Structure, Maintenance Access Areas | Roof space | Loft; roof void | Attic |
| The weathering cap on top of a parapet wallSee Plant Screens & Parapets | Capping; coping | Coping | Coping; parapet cap |
| A fixed cable roof workers clip on toSee Roof Safety Systems | Static line | Horizontal lifeline, often called a mansafe system | Horizontal lifeline |
| The fixed systems that stop people falling from roofsSee Roof Safety Systems | Height safety systems: anchors, static lines and guardrails | Fall protection; work at height systems | Fall protection systems |
Walls, façades and openings
Walls, façades and openings
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| A single skin of brick outside a timber or steel frameSee Masonry/Brickwork | Brick veneer | Brick-clad timber frame | Brick veneer |
| Two skins of masonry with a gap betweenSee Masonry/Brickwork, Load-Bearing Masonry | Cavity brick; double brick | Cavity wall, with an inner and outer leaf | Cavity wall, with an inner and outer wythe |
| A cement or lime coat applied to an outside wallSee External Coating Systems | Render | Render; roughcast or harling in Scotland | Stucco |
| Insulation board fixed to a wall and finished with thin renderSee Cladding & Wall Systems | EIFS; rendered polystyrene cladding | External wall insulation (EWI); insulated render | EIFS; synthetic stucco |
| Thin metal-faced sandwich panels used as claddingSee Cladding & Wall Systems | Aluminium composite panel (ACP) | Aluminium composite material (ACM) | Metal composite material (MCM); ACM |
| Overlapping boards on an outside wallSee Cladding & Wall Systems | Weatherboards | Weatherboarding; timber cladding | Siding; clapboard |
| Older cement sheet that contains asbestosSee Hazardous Materials | Asbestos cement sheet; fibro | Asbestos cement | Asbestos cement; transite |
| Heat-treated safety glass that breaks into small piecesSee Glazing Systems | Toughened glass | Toughened glass | Tempered glass |
| A sealed double-glazed paneSee Glazing Systems | Insulating glass unit (IGU); double-glazed unit | Double-glazed unit; sealed unit | Insulating glass unit (IGU) |
| Flexible filler in a jointSee Sealants & Joints | Sealant; caulking | Sealant; mastic | Caulk; sealant |
| The barrier at the edge of a balcony, stair or dropIn US codes the “handrail” is the rail you hold and the “guard” is the barrier; they are separate requirements.See Verandahs, Balconies & Balustrades | Balustrade | Balustrade; guarding | Guard; guardrail |
| A roof projecting over the public path outside a shopSee Canopies & Awnings | Awning over the footpath | Canopy over the pavement | Canopy or marquee over the sidewalk |
| Permanent roof-mounted equipment for reaching the façadeSee Building Maintenance Units (BMU) | Building maintenance unit (BMU) | Building maintenance unit (BMU); cradle | Building maintenance unit (BMU); powered platform |
| The wall between two tenanciesSee Partitioning Systems, Retail Tenancies (Base-Build) | Inter-tenancy wall | Demising wall; party wall where it divides ownerships | Demising wall |
| The metal ties that hold the outer skin of brick to the wall behindSee Masonry/Brickwork | Brick ties; wall ties | Wall ties; cavity wall ties | Brick ties; masonry ties |
Interiors and external works
Interiors and external works
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| Paper-faced gypsum wall and ceiling liningSee Internal Wall & Ceiling Finishes, Partitioning Systems | Plasterboard | Plasterboard | Drywall; gypsum board |
| A tile ceiling hung on a grid below the slabSee Internal Wall & Ceiling Finishes | Suspended ceiling | Suspended ceiling | Drop ceiling; acoustical ceiling tile (ACT) |
| Shared toilets in a commercial buildingSee Public Amenities | Amenities; toilets | Toilets; WCs | Restrooms |
| Bike parking, showers and lockers for commutersSee Public Amenities | End-of-trip facilities | Cycle storage and showers | Bike room and showers |
| Shelving that slides on rails to close the aislesLoaded bays are heavy enough that the floor’s capacity needs checking.See Storage & Archive Areas | Compactus | Mobile shelving; roller racking | High-density mobile shelving |
| The cooking surface and the extract above itSee Kitchen | Cooktop and rangehood | Hob and cooker hood | Cooktop or range, and range hood |
| The kitchen work surfaceSee Kitchen | Benchtop | Worktop | Countertop |
| The paved public path beside a roadIn the US “pavement” means the road or car park surface itself.See Pavements & Hardstand | Footpath | Pavement; footway | Sidewalk |
| Bitumen-bound surfacing for roads and car parksSee Pavements & Hardstand | Asphalt; bitumen | Asphalt; tarmac | Asphalt; blacktop |
| Where cars are parkedSee Pavements & Hardstand, Structural Frame | Car park | Car park; multi-storey car park | Parking lot; parking garage or parking structure |
| A room that gets wet and must be waterproofedSee Bathrooms & Wet Areas | Wet area: bathrooms, showers, laundries and toilets | Bathroom or shower room; a wet room is a level-access shower room with no tray | Bathroom; shower waterproofing |
| The fittings that make a door workSee Internal Doors & Hardware | Door hardware | Ironmongery | Door hardware; panic hardware for exit devices |
| A door of slats that rolls up above the openingSee Loading Docks & Goods Handling | Roller shutter; roller door | Roller shutter | Roll-up door; overhead door |
Heating, cooling and ventilation
Heating, cooling and ventilation
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The engineering services of a building, as a group | Building services: mechanical, electrical, hydraulic and fire | M&E; building services | MEP: mechanical, electrical and plumbing |
| The system that monitors and controls plantSee Building Management & Control System (BMCS) | Building management system (BMS); BMCS | Building management system (BMS) | Building automation system (BAS) |
| A small air conditioner with separate indoor and outdoor unitsSee Localised HVAC | Split system; reverse-cycle where it also heats | Split system | Mini-split; ductless split |
| A self-contained air conditioner on the roof serving ducts belowSee Localised HVAC, Air Handling Units (AHUs) | Packaged unit; rooftop package | Packaged rooftop unit | Rooftop unit (RTU) |
| Plant that makes domestic hot waterSee Hot & Warm Water Plant | Hot water unit; hot water system | Water heater; calorifier; cylinder | Water heater |
| Ventilation that recovers heat from the exhaust airSee Ventilation Systems | Heat recovery ventilation (HRV); energy recovery ventilation (ERV) | Mechanical ventilation with heat recovery (MVHR) | Heat recovery ventilator (HRV); energy recovery ventilator (ERV) |
| A ventilated enclosure for laboratory workSee Specialised Occupancy Areas, Ventilation Systems | Fume cupboard | Fume cupboard | Fume hood |
| The hood and duct that remove cooking fumes and greaseSee Commercial Kitchens, Ventilation Systems | Kitchen exhaust hood and duct | Kitchen extract canopy and ductwork | Kitchen exhaust hood (Type I) and grease duct |
| The unit of fans, filters and coils that conditions and moves air into ductsSee Air Handling Units (AHUs) | Air handling unit (AHU) | Air handling unit (AHU) | Air handler; air handling unit (AHU) |
Electrical
Electrical
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The board where the supply enters and is dividedSee Main Electrical Supply | Main switchboard (MSB) | Main LV switchboard; main intake | Main switchboard or switchgear; service entrance |
| A local board feeding final circuitsSee Power Distribution | Distribution board (DB) | Distribution board; consumer unit in a dwelling | Panelboard; panel; load center in a dwelling |
| The device that cuts power on leakage to earth, to protect peopleA US GFCI trips at a lower leakage current than the 30 mA RCD usual in Australia and Britain.See Power Distribution | RCD; safety switch | RCD | GFCI |
| Connecting an installation to the groundSee Power Distribution, Lightning Protection | Earthing | Earthing | Grounding |
| Where an appliance plugs inSee Power Distribution | Power point; socket outlet; GPO | Socket; socket-outlet | Receptacle; outlet |
| A complete light unitSee Lighting | Light fitting; luminaire | Luminaire; light fitting | Light fixture |
| The company that owns the local electricity networkSee Main Electrical Supply | Distributor; network service provider | Distribution network operator (DNO) | Utility |
| Routine inspection and test of an existing installationSee Power Distribution | Periodic verification or assessment, to AS/NZS 3019 where it is called for | Electrical Installation Condition Report (EICR), to BS 7671 | No general equivalent; maintenance to NFPA 70B |
| A landlord-owned network that resells power to occupiersSee Sub-metering | Embedded network | Landlord’s supply with sub-meters | Master-metered building with submeters |
| The sign that marks the way outSee Emergency Lighting | Exit sign, with a green running-man pictogram | Fire exit sign, with a green running-man pictogram | Exit sign, usually the word EXIT in red or green |
| A generator that takes over when the mains supply failsSee Emergency Power | Standby generator; backup generator | Standby generator | Emergency generator for life-safety loads; standby generator for the rest |
Fire
Fire
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The public fire service | Fire brigade; fire and rescue service | Fire and rescue service | Fire department |
| The panel that shows and controls the fire alarm systemSee Fire Detection & Alarm Systems | Fire indicator panel (FIP) | Fire alarm control panel | Fire alarm control panel (FACP) |
| The system that sounds tones and spoken messages to evacuateSee Fire Detection & Alarm Systems | Emergency warning and intercommunication system (EWIS) | Voice alarm (VA) system | Emergency voice/alarm communication system (EVACS) |
| The fixed pipe with outlets on each floor for firefighters’ hosesSee Hydrant & Hose Reel Systems | Fire hydrant system | Dry or wet rising main, with landing valves | Standpipe system, with hose valves |
| Where the fire service pumps water into the building’s systemSee Hydrant & Hose Reel Systems, Fire Pumping Systems | Booster assembly | Dry riser inlet; breeching inlet | Fire department connection (FDC) |
| The sprinkler design standardSee Automatic Sprinkler Systems | AS 2118 | BS EN 12845 | NFPA 13 |
| How fire resistance is writtenSee Passive Fire Protection | Fire-resistance level (FRL), such as 90/90/90 | Fire resistance in minutes, such as REI 90 | Hourly rating, such as 1½-hour |
| How a fire door’s rating is writtenSee Passive Fire Protection, Internal Doors & Hardware | FRL, such as -/60/30 | FD30 or FD60, with an S suffix for smoke seals | Minutes or hours, such as 20-minute or 90-minute |
| A wall built to stop fire spreading through the buildingSee Passive Fire Protection | Fire wall; fire-rated wall | Compartment wall | Fire wall; fire barrier |
| Sealing gaps and service holes in fire-rated walls and floorsSee Passive Fire Protection | Fire stopping; penetration sealing | Fire stopping | Firestopping |
| A stair enclosed in fire-rated construction for escapeSee Internal Stairwells | Fire-isolated stair | Protected stair | Interior exit stairway; exit stair enclosure |
| The route out of a building in a fireSee Internal Stairwells, Common Circulation Areas | Exits and paths of travel to them | Means of escape | Means of egress |
| An opening that releases smoke automaticallySee Smoke Management Systems | Smoke and heat vent | Automatic opening vent (AOV) | Smoke and heat vent |
| Fans that keep smoke out of escape stairsSee Smoke Management Systems | Stair pressurisation | Pressure differential system; stair pressurisation | Stair pressurization |
Water and drainage
Water and drainage
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The water, drainage and gas services, as a disciplineOutside Australia “hydraulic” usually means oil-powered machinery, such as a hydraulic lift.See Water Supply, Sanitary & Drainage Systems | Hydraulic services | Public health engineering; plumbing and drainage | Plumbing |
| Drainage that carries waste from toilets, basins and sinksSee Sanitary & Drainage Systems | Sewer; sanitary drainage | Foul drainage | Sanitary sewer; sanitary drainage |
| Drainage that carries rain off the siteSee Stormwater Drainage | Stormwater drainage | Surface water drainage | Storm drainage; storm sewer |
| Holding rain on site and releasing it slowlySee Stormwater Drainage | On-site detention (OSD) | Attenuation, as part of sustainable drainage (SuDS) | Stormwater detention |
| The tank that catches kitchen grease before the sewerSee Trade Waste Systems | Grease arrestor; grease trap | Grease trap; grease separator | Grease interceptor; grease trap |
| Non-domestic liquid waste discharged to the sewer under a permitSee Trade Waste Systems | Trade waste | Trade effluent | Commercial or industrial wastewater, under a pretreatment or FOG program |
| A capped opening for clearing a drainSee Sanitary & Drainage Systems | Inspection opening (IO) | Rodding eye; access point | Cleanout |
| The outlet valve at a basin or sinkSee Water Supply | Tap | Tap | Faucet |
| A grated pit that collects surface water into the drainsSee Stormwater Drainage | Stormwater pit; grated pit | Gully; catch pit | Catch basin; storm drain inlet |
| A pit and pumps that lift sewage up to the sewerSee Pumping Systems | Sewage pump station; sewage pit | Sewage pumping station | Lift station; sewage ejector |
Lifts and escalators
Lifts and escalators
| What it is | Australia | United Kingdom | United States |
|---|---|---|---|
| The car that carries people between floorsSee Passenger & Goods Lifts, Lift Cars & Machine Rooms | Lift | Lift | Elevator |
| A lift built to carry goodsSee Passenger & Goods Lifts | Goods lift | Goods lift | Freight elevator |
| The lift safety standardSee Passenger & Goods Lifts | AS 1735 series | BS EN 81 series, with thorough examination under LOLER | ASME A17.1 |
| A short-rise lift for wheelchair usersSee Accessibility Lifts | Low-rise platform lift | Lifting platform; platform lift | Platform lift; wheelchair lift |
| A flat or gently sloping moving belt for peopleSee Escalators & Moving Walks | Moving walk; travelator | Moving walk; travelator | Moving walk; moving walkway |
| Renewing a lift's controller, drive and doors while keeping its shaft and railsSee Passenger & Goods Lifts | Lift modernisation; lift upgrade | Lift modernisation | Elevator modernization |
Nothing matches that. Try fewer letters.