The sign calls for investigation before works can be sized. These are the 111 findings the Technical Library grades as check, across 103 elements and spaces, each with what it means for timing. Each element’s name opens its own page, where the finding sits with its causes and remedies.

Substructure

Basement, Cellars & Retaining Walls

FindingImpactWhat it means for timing
Walls without design approval; radon untested in affected areas3 ImportantAssess.

Foundations

FindingImpactWhat it means for timing
Cracks of unknown cause; trees near a building on clay3 ImportantMonitor for twelve months and investigate.

Slab on Ground

FindingImpactWhat it means for timing
Slab capacity or flatness unknown for a new use3 ImportantSurvey and assess.

Sub-floor & Crawlspace

FindingImpactWhat it means for timing
No timber pest inspection; inaccessible sub-floor3 ImportantInspect.

Superstructure

Load-Bearing Masonry

FindingImpactWhat it means for timing
Alterations with no engineering on record3 ImportantAssess.

Structural Core

FindingImpactWhat it means for timing
Lateral system unknown; seismic adequacy unassessed in seismic regions3 ImportantAssess.

Structural Frame

FindingImpactWhat it means for timing
Problem concretes possible; alterations unengineered; no survey of a car park3 ImportantAssess.

Upper Floor Slabs & Structures

FindingImpactWhat it means for timing
Design loads unknown for current or proposed use3 ImportantAssess capacity.

Façades

Architectural & Decorative Features

FindingImpactWhat it means for timing
Heritage façade over a footpath with no close-up survey on record2 PlannedClose-up hammer survey before sizing works.

Building Maintenance Units (BMU)

FindingImpactWhat it means for timing
Unit more than ten years old with no major inspection; coverage of the current façade unknown3 ImportantMajor inspection and coverage study.

Canopies & Awnings

FindingImpactWhat it means for timing
Tied awning more than ten years old with no engineer's certificate on record2 PlannedStructural inspection with opening up of anchorages.

Cladding & Wall Systems

FindingImpactWhat it means for timing
Combustible cladding identified with no order yet2 PlannedExternal wall fire risk assessment by a fire engineer sets whether and how soon it must be remediated.
Face-sealed system on framing of the at-risk era with no investigation on record2 PlannedProbe and open up before sizing works.

External Coating Systems

FindingImpactWhat it means for timing
Pre-1970 paint layers with unknown lead content; coating on concrete with unknown carbonation depth2 PlannedTest before specifying works.

Glazing Systems

FindingImpactWhat it means for timing
SSG with no adhesion test record; toughened glass at height with no heat-soak record; recurring leaks of unknown path2 PlannedTest before sizing works.

Masonry/Brickwork

FindingImpactWhat it means for timing
Tie-era cavity wall in exposed or marine position with no record of tie condition; cracks of unknown cause; damp of unknown source2 PlannedInvestigate first; size the works from what the investigation finds.

Sealants & Joints

FindingImpactWhat it means for timing
Sealants on a building of the PCB era with no hazardous materials survey2 PlannedTest before any removal; sets the method of the programme.

Verandahs, Balconies & Balustrades

FindingImpactWhat it means for timing
Balustrades below current height or with climbable rails, compliant when built; monolithic toughened glass balustrades at height3 ImportantAssess risk by use and fall height; upgrade where children use the space or where the risk warrants.

Roofs & Rainwater Goods

Chimney Stacks & Flues

FindingImpactWhat it means for timing
Working flue with no inspection record; appliance changed2 PlannedInspect and test before use.

Insulation

FindingImpactWhat it means for timing
Insulation upgrade planned without a condensation risk assessment2 PlannedAssess the build-up before the work is specified.
Possible vermiculite or spray foam with no records2 PlannedIdentify and assess first.

Plant Screens & Parapets

FindingImpactWhat it means for timing
Screens with no engineering; parapet used as roof edge protection with unknown height2 PlannedAssess.

Rainwater Systems

FindingImpactWhat it means for timing
Storm-only leaks of unknown cause; roof altered since design3 ImportantCapacity check against current rainfall data before sizing works.
Siphonic system with no maintenance records3 ImportantInspect outlets and verify the design before relying on it.
Asbestos cement gutters or downpipes of unknown status3 ImportantIdentify before any work.

Roof Coverings

FindingImpactWhat it means for timing
Sheet that may be asbestos cement, with no register entry3 ImportantIdentify by sampling before any work; it sets the method and the cost.
Water entering at a point not yet found3 ImportantInvestigate before sizing works.

Roof Safety Systems

FindingImpactWhat it means for timing
No system on a roof that needs maintenance access3 ImportantDesign the system to the work on the roof.

Roof Structure

FindingImpactWhat it means for timing
Fire-damaged members never assessed3 ImportantEngineer's assessment before reliance.
Plant or solar added with no engineering; RAAC possible from the building's era and type3 ImportantAssess before sizing works.

Skylights, Dormers & Glazed Atria

FindingImpactWhat it means for timing
Overhead glass of unknown type in an atrium2 PlannedIdentify glass type.

Waterproofing Membranes

FindingImpactWhat it means for timing
Planted or paved roof with leaks and no access to the membrane3 ImportantLocate the breach (electronic leak detection) before lifting the build-up.
Leak history on a warm roof with no moisture survey3 ImportantSurvey before choosing repair, recover or replace.
Pre-1990s bitumen felts and mastics of unknown status3 ImportantSample before cutting, coring or stripping.

Internal Areas

Bathrooms & Wet Areas

FindingImpactWhat it means for timing
Moisture readings elevated with no visible damage3 ImportantInvestigate further.

Commercial Kitchens

FindingImpactWhat it means for timing
Services capacity unknown for the current menu2 PlannedAssess.

Commercial Office Areas (Base-Build)

FindingImpactWhat it means for timing
Grade, air, light and amenities never assessed against the market2 PlannedAssess fitness for purpose.

Common Circulation Areas

FindingImpactWhat it means for timing
No fire door register; layout changes unreviewed2 PlannedSurvey.

Common Internal Areas

FindingImpactWhat it means for timing
No capital works plan or door survey2 PlannedPrepare.

Electrical & Communications Risers

FindingImpactWhat it means for timing
No capacity or fire stopping records2 PlannedSurvey.

Fireplaces

FindingImpactWhat it means for timing
Service history unknown3 ImportantService and test.

Flooring

FindingImpactWhat it means for timing
Moisture or asbestos status unknown2 PlannedTest before works.

Integrated Building Systems

FindingImpactWhat it means for timing
No integrated test since major changes2 PlannedTest.

Internal Doors & Hardware

FindingImpactWhat it means for timing
No door schedule or interface test2 PlannedSurvey.

Internal Stairwells

FindingImpactWhat it means for timing
No review of locking and re-entry2 PlannedAssess.

Internal Wall & Ceiling Finishes

FindingImpactWhat it means for timing
Hazardous content unknown in older finishes2 PlannedSample before works.

Kitchen

FindingImpactWhat it means for timing
Gas and electrical compliance unknown2 PlannedInspect.

Lift Cars & Machine Rooms

FindingImpactWhat it means for timing
Machine room conditions unknown3 ImportantAssess.

Loading Docks & Goods Handling

FindingImpactWhat it means for timing
No traffic management plan or capacity review2 PlannedAssess.

Lobbies & Atria

FindingImpactWhat it means for timing
Glass types and smoke design unknown2 PlannedAssess.

Main Entrance & Reception Areas

FindingImpactWhat it means for timing
No access audit; door safety unchecked2 PlannedAssess.

Maintenance Access Areas

FindingImpactWhat it means for timing
No access audit2 PlannedAudit.

Partitioning Systems

FindingImpactWhat it means for timing
Rated partitions not identified2 PlannedSurvey.

Plant Rooms

FindingImpactWhat it means for timing
Plant room conditions never assessed2 PlannedAssess.

Public Amenities

FindingImpactWhat it means for timing
Occupancy against fixtures unknown2 PlannedAssess.

Residential Units/Guest Rooms

FindingImpactWhat it means for timing
No unit sample inspected2 PlannedInspect.

Retail Tenancies (Base-Build)

FindingImpactWhat it means for timing
Services capacity per tenancy unknown2 PlannedSurvey.

Service Corridors

FindingImpactWhat it means for timing
Egress role of corridors not documented2 PlannedReview.

Specialised Occupancy Areas

FindingImpactWhat it means for timing
Use changed without a review of services2 PlannedAssess.

Specialist & Non-Standard Features

FindingImpactWhat it means for timing
Feature undocumented2 PlannedRecord and assess.

Storage & Archive Areas

FindingImpactWhat it means for timing
Storage loads and contents unknown2 PlannedSurvey.

External Elements

Ancillary Structures

FindingImpactWhat it means for timing
Unapproved structures; no engineering2 PlannedAssess.

Fencing, Gates & Signage

FindingImpactWhat it means for timing
No gate safety test records; signage not reviewed after changes2 PlannedInspect.

Landscaping & Irrigation

FindingImpactWhat it means for timing
No tree risk assessment2 PlannedAssess.

Pavements & Hardstand

FindingImpactWhat it means for timing
Pavement capacity for current traffic unknown2 PlannedAssess.

Recreational Facilities

FindingImpactWhat it means for timing
No inspection records2 PlannedInspect.

Stormwater Drainage

FindingImpactWhat it means for timing
No drawings; detention obligations unknown3 ImportantInvestigate.

Mechanical Services

Air Handling Units (AHUs)

FindingImpactWhat it means for timing
No hygiene inspection; outside air not measured2 PlannedInspect and measure.

Building Management & Control System (BMCS)

FindingImpactWhat it means for timing
No documentation or security assessment2 PlannedAudit.

Central Cooling Plant

FindingImpactWhat it means for timing
No tube testing, oil analysis or load study on record; capacity questioned after tenancy changes2 PlannedPlant condition and load assessment before sizing works.

Central Heating Plant

FindingImpactWhat it means for timing
No water treatment records; no assessment of heat pump readiness2 PlannedAssess before replacing.

Ductwork & Air Distribution

FindingImpactWhat it means for timing
No hygiene inspection; fire damper register incomplete2 PlannedInspect.

Heat Rejection Plant

FindingImpactWhat it means for timing
Condenser capacity in doubt on hot days2 PlannedAssess.

Localised HVAC

FindingImpactWhat it means for timing
Refrigerant type unknown; VRF compliance unknown2 PlannedInspect.

Terminal Units

FindingImpactWhat it means for timing
No sample inspection; controls data unavailable2 PlannedSample inspection and controls audit.

Ventilation Systems

FindingImpactWhat it means for timing
No records for safety-related systems2 PlannedTest and inspect.

Electrical Services

Communications, Security & Specialist Systems

FindingImpactWhat it means for timing
Line types unknown; no security assessment2 PlannedAudit.

Emergency Lighting

FindingImpactWhat it means for timing
No test records; layout not checked after fit-outs3 ImportantTest every fitting and review coverage.

Emergency Power

FindingImpactWhat it means for timing
No load bank test or load study3 ImportantTest and study.

Lighting

FindingImpactWhat it means for timing
No column testing; PCB status unknown; no lux survey2 PlannedInspect and survey.

Lighting Control System

FindingImpactWhat it means for timing
No documentation; energy data not reviewed2 PlannedAudit.

Lightning Protection

FindingImpactWhat it means for timing
No risk assessment; ESE system; no records3 ImportantAssess.

Main Electrical Supply

FindingImpactWhat it means for timing
Capacity unknown for electrification or EV charging; no recent thermography2 PlannedAssess.

Power Distribution

FindingImpactWhat it means for timing
No periodic inspection on record; wiring type unknown3 ImportantInspect and test.

Solar Photovoltaic (PV) Systems

FindingImpactWhat it means for timing
Roof structure not assessed; PPA terms unknown2 PlannedAssess.

Fire Services

Automatic Sprinkler Systems

FindingImpactWhat it means for timing
No design certificate; use changed; no recent flow test3 ImportantDesign review and testing.

Fire Detection & Alarm Systems

FindingImpactWhat it means for timing
No interface test on record; system not reviewed after fit-outs3 ImportantAudit and full integrated test.

Fire Pumping Systems

FindingImpactWhat it means for timing
No flow test record; town main pressure not checked recently3 ImportantFlow test and supply check.

Hydrant & Hose Reel Systems

FindingImpactWhat it means for timing
No flow test on record3 ImportantFlow test.

Passive Fire Protection

FindingImpactWhat it means for timing
No fire strategy; compartmentation unknown3 ImportantFire strategy and compartmentation survey.

Portable Fire Equipment

FindingImpactWhat it means for timing
No register; placement not reviewed after fit-outs3 ImportantSurvey.

Smoke Management Systems

FindingImpactWhat it means for timing
No integrated test since changes3 ImportantIntegrated test.

Specialist Suppression Systems

FindingImpactWhat it means for timing
Design basis unknown after change of use3 ImportantReview.

Hydraulic Services

Gas Services

FindingImpactWhat it means for timing
Installation never tested; alterations unrecorded3 ImportantTightness test and inspection.

Hot & Warm Water Plant

FindingImpactWhat it means for timing
No risk assessment or temperature records2 PlannedAssess.

Pumping Systems

FindingImpactWhat it means for timing
No backup power or alarm monitoring; capacity unknown2 PlannedAssess.

Sanitary & Drainage Systems

FindingImpactWhat it means for timing
No CCTV; repeated blockages of unknown cause3 ImportantSurvey.

Specialist Hydraulics

FindingImpactWhat it means for timing
No water management plan; no barrier certificate2 PlannedAssess.

Trade Waste Systems

FindingImpactWhat it means for timing
No trade waste agreement; capacity not checked after tenancy changes2 PlannedAssess.

Water Supply

FindingImpactWhat it means for timing
Pipe materials unknown; no backflow register3 ImportantSurvey.

Vertical Transportation

Accessibility Lifts

FindingImpactWhat it means for timing
No access audit; no evacuation arrangement for users3 ImportantAssess with an access consultant and the fire strategy.

Dock Levellers & Goods Hoists

FindingImpactWhat it means for timing
Forklift weights unknown; vehicle movements unknown; asbestos status unknown3 ImportantEstablish before sizing works.

Escalators & Moving Walks

FindingImpactWhat it means for timing
No audit, no injury analysis, duty unknown, asbestos status unknown3 ImportantAudit before sizing works.

Passenger & Goods Lifts

FindingImpactWhat it means for timing
No condition audit; modernisation history unknown; asbestos status unknown3 ImportantAudit before sizing works.

Building Code Compliance

Disabled Access (DDA)

FindingImpactWhat it means for timing
No access audit; alterations planned2 PlannedAudit.

Hazardous Materials

FindingImpactWhat it means for timing
Areas not accessed; refurbishment planned3 ImportantSurvey before works.

Occupational Health & Safety (OHS)

FindingImpactWhat it means for timing
No registers or building safety file3 ImportantCompile.

Environmental

Electric Vehicle (EV) Charging

FindingImpactWhat it means for timing
No capacity study; tenant or resident demand rising2 PlannedAssess capacity.

Energy Efficiency Upgrades

FindingImpactWhat it means for timing
No audit; ratings unknown2 PlannedAudit.

Sub-metering

FindingImpactWhat it means for timing
No reconciliation or metering schedule2 PlannedAudit.

Water Conservation

FindingImpactWhat it means for timing
No water audit2 PlannedAudit.